ABCA4 and MYBPC3 mini- and midigene variant sets (Riepe et al. 2021)
Proxy evidenceIndependent studyMCC (higher is better), with the other metrics below each value. The best value in each column is highlighted.
| Tool | ABCA4 noncanonical splice-site variants | ABCA4 deep-intronic variants | MYBPC3 noncanonical splice-site variants |
|---|---|---|---|
SpliceAI (Riepe et al. 2021)machine learning | 0.42 (best in column) | 0.84 (best in column) | 0.35 |
SpliceRover (Riepe et al. 2021)machine learning | 0.39 | 0.44 | 0.31 |
DSSP (Riepe et al. 2021)machine learning | 0.35 | 0.27 | 0.28 |
MMSplice (Riepe et al. 2021)machine learning | 0.24 | Not reported | 0.51 |
Spidex (Riepe et al. 2021)machine learning | 0.24 | Not reported | 0.25 |
NNSPLICE (Riepe et al. 2021)machine learning | 0.23 | 0.35 | 0.45 |
| 0.21 | 0.24 | 0.48 | |
SpliceSiteFinder-like (Riepe et al. 2021)conventional | 0.21 | 0.06 | 0.51 |
Alamut Consensus 3/4 (Riepe et al. 2021)conventional | 0.16 | 0.28 | 0.53 (best in column) |
CADD (Riepe et al. 2021)machine learning | 0.12 | 0.15 | 0.32 |
GeneSplicer (Riepe et al. 2021)machine learning | 0.03 | 0.36 | 0.51 |
R recall, P precision, Sp specificity.
Caveats and method
What each column measures:
- ABCA4 noncanonical splice-site variants: Confusion matrix, accuracy, PPV, sensitivity, specificity, NPV and MCC for up to 11 splice predictors on 71 ABCA4 noncanonical splice-site variants tested in mini- or midigene assays
- ABCA4 deep-intronic variants: Confusion matrix, accuracy, PPV, sensitivity, specificity, NPV and MCC for up to 11 splice predictors on 81 ABCA4 deep-intronic variants tested in mini- or midigene assays
- MYBPC3 noncanonical splice-site variants: Confusion matrix, accuracy, PPV, sensitivity, specificity, NPV and MCC for up to 11 splice predictors on 61 MYBPC3 noncanonical splice-site variants tested in mini- or midigene assays
- Variants were selected for testing with Alamut tools (ABCA4) or MaxEntScan (MYBPC3), which can favour those tools and their relatives.
- Cutoffs appear to be tuned on the same data set (Table 2 ROC-optimal thresholds); Tables 3-5 do not state the cutoff, so values may be optimistic.
- Small single-gene sets with strong class imbalance (ABCA4 NCSS 90% positive, ABCA4 DI 26% positive).
- Variants are from patients but splicing was measured in mini- or midigene assays in HEK293T, not in patient tissue.
- The authors note the selection bias but observed the opposite pattern (Alamut 3/4 best on MYBPC3).
- Spidex's unscored variants are counted in its confusion matrix without a stated class.
Protocols: ABCA4 noncanonical splice-site variants: classification against mini- or midigene splicing results (Riepe et al. Table 3), ABCA4 deep-intronic variants: classification against mini- or midigene splicing results (Riepe et al. Table 4), MYBPC3 noncanonical splice-site variants: classification against mini- or midigene splicing results (Riepe et al. Table 5)