rewirebio.iobenchmarks
Protocol

Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5)

Per-algorithm TP, FP, FN, TPR, PPV and F1 for driver fusions on conventional RNA-seq.

12 evaluations · 72 results

Overview

An explanatory profile has not yet been reviewed for this record.

Consult the linked sources for architecture or protocol details. Missing evidence is not evidence of a missing capability.

12 recorded evaluations, 72 metric rows. A comparison chart has not yet been validated for these results. The table retains the individual findings and their sources.

View coverage and remaining gaps across all benchmarks

Results

Results are available, but no reviewed comparison panel is linked in this release.

All evaluations

12 evaluations · 72 results. Different protocols are not a single leaderboard.

Protocol: Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5) · Dataset: CCLE haematologic malignancy cell lines, conventional RNA-seq (170 cell lines)

Sorted by F1 (driver fusions, conventional RNA-seq of cell lines) (higher is better). The best value in each column is highlighted. Decimals are rounded for display; each value links to the printed value and its source.

Tested configurationF1 (driver fusions, conventional RNA-seq of cell lines)False negatives (driver fusions, conventional RNA-seq of cell lines)False positives (driver fusions, conventional RNA-seq of cell lines)Precision (driver fusions, conventional RNA-seq of cell lines)Recall (driver fusions, conventional RNA-seq of cell lines)True positives (driver fusions, conventional RNA-seq of cell lines)
Arriba v2.1.0 (Tamura et al. 2026)Evaluation1 (best in column)0 (best in column)0 (best in column)1 (best in column)1 (best in column)61 (best in column)
FusionCatcher v1.33 (Tamura et al. 2026)Evaluation0.98120.970.9860
STAR-Fusion v1.10.0 (Tamura et al. 2026)Evaluation0.9740 (best in column)1 (best in column)0.9357
Genomon v2.6.3 (Tamura et al. 2026)Evaluation0.9110 (best in column)1 (best in column)0.8250
EricScript v0.5.5 (Tamura et al. 2026)Evaluation0.89120 (best in column)1 (best in column)0.849
JAFFA-direct v2.2 (Tamura et al. 2026)Evaluation0.89850.910.8753
Pizzly v0.73.3 (Tamura et al. 2026)Evaluation0.871050.910.8451
TrinityFusion-D v0.3.4 (Tamura et al. 2026)Evaluation0.8200 (best in column)1 (best in column)0.6741
TrinityFusion-UC v0.3.4 (Tamura et al. 2026)Evaluation0.77230 (best in column)1 (best in column)0.6238
TrinityFusion-C v0.3.4 (Tamura et al. 2026)Evaluation0.76240 (best in column)1 (best in column)0.6137
InFusion v0.8 (Tamura et al. 2026)Evaluation0.6350 (best in column)1 (best in column)0.4326
STARChip v1.3e (Tamura et al. 2026)Evaluation0.58360 (best in column)1 (best in column)0.4125
All 72 result rows with coverage, uncertainty and sources
Filter evaluations

Applied filters: All linked evaluations

Exact evaluated configurations and original reported results
Tested configurationProtocol and datasetFindingEvidence and details
Configuration: Arriba v2.1.0 (Tamura et al. 2026)Protocol: Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5)
Dataset: CCLE haematologic malignancy cell lines, conventional RNA-seq (170 cell lines)
1 F1 (driver fusions, conventional RNA-seq of cell lines)
fraction · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

Arriba on driver fusions, conventional RNA-seq (Tamura et al. 2026)

rna-fusion-20261009-protocol-tamura2026-driver-conventional

Aggregation: Not reported

Comparison of gene fusion detection algorithms reveals frequently overlooked driver fusions in hematologic malignancies; Tamura et al. 2026, Supplementary Information (Supplementary Tables 1-12) · Supplementary Table 5, 'Conventional RNA-seq of cell lines', row 'Arriba', column 'F1' (PDF page text)
Configuration: Arriba v2.1.0 (Tamura et al. 2026)Protocol: Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5)
Dataset: CCLE haematologic malignancy cell lines, conventional RNA-seq (170 cell lines)
0 False negatives (driver fusions, conventional RNA-seq of cell lines)
count · lower

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

Arriba on driver fusions, conventional RNA-seq (Tamura et al. 2026)

rna-fusion-20261009-protocol-tamura2026-driver-conventional

Aggregation: Not reported

Comparison of gene fusion detection algorithms reveals frequently overlooked driver fusions in hematologic malignancies; Tamura et al. 2026, Supplementary Information (Supplementary Tables 1-12) · Supplementary Table 5, 'Conventional RNA-seq of cell lines', row 'Arriba', column 'False negative' (PDF page text)
Configuration: Arriba v2.1.0 (Tamura et al. 2026)Protocol: Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5)
Dataset: CCLE haematologic malignancy cell lines, conventional RNA-seq (170 cell lines)
0 False positives (driver fusions, conventional RNA-seq of cell lines)
count · lower

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

Arriba on driver fusions, conventional RNA-seq (Tamura et al. 2026)

rna-fusion-20261009-protocol-tamura2026-driver-conventional

Aggregation: Not reported

Comparison of gene fusion detection algorithms reveals frequently overlooked driver fusions in hematologic malignancies; Tamura et al. 2026, Supplementary Information (Supplementary Tables 1-12) · Supplementary Table 5, 'Conventional RNA-seq of cell lines', row 'Arriba', column 'False positive' (PDF page text)
Configuration: Arriba v2.1.0 (Tamura et al. 2026)Protocol: Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5)
Dataset: CCLE haematologic malignancy cell lines, conventional RNA-seq (170 cell lines)
1 Precision (driver fusions, conventional RNA-seq of cell lines)
fraction · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

Arriba on driver fusions, conventional RNA-seq (Tamura et al. 2026)

rna-fusion-20261009-protocol-tamura2026-driver-conventional

Aggregation: Not reported

Comparison of gene fusion detection algorithms reveals frequently overlooked driver fusions in hematologic malignancies; Tamura et al. 2026, Supplementary Information (Supplementary Tables 1-12) · Supplementary Table 5, 'Conventional RNA-seq of cell lines', row 'Arriba', column 'Positive predictive value' (PDF page text)
Configuration: Arriba v2.1.0 (Tamura et al. 2026)Protocol: Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5)
Dataset: CCLE haematologic malignancy cell lines, conventional RNA-seq (170 cell lines)
1 Recall (driver fusions, conventional RNA-seq of cell lines)
fraction · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

Arriba on driver fusions, conventional RNA-seq (Tamura et al. 2026)

rna-fusion-20261009-protocol-tamura2026-driver-conventional

Aggregation: Not reported

Comparison of gene fusion detection algorithms reveals frequently overlooked driver fusions in hematologic malignancies; Tamura et al. 2026, Supplementary Information (Supplementary Tables 1-12) · Supplementary Table 5, 'Conventional RNA-seq of cell lines', row 'Arriba', column 'True positive rate' (PDF page text)
Configuration: Arriba v2.1.0 (Tamura et al. 2026)Protocol: Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5)
Dataset: CCLE haematologic malignancy cell lines, conventional RNA-seq (170 cell lines)
61 True positives (driver fusions, conventional RNA-seq of cell lines)
count · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

Arriba on driver fusions, conventional RNA-seq (Tamura et al. 2026)

rna-fusion-20261009-protocol-tamura2026-driver-conventional

Aggregation: Not reported

Comparison of gene fusion detection algorithms reveals frequently overlooked driver fusions in hematologic malignancies; Tamura et al. 2026, Supplementary Information (Supplementary Tables 1-12) · Supplementary Table 5, 'Conventional RNA-seq of cell lines', row 'Arriba', column 'True positive' (PDF page text)
Configuration: EricScript v0.5.5 (Tamura et al. 2026)Protocol: Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5)
Dataset: CCLE haematologic malignancy cell lines, conventional RNA-seq (170 cell lines)
0.89 F1 (driver fusions, conventional RNA-seq of cell lines)
fraction · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

EricScript on driver fusions, conventional RNA-seq (Tamura et al. 2026)

rna-fusion-20261009-protocol-tamura2026-driver-conventional

Aggregation: Not reported

Comparison of gene fusion detection algorithms reveals frequently overlooked driver fusions in hematologic malignancies; Tamura et al. 2026, Supplementary Information (Supplementary Tables 1-12) · Supplementary Table 5, 'Conventional RNA-seq of cell lines', row 'EricScript', column 'F1' (PDF page text)
Configuration: EricScript v0.5.5 (Tamura et al. 2026)Protocol: Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5)
Dataset: CCLE haematologic malignancy cell lines, conventional RNA-seq (170 cell lines)
12 False negatives (driver fusions, conventional RNA-seq of cell lines)
count · lower

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

EricScript on driver fusions, conventional RNA-seq (Tamura et al. 2026)

rna-fusion-20261009-protocol-tamura2026-driver-conventional

Aggregation: Not reported

Comparison of gene fusion detection algorithms reveals frequently overlooked driver fusions in hematologic malignancies; Tamura et al. 2026, Supplementary Information (Supplementary Tables 1-12) · Supplementary Table 5, 'Conventional RNA-seq of cell lines', row 'EricScript', column 'False negative' (PDF page text)
Configuration: EricScript v0.5.5 (Tamura et al. 2026)Protocol: Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5)
Dataset: CCLE haematologic malignancy cell lines, conventional RNA-seq (170 cell lines)
0 False positives (driver fusions, conventional RNA-seq of cell lines)
count · lower

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

EricScript on driver fusions, conventional RNA-seq (Tamura et al. 2026)

rna-fusion-20261009-protocol-tamura2026-driver-conventional

Aggregation: Not reported

Comparison of gene fusion detection algorithms reveals frequently overlooked driver fusions in hematologic malignancies; Tamura et al. 2026, Supplementary Information (Supplementary Tables 1-12) · Supplementary Table 5, 'Conventional RNA-seq of cell lines', row 'EricScript', column 'False positive' (PDF page text)
Configuration: EricScript v0.5.5 (Tamura et al. 2026)Protocol: Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5)
Dataset: CCLE haematologic malignancy cell lines, conventional RNA-seq (170 cell lines)
1 Precision (driver fusions, conventional RNA-seq of cell lines)
fraction · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

EricScript on driver fusions, conventional RNA-seq (Tamura et al. 2026)

rna-fusion-20261009-protocol-tamura2026-driver-conventional

Aggregation: Not reported

Comparison of gene fusion detection algorithms reveals frequently overlooked driver fusions in hematologic malignancies; Tamura et al. 2026, Supplementary Information (Supplementary Tables 1-12) · Supplementary Table 5, 'Conventional RNA-seq of cell lines', row 'EricScript', column 'Positive predictive value' (PDF page text)
Configuration: EricScript v0.5.5 (Tamura et al. 2026)Protocol: Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5)
Dataset: CCLE haematologic malignancy cell lines, conventional RNA-seq (170 cell lines)
0.8 Recall (driver fusions, conventional RNA-seq of cell lines)
fraction · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

EricScript on driver fusions, conventional RNA-seq (Tamura et al. 2026)

rna-fusion-20261009-protocol-tamura2026-driver-conventional

Aggregation: Not reported

Comparison of gene fusion detection algorithms reveals frequently overlooked driver fusions in hematologic malignancies; Tamura et al. 2026, Supplementary Information (Supplementary Tables 1-12) · Supplementary Table 5, 'Conventional RNA-seq of cell lines', row 'EricScript', column 'True positive rate' (PDF page text)
Configuration: EricScript v0.5.5 (Tamura et al. 2026)Protocol: Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5)
Dataset: CCLE haematologic malignancy cell lines, conventional RNA-seq (170 cell lines)
49 True positives (driver fusions, conventional RNA-seq of cell lines)
count · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

EricScript on driver fusions, conventional RNA-seq (Tamura et al. 2026)

rna-fusion-20261009-protocol-tamura2026-driver-conventional

Aggregation: Not reported

Comparison of gene fusion detection algorithms reveals frequently overlooked driver fusions in hematologic malignancies; Tamura et al. 2026, Supplementary Information (Supplementary Tables 1-12) · Supplementary Table 5, 'Conventional RNA-seq of cell lines', row 'EricScript', column 'True positive' (PDF page text)
Configuration: FusionCatcher v1.33 (Tamura et al. 2026)Protocol: Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5)
Dataset: CCLE haematologic malignancy cell lines, conventional RNA-seq (170 cell lines)
0.98 F1 (driver fusions, conventional RNA-seq of cell lines)
fraction · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

FusionCatcher on driver fusions, conventional RNA-seq (Tamura et al. 2026)

rna-fusion-20261009-protocol-tamura2026-driver-conventional

Aggregation: Not reported

Comparison of gene fusion detection algorithms reveals frequently overlooked driver fusions in hematologic malignancies; Tamura et al. 2026, Supplementary Information (Supplementary Tables 1-12) · Supplementary Table 5, 'Conventional RNA-seq of cell lines', row 'FusionCatcher', column 'F1' (PDF page text)
Configuration: FusionCatcher v1.33 (Tamura et al. 2026)Protocol: Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5)
Dataset: CCLE haematologic malignancy cell lines, conventional RNA-seq (170 cell lines)
1 False negatives (driver fusions, conventional RNA-seq of cell lines)
count · lower

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

FusionCatcher on driver fusions, conventional RNA-seq (Tamura et al. 2026)

rna-fusion-20261009-protocol-tamura2026-driver-conventional

Aggregation: Not reported

Comparison of gene fusion detection algorithms reveals frequently overlooked driver fusions in hematologic malignancies; Tamura et al. 2026, Supplementary Information (Supplementary Tables 1-12) · Supplementary Table 5, 'Conventional RNA-seq of cell lines', row 'FusionCatcher', column 'False negative' (PDF page text)
Configuration: FusionCatcher v1.33 (Tamura et al. 2026)Protocol: Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5)
Dataset: CCLE haematologic malignancy cell lines, conventional RNA-seq (170 cell lines)
2 False positives (driver fusions, conventional RNA-seq of cell lines)
count · lower

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

FusionCatcher on driver fusions, conventional RNA-seq (Tamura et al. 2026)

rna-fusion-20261009-protocol-tamura2026-driver-conventional

Aggregation: Not reported

Comparison of gene fusion detection algorithms reveals frequently overlooked driver fusions in hematologic malignancies; Tamura et al. 2026, Supplementary Information (Supplementary Tables 1-12) · Supplementary Table 5, 'Conventional RNA-seq of cell lines', row 'FusionCatcher', column 'False positive' (PDF page text)
Configuration: FusionCatcher v1.33 (Tamura et al. 2026)Protocol: Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5)
Dataset: CCLE haematologic malignancy cell lines, conventional RNA-seq (170 cell lines)
0.97 Precision (driver fusions, conventional RNA-seq of cell lines)
fraction · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

FusionCatcher on driver fusions, conventional RNA-seq (Tamura et al. 2026)

rna-fusion-20261009-protocol-tamura2026-driver-conventional

Aggregation: Not reported

Comparison of gene fusion detection algorithms reveals frequently overlooked driver fusions in hematologic malignancies; Tamura et al. 2026, Supplementary Information (Supplementary Tables 1-12) · Supplementary Table 5, 'Conventional RNA-seq of cell lines', row 'FusionCatcher', column 'Positive predictive value' (PDF page text)
Configuration: FusionCatcher v1.33 (Tamura et al. 2026)Protocol: Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5)
Dataset: CCLE haematologic malignancy cell lines, conventional RNA-seq (170 cell lines)
0.98 Recall (driver fusions, conventional RNA-seq of cell lines)
fraction · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

FusionCatcher on driver fusions, conventional RNA-seq (Tamura et al. 2026)

rna-fusion-20261009-protocol-tamura2026-driver-conventional

Aggregation: Not reported

Comparison of gene fusion detection algorithms reveals frequently overlooked driver fusions in hematologic malignancies; Tamura et al. 2026, Supplementary Information (Supplementary Tables 1-12) · Supplementary Table 5, 'Conventional RNA-seq of cell lines', row 'FusionCatcher', column 'True positive rate' (PDF page text)
Configuration: FusionCatcher v1.33 (Tamura et al. 2026)Protocol: Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5)
Dataset: CCLE haematologic malignancy cell lines, conventional RNA-seq (170 cell lines)
60 True positives (driver fusions, conventional RNA-seq of cell lines)
count · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

FusionCatcher on driver fusions, conventional RNA-seq (Tamura et al. 2026)

rna-fusion-20261009-protocol-tamura2026-driver-conventional

Aggregation: Not reported

Comparison of gene fusion detection algorithms reveals frequently overlooked driver fusions in hematologic malignancies; Tamura et al. 2026, Supplementary Information (Supplementary Tables 1-12) · Supplementary Table 5, 'Conventional RNA-seq of cell lines', row 'FusionCatcher', column 'True positive' (PDF page text)
Configuration: Genomon v2.6.3 (Tamura et al. 2026)Protocol: Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5)
Dataset: CCLE haematologic malignancy cell lines, conventional RNA-seq (170 cell lines)
0.9 F1 (driver fusions, conventional RNA-seq of cell lines)
fraction · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Genomon on driver fusions, conventional RNA-seq (Tamura et al. 2026)

rna-fusion-20261009-protocol-tamura2026-driver-conventional

Aggregation: Not reported

Comparison of gene fusion detection algorithms reveals frequently overlooked driver fusions in hematologic malignancies; Tamura et al. 2026, Supplementary Information (Supplementary Tables 1-12) · Supplementary Table 5, 'Conventional RNA-seq of cell lines', row 'Genomon', column 'F1' (PDF page text)
Configuration: Genomon v2.6.3 (Tamura et al. 2026)Protocol: Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5)
Dataset: CCLE haematologic malignancy cell lines, conventional RNA-seq (170 cell lines)
11 False negatives (driver fusions, conventional RNA-seq of cell lines)
count · lower

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Genomon on driver fusions, conventional RNA-seq (Tamura et al. 2026)

rna-fusion-20261009-protocol-tamura2026-driver-conventional

Aggregation: Not reported

Comparison of gene fusion detection algorithms reveals frequently overlooked driver fusions in hematologic malignancies; Tamura et al. 2026, Supplementary Information (Supplementary Tables 1-12) · Supplementary Table 5, 'Conventional RNA-seq of cell lines', row 'Genomon', column 'False negative' (PDF page text)
Configuration: Genomon v2.6.3 (Tamura et al. 2026)Protocol: Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5)
Dataset: CCLE haematologic malignancy cell lines, conventional RNA-seq (170 cell lines)
0 False positives (driver fusions, conventional RNA-seq of cell lines)
count · lower

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Genomon on driver fusions, conventional RNA-seq (Tamura et al. 2026)

rna-fusion-20261009-protocol-tamura2026-driver-conventional

Aggregation: Not reported

Comparison of gene fusion detection algorithms reveals frequently overlooked driver fusions in hematologic malignancies; Tamura et al. 2026, Supplementary Information (Supplementary Tables 1-12) · Supplementary Table 5, 'Conventional RNA-seq of cell lines', row 'Genomon', column 'False positive' (PDF page text)
Configuration: Genomon v2.6.3 (Tamura et al. 2026)Protocol: Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5)
Dataset: CCLE haematologic malignancy cell lines, conventional RNA-seq (170 cell lines)
1 Precision (driver fusions, conventional RNA-seq of cell lines)
fraction · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Genomon on driver fusions, conventional RNA-seq (Tamura et al. 2026)

rna-fusion-20261009-protocol-tamura2026-driver-conventional

Aggregation: Not reported

Comparison of gene fusion detection algorithms reveals frequently overlooked driver fusions in hematologic malignancies; Tamura et al. 2026, Supplementary Information (Supplementary Tables 1-12) · Supplementary Table 5, 'Conventional RNA-seq of cell lines', row 'Genomon', column 'Positive predictive value' (PDF page text)
Configuration: Genomon v2.6.3 (Tamura et al. 2026)Protocol: Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5)
Dataset: CCLE haematologic malignancy cell lines, conventional RNA-seq (170 cell lines)
0.82 Recall (driver fusions, conventional RNA-seq of cell lines)
fraction · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Genomon on driver fusions, conventional RNA-seq (Tamura et al. 2026)

rna-fusion-20261009-protocol-tamura2026-driver-conventional

Aggregation: Not reported

Comparison of gene fusion detection algorithms reveals frequently overlooked driver fusions in hematologic malignancies; Tamura et al. 2026, Supplementary Information (Supplementary Tables 1-12) · Supplementary Table 5, 'Conventional RNA-seq of cell lines', row 'Genomon', column 'True positive rate' (PDF page text)
Configuration: Genomon v2.6.3 (Tamura et al. 2026)Protocol: Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5)
Dataset: CCLE haematologic malignancy cell lines, conventional RNA-seq (170 cell lines)
50 True positives (driver fusions, conventional RNA-seq of cell lines)
count · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Genomon on driver fusions, conventional RNA-seq (Tamura et al. 2026)

rna-fusion-20261009-protocol-tamura2026-driver-conventional

Aggregation: Not reported

Comparison of gene fusion detection algorithms reveals frequently overlooked driver fusions in hematologic malignancies; Tamura et al. 2026, Supplementary Information (Supplementary Tables 1-12) · Supplementary Table 5, 'Conventional RNA-seq of cell lines', row 'Genomon', column 'True positive' (PDF page text)
Configuration: InFusion v0.8 (Tamura et al. 2026)Protocol: Driver fusions, conventional RNA-seq of haematologic cell lines, validated truth (Tamura et al. 2026 Supplementary Table 5)
Dataset: CCLE haematologic malignancy cell lines, conventional RNA-seq (170 cell lines)
0.6 F1 (driver fusions, conventional RNA-seq of cell lines)
fraction · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

InFusion on driver fusions, conventional RNA-seq (Tamura et al. 2026)

rna-fusion-20261009-protocol-tamura2026-driver-conventional

Aggregation: Not reported

Comparison of gene fusion detection algorithms reveals frequently overlooked driver fusions in hematologic malignancies; Tamura et al. 2026, Supplementary Information (Supplementary Tables 1-12) · Supplementary Table 5, 'Conventional RNA-seq of cell lines', row 'InFusion', column 'F1' (PDF page text)

Source checking is not independent reproduction. Release 2026-11-21-adc15377fab2.

Methods and evaluation design

Procedure, tasks and evaluated configurations

Recorded evaluations

Each evaluation records what was tested and under which conditions.

Baseline coverage

Reference methods help show what a model adds beyond simple controls. We track a null control and a conventional method for each protocol.

0 of 2 active baseline roles have published Rewire measurements in this release. Measurements on a selected protocol do not establish coverage of an entire suite.

No execution recipe linked to this protocol. Recipe availability does not establish a completed evaluation.

Author-reported evaluations
1
External evaluations
11

Literature evidence is not a Rewire measurement. Executed but unpublished runs and private review status are not included.

Null control

Proposed control: requires review

Select a task-valid null control after reviewing inputs and metric

Protocol-specific applicability, permitted inputs, access, split, evaluator and execution requirements need review before implementation or execution.

This is a suggested selection rule, not a validated method or a measured score.

Conventional reference

Proposed control: requires review

Select an upstream conventional reference after reviewing the full protocol

Protocol-specific applicability, permitted inputs, access, split, evaluator and execution requirements need review before implementation or execution.

This is a suggested selection rule, not a validated method or a measured score.

Protocol coverage CSV (gzip) · Model evaluation matrix (gzip) · Source table (gzip) · Release and checksums (gzip)

Coverage is derived from release 2026-11-21-adc15377fab2. Source citations describe the original records; they do not validate an unreviewed baseline proposal. No results have been generated by this audit.

Run instructions

No runnable recipe has been reviewed for this protocol. Dataset access, model requirements, licences and compute requirements must be checked against its sources before execution.

Evidence

Source checking verifies the cited claim or transcription. It does not establish independent reproduction.

Evidence table

Inspect claims, sources and review details

Trace each statement to its source and review. A context-only reference supports the record generally; it does not verify an individual field. Source checking does not reproduce an experiment.

One row per statement and cited source. Multiple citations are not independent evaluations. Shared locators are labelled explicitly.

0 evidence rows matching the loaded filters

Claims, original sources and review scope · Release 2026-11-21-adc15377fab2
Property and statementOriginal source and locationReview and provenance

No evidence rows match these filters. Choose another scope or clear the search.

Sources and history

Release 2026-11-21-adc15377fab2 · Record review: source checked

2 source records and release historyDownload this release (gzip)
Technical metadata and record identifiers

Technical metadata for this record is tracked under stable ID rna-fusion-20261009-protocol-tamura2026-driver-conventional.

Source locator: Supplementary Table 5, sub-table 'Conventional RNA-seq of cell lines'; Methods 'Comparison of detection algorithms'

Related records

Suggest a correction