MetaSVM and MutationAssessor: Clinical likelihood ratios and balanced accuracy for 44 in silico tools against multiple large-scale functional assays of cancer susceptibility genes reverses the order
- Low severity
- Not yet reviewed
- Ordering reversal
- unknown
Clinical likelihood ratios and balanced accuracy for 44 in silico tools against multiple large-scale functional assays of cancer susceptibility genes ranks MetaSVM above MutationAssessor in 4 of 5 comparisons; 2 of 2 other studies rank MutationAssessor above MetaSVM.
An automatic lead, not a finding of error. The results below are shown as published, everywhere on the site, until a reviewer decides otherwise.
Which studies agree
3 papers rank MutationAssessor above MetaSVM in 22 of their 33 comparisons and MetaSVM higher in 10; 1 is a tie. Clinical likelihood ratios and balanced… ranks MetaSVM above MutationAssessor in 4 of its 6 comparisons and MutationAssessor higher in 1; 1 is a tie.
- Rank MutationAssessor higher (2): Livesey and Marsh 2025, An openly licensed benchmark…
- Rank MetaSVM higher (1): Clinical likelihood ratios and balanced… (disagrees)
- Mixed (1): Comprehensive assessment…
Each paper sits where at least two thirds of its comparisons point; Mixed means neither model reaches two thirds. The larger, outlined dot is the paper that disagrees.
| Paper | Role | Ranks MutationAssessor higher | Ranks MetaSVM higher | Ties |
|---|---|---|---|---|
| Clinical likelihood ratios and balanced accuracy for 44 in silico tools against multiple large-scale functional assays of cancer susceptibility genes and 1 more record · DOI | Disagrees | 1 | 4 | 1 |
| Comprehensive assessment of computational algorithms in predicting cancer driver mutations and 4 more records · DOI | Agrees | 10 | 10 | 0 |
| Livesey and Marsh 2025, Genome Biology 26:104 (Europe PMC full text XML) and 1 more record · DOI | Agrees | 7 | 0 | 0 |
| An openly licensed benchmark and per-gene calibration map for missense pathogenicity predictors on activating cancer drivers and 1 more record · DOI | Agrees | 5 | 0 | 1 |
Comparisons in Clinical likelihood ratios and balanced… (6)
Comparisons in Comprehensive assessment… (20)
Comparisons in Livesey and Marsh 2025 (7)
| Protocol | Dataset | Metric | MutationAssessor | MetaSVM | Higher |
|---|---|---|---|---|---|
| Livesey and Marsh 2025 clinical benchmark: pairwise AUROC win rate, ClinVar pathogenic versus gnomAD missense | Livesey and Marsh 2025 clinical set: ClinVar pathogenic versus gnomAD v4.1 missense (819 proteins) | Pairwise win rate (average pairwise win rate against all other VEPs, per-protein AUROC on shared variants, ClinVar P/LP versus gnomAD v4.1 missense, proteins with at least 10 of each), percent | 51.4 | 45.5 | MutationAssessor |
| Livesey and Marsh 2025 DMS benchmark: pairwise |Spearman| win rate, all 36 DMS sets | Livesey and Marsh 2025 human DMS benchmark set (36 proteins) | Pairwise win rate (average pairwise win rate against all other VEPs, |Spearman| with DMS on shared variants, 36 human DMS sets), percent | 58.8 | 39 | MutationAssessor |
| Livesey and Marsh 2025 DMS benchmark: pairwise |Spearman| win rate, all 36 DMS sets | Livesey and Marsh 2025 human DMS benchmark set (36 proteins) | Pairwise win rate (average pairwise win rate against the five top-ranked VEPs (column top_5_winrate; the five are not listed in the table), |Spearman| with DMS on shared variants, 36 human DMS sets), percent | 10.3 | 8.13 | MutationAssessor |
| Livesey and Marsh 2025 DMS benchmark: pairwise |Spearman| win rate, direct assays only | Livesey and Marsh 2025 human DMS benchmark set (36 proteins) | Pairwise win rate (average pairwise win rate against all other VEPs, |Spearman| with DMS on shared variants, direct DMS assays only), percent | 59.3 | 39.4 | MutationAssessor |
| Livesey and Marsh 2025 DMS benchmark: pairwise |Spearman| win rate, indirect assays only | Livesey and Marsh 2025 human DMS benchmark set (36 proteins) | Pairwise win rate (average pairwise win rate against all other VEPs, |Spearman| with DMS on shared variants, indirect DMS assays only), percent | 58.3 | 38.5 | MutationAssessor |
| Livesey and Marsh 2025 DMS benchmark: pairwise |Spearman| win rate, SNV-accessible substitutions only | Livesey and Marsh 2025 human DMS benchmark set (36 proteins) | Pairwise win rate (average pairwise win rate against all other VEPs, |Spearman| with DMS on shared variants, SNV-accessible substitutions only), percent | 58.8 | 39 | MutationAssessor |
| Livesey and Marsh 2025 DMS benchmark: pairwise |Spearman| win rate, SNV-accessible substitutions with gaps filled | Livesey and Marsh 2025 human DMS benchmark set (36 proteins) | Pairwise win rate (average pairwise win rate against all other VEPs, |Spearman| with DMS, SNV-accessible substitutions, missing predictions filled with the VEP's most benign score), percent | 57.3 | 39.9 | MutationAssessor |
Comparisons in An openly licensed benchmark… (6)
What disagrees
- Other studies
- rank MutationAssessor above MetaSVM in 12 of 12 comparisons
- This study
- ranks MetaSVM above MutationAssessor in 4 of 5 comparisons
- Compared
- MetaSVM, MutationAssessor
- Study that disagrees
- Clinical likelihood ratios and balanced accuracy for 44 in silico tools against multiple large-scale functional assays of cancer susceptibility genes, Cubuk et al. 2021, Supplementary tables 1-13 (41436_2021_1265_MOESM3_ESM.xlsx)
- Other studies
- An openly licensed benchmark and per-gene calibration map for missense pathogenicity predictors on activating cancer drivers, OncoCal repository, tables/tool_performance.tsv (per-tool AUROC and AUPRC by gene role), Livesey and Marsh 2025, Genome Biology 26:104 (Europe PMC full text XML), Livesey and Marsh 2025, Supplementary Material 2 (Tables S1-S8)
- Rule
- Ordering reversal; unknown
- Model identity
- Matched across studies partly through links not yet reviewed
The compared numbers
Each value links to its result record and source. Compare values within one protocol; the rule compares rankings, not raw values across protocols.
Follow-up
Current state: Not yet reviewed.
No one has reviewed this finding yet.
How to help resolve this
If you know why these studies disagree, for example a different population, metric or preprocessing step, or you have a corrected value, tell us through the contribution form. A reviewer checks every submission against its source before anything changes, and the step is added to the follow-up above.
Finding discrepancy-5fbe1b7a01480cff · All contested results · How findings are made and followed up