HECTOR automated classifier (ENIGMA V1.2 specification)
Web-based tool that automatically populates ACMG/AMP evidence codes derivable from public data under the ENIGMA BRCA1/BRCA2 VCEP V1.2 specification and returns a five-tier classification with code-level evidence; curator-dependent evidence is routed to manual input and is not auto-assigned.
Overview
An explanatory profile has not yet been reviewed for this record.
Consult the linked sources for architecture or protocol details. Missing evidence is not evidence of a missing capability.
Model Capabilities & Hardware Requirements
Deployment facts recorded for HECTOR automated classifier (ENIGMA V1.2 specification). Fields the record does not carry are marked not recorded.
Evaluations and results
1 evaluation · 2 results. Different protocols are not a single leaderboard.
Protocol: HECTOR vs. ENIGMA Evidence Repository (eRepo) agreement · Dataset: ENIGMA Evidence Repository (eRepo) BRCA1/BRCA2 reference set
Sorted by Percent agreement (classification level) (higher is better). The best value in each column is highlighted. Decimals are rounded for display; each value links to the printed value and its source.
| Tested configuration | Percent agreement (classification level) | Percent agreement (criteria code level) |
|---|---|---|
| HECTOR automated classifier (ENIGMA V1.2 specification)Evaluation | 75.5% (108/143) | 78.9% (326/413) |
All 2 result rows with coverage, uncertainty and sources
Filter evaluations
Applied filters: All linked evaluations
| Tested configuration | Protocol and dataset | Finding | Evidence and details |
|---|---|---|---|
| Configuration: HECTOR automated classifier (ENIGMA V1.2 specification) | Protocol: HECTOR vs. ENIGMA Evidence Repository (eRepo) agreement Dataset: ENIGMA Evidence Repository (eRepo) BRCA1/BRCA2 reference set | 75.5% (108/143) Percent agreement (classification level) percent · higher Uncertainty: Not reported by the source: not reported for this endpoint Coverage: Not reported scored / Not reported eligible | Author-reported evaluation · Source checkedMethods, coverage and sourceHECTOR eRepo concordance evaluation Not reported Aggregation: Not reported HECTOR: A Web-Based Tool for Automated BRCA1/BRCA2 Variant Classification Under the ClinGen ENIGMA Specifications · Results, "Evidence Repository": "At the classification level, HECTOR agreed with the ENIGMA VCEP classification for 108 of the 143 variants (75.5%)." |
| Configuration: HECTOR automated classifier (ENIGMA V1.2 specification) | Protocol: HECTOR vs. ENIGMA Evidence Repository (eRepo) agreement Dataset: ENIGMA Evidence Repository (eRepo) BRCA1/BRCA2 reference set | 78.9% (326/413) Percent agreement (criteria code level) percent · higher Uncertainty: Not reported by the source: not reported for this endpoint Coverage: Not reported scored / Not reported eligible | Author-reported evaluation · Source checkedMethods, coverage and sourceHECTOR eRepo concordance evaluation Not reported Aggregation: Not reported HECTOR: A Web-Based Tool for Automated BRCA1/BRCA2 Variant Classification Under the ClinGen ENIGMA Specifications · Results, "Evidence Repository": "...the ENIGMA VCEP applied 413 evidence codes, of which HECTOR reproduced 326 (78.9%) at the identical code and strength (Figure 1)." |
Source checking is not independent reproduction. Release 2026-11-21-adc15377fab2.
Use this configuration
How it works, versions and access
Additional methodological details, versions and access terms have not yet been extracted into a structured profile for this configuration. Consult the linked sources and evaluation records below.
Evidence
Source checking verifies the cited claim or transcription. It does not establish independent reproduction.
Evidence table
Inspect claims, sources and review details
Trace each statement to its source and review. A context-only reference supports the record generally; it does not verify an individual field. Source checking does not reproduce an experiment.
One row per statement and cited source. Multiple citations are not independent evaluations. Shared locators are labelled explicitly.
1 evidence row matching the loaded filters
| Property and statement | Original source and location | Review and provenance |
|---|---|---|
Facets: method types1 values
| HECTOR: A Web-Based Tool for Automated BRCA1/BRCA2 Variant Classification Under the ClinGen ENIGMA Specifications HECTOR medRxiv v1, Materials and Methods, "Engine Design and ENIGMA V1.2 Implementation": evidence codes assigned against VCEP-defined thresholds and combined by ACMG/AMP rules and a point-based system; BayesDel and SpliceAI scores are inputs, HECTOR itself is not trained Version: medRxiv preprint v1, posted 2026-07-06 | conflicting claim ["source-hash-verification","automated-source-review"] · 2026-10-12 Audit detailsCorrect the method type from none to conventional_pipeline (use-case baseline review 2026-10-12, table 2). Checked as the review required. Evidence from docs/reviews/use-cases/baselines-2026-10-12.md. Independent review 2026-10-12: approved. Materials and Methods, "Engine Design and ENIGMA V1.2 Implementation": criteria applied against VCEP thresholds and decision trees, combined by ACMG/AMP rules and Tavtigian points; BayesDel and SpliceAI are inputs. No trained component. See docs/reviews/2026-10-12-method-type-corrections.md. Conflicting source claim: Field: Claim: metadata-correction-tags-20261012-26f4916fae818055ad53 Source artifact SHA-256: Hash scope: Hash scope not separately documented; inspect source record Extraction artifact SHA-256: |
Sources and history
Release 2026-11-21-adc15377fab2 · Record review: source checked
1 source record and release history
- HECTOR: A Web-Based Tool for Automated BRCA1/BRCA2 Variant Classification Under the ClinGen ENIGMA Specifications · Original source · medRxiv preprint v1, posted 2026-07-06
Technical metadata and record identifiers
Technical metadata for this record is tracked under stable ID uc-clinical-20261005-hector-v1-2-config.
Related records
How to cite
HECTOR automated classifier (ENIGMA V1.2 specification). Rewire biological model benchmark database, release 2026-11-21-adc15377fab2. https://benchmarks.rewirebio.io/database/configuration/uc-clinical-20261005-hector-v1-2-config/
Release 2026-11-21-adc15377fab2. Rankings and values change between releases, so keep the release id in the citation. Cite the original publication as well for any value you reuse: each result links its source.
The compilation and annotations made by Rewire in this release are offered under CC BY 4.0; values and text taken from cited sources stay under the terms of those sources and are not covered by this licence. Data licence