rewirebio.iobenchmarks

Use caseMetabolomicsResearch only

Shortlist molecular identities from tandem mass spectra

Which retrieval configurations merit validation when molecular formula is unknown and a researcher can examine only a short list of candidate structures?

What the evidence shows

Two preprints report formula-free retrieval of the true structure from mass-matched PubChem candidates for MassSpecGym spectra, and their values are not directly comparable.

In the MSAlign preprint, MSAlign ranks first among the formula-free methods on every split the paper reports, but its top-1 recall falls from about half on the formula split to under a fifth on the MCES split. On the MassSpecGym formula split, Recall@1 was 47.5 for MSAlign and 58.2 with score fusion, against 42.7 for Emb-Cos, 13.9 for JESTR and 4.7 for DeepSet, with standard deviations of 0.5 to 3.4 over three random splitting seeds. On the MCES split the order is the same but the values are much lower: 19.0, 30.8, 12.6, 7.9 and 1.9; the table caption describes three splits there too, but the methods describe two swapped variants.

Recall@20 reaches 87.0 for MSAlign and 92.8 with score fusion on the formula split, and 64.9 and 82.0 on MCES. An earlier version of the same paper reports Recall@1 of 53.8 for MSAlign and 41.2 for Emb-Cos on the formula split, so the two versions differ and are not independent measurements. These MSAlign values assume the true structure is among 256 mass-matched candidates and were scored by the MSAlign authors.

MassSpecGym in the Wild, whose authors include the developers of MIST, MIST-CF and MassSpecGym, reports two formula-free configurations that it does not flag for formula leakage, on the MassSpecGym test fold with up to 256 mass-matched candidates per spectrum. MIST given the top formula predicted by MIST-CF found the true structure at rank 1 for 26.64 percent of test spectra and within the top 20 for 54.90 percent, against 0.43 and 7.99 percent for random ranking. Its candidate pool and split differ from MSAlign's, and the MIST score depends on the formula annotator as well as the retriever.

All of these values are reported by the authors of preprints, and none measures open-world identification, because the true structure is always among the candidates.

You bring
  • MS/MS spectra with metadata sufficient to derive neutral molecular mass
  • A frozen set of candidate molecular structures; the true identity must be present for the measured retrieval endpoint
You want
Split-specific Recall@1 and Recall@20 evidence for six exact configurations, plus candidate-pool and domain-shift limits.
Evidence in this release
8 comparisons shown · 9 tools · 13 configurations
Kept up to date
Evidence last checked 7 October 2026 · re-checked monthly, next due 7 November 2026

Baseline

MassSpecGym DeepSets fingerprint baseline. No pre-machine-learning retrieval method, such as spectral library search, is measured in the linked evidence, so the reference is the benchmark's own DeepSets fingerprint predictor: a small trained network that ranks candidates by predicted-fingerprint similarity. The only non-learned rows are random rankings of the candidate list, a chance-level control rather than a method to beat.

Machine-learning methods are compared with the baseline on the same data in 3 tables: MSAlign v2 retrieval: massspecgym-mces-formula-free, MSAlign v2 retrieval: massspecgym-formula-formula-free, MSAlign v2 retrieval: spectraverse-formula-free. Baseline rows are marked in each table.

Tools compared

Comparisons

Each table is one study or protocol with its own truth set and scoring. Compare tools within a table, not across tables.

MSAlign v2 retrieval: massspecgym-mces-formula-free

Proxy evidenceAuthor-reported

Formula-free candidate Recall@1, @5 and @20: massspecgym-mces

Sorted by Top-1 accuracy (higher is better). The best value in each column is highlighted.

Scroll sideways to see all 3 columns.

ToolTop-1 accuracy (retrieval)Top-20 accuracy (retrieval)Top-5 accuracy (retrieval)
MSAlign score fusion (overbar)foundation model30.8% ± 2.5 (best in column)82.0% ± 0.8 (best in column)59.3% ± 0.7 (best in column)
MSAlignfoundation model19.0% ± 3.264.9% ± 0.941.2% ± 2.5
Emb-Cosmachine learning12.6% ± 0.251.6% ± 0.929.9% ± 0.2
JESTRmachine learning7.9% ± 1.144.8% ± 1.922.3% ± 1.4
DeepSetBaselinemachine learning1.9% ± 0.521.8% ± 1.48.4% ± 0.6

± is a standard deviation.

Caveats and method
  • Requires true structure among 256 candidates; not open-world identification.
  • MCES uses two split variants per methods, in conflict with generic three-split caption.
  • Separate v2 implementation and split summary from v1 measurements.
  • No instrument-specific prospective success, calibration or clinical validity.

Protocol: MSAlign v2 retrieval: massspecgym-mces-formula-free

MSAlign v2 retrieval: massspecgym-formula-formula-free

Proxy evidenceAuthor-reported

Formula-free candidate Recall@1, @5 and @20: massspecgym-formula

Sorted by Top-1 accuracy (higher is better). The best value in each column is highlighted.

Scroll sideways to see all 3 columns.

ToolTop-1 accuracy (retrieval)Top-20 accuracy (retrieval)Top-5 accuracy (retrieval)
MSAlign score fusion (overbar)foundation model58.2% ± 3.4 (best in column)92.8% ± 1.1 (best in column)80.7% ± 3.0 (best in column)
MSAlignfoundation model47.5% ± 3.487.0% ± 1.171.3% ± 2.6
Emb-Cosmachine learning42.7% ± 3.080.4% ± 1.665.2% ± 2.8
JESTRmachine learning13.9% ± 0.557.0% ± 0.732.5% ± 0.8
DeepSetBaselinemachine learning4.7% ± 0.627.5% ± 2.013.0% ± 1.3

± is a standard deviation.

Caveats and method
  • Requires true structure among 256 candidates; not open-world identification.
  • Three split seeds; not independently reproduced.
  • Separate v2 implementation and split summary from v1 measurements.
  • No instrument-specific prospective success, calibration or clinical validity.

Protocol: MSAlign v2 retrieval: massspecgym-formula-formula-free

MSAlign v2 retrieval: spectraverse-formula-free

Proxy evidenceAuthor-reported

Formula-free candidate Recall@1, @5 and @20: spectraverse

Sorted by Top-1 accuracy (higher is better). The best value in each column is highlighted.

Scroll sideways to see all 3 columns.

ToolTop-1 accuracy (retrieval)Top-20 accuracy (retrieval)Top-5 accuracy (retrieval)
MSAlign score fusion (overbar)foundation model41.3% ± 2.7 (best in column)85.4% ± 0.9 (best in column)68.3% ± 1.7 (best in column)
MSAlignfoundation model31.8% ± 2.678.3% ± 1.758.2% ± 1.9
Emb-Cosmachine learning26.6% ± 1.971.0% ± 1.349.5% ± 1.0
JESTRmachine learning5.4% ± 0.239.4% ± 2.017.5% ± 1.3
DeepSetBaselinemachine learning2.0% ± 0.422.9% ± 0.98.4% ± 1.0

± is a standard deviation.

Caveats and method
  • Requires true structure among 256 candidates; not open-world identification.
  • Three split seeds; not independently reproduced.
  • Separate v2 implementation and split summary from v1 measurements.
  • No instrument-specific prospective success, calibration or clinical validity.

Protocol: MSAlign v2 retrieval: spectraverse-formula-free

MassSpecGym in the Wild, mass-based retrieval (Table 2)

Proxy evidenceAuthor-reported

Top-1 accuracy (higher is better), with the other metrics below each value. The best value in each column is highlighted.

Scroll sideways to see all 2 columns.

ToolHit rate@1Hit rate@20
MIST (MIST-CF top-1 formula)machine learning26.64% (25.53–27.75) (best in column)Not reportedTop-20 accuracy 54.90% (53.69–56.06)
Randomconventional0.43% (0.29-0.61)Not reportedTop-20 accuracy 7.99% (7.34-8.74)

Ranges in brackets are confidence intervals.

Caveats and method

What each column measures:

  • Hit rate@1: Hit rate@1 (mean over MassSpecGym test spectra, 99.9% bootstrap CI) for ranking the true structure among mass-matched PubChem candidates
  • Hit rate@20: Hit rate@20 (mean over MassSpecGym test spectra, 99.9% bootstrap CI) for ranking the true structure among mass-matched PubChem candidates
  • Authors include the MIST, MIST-CF and MassSpecGym developers (author_reported).
  • Preprint (arXiv:2606.19624v1).
  • The true structure must be in the candidate set; not open-world identification.
  • Retrieval inherits the errors of the formula annotator; its formula accuracy is in Table 7, not extracted.
  • Table 8 reports a further non-grey variant (MIST-CF top-5 formulas, element-wise max), not extracted.
  • Values are percentages printed without a percent sign in Table 2.

Protocols: MassSpecGym mass-based retrieval, Hit rate@1 (MassSpecGym in the Wild Table 2), MassSpecGym mass-based retrieval, Hit rate@20 (MassSpecGym in the Wild Table 2)

MSAlign molecular retrieval MassSpecGym formula split: no formula, R@1: MassSpecGym formula split retrieval with no formula

Proxy evidenceAuthor-reportedIndependent study

Recall@1 of the true molecular structure among 256 mass-matched candidate structures on the MassSpecGym formula split, with no molecular formula supplied.

Sorted by Top-1 accuracy (higher is better). The best value in each column is highlighted.

ToolTop-1 accuracy (retrieval)
MSAlignfoundation model53.8% (best in column)
Emb-Cosmachine learning41.2%
SAILmachine learning29.5%
DeepSetsmachine learning22.2%
JESTRmachine learning20.0%
FFNmachine learning16.9%
Caveats and method
  • The correct structure must be in a 256-candidate mass-filtered pool. Scores do not transfer automatically to a larger database, a different pool-construction procedure or a missing true structure.
  • MCES and formula splits impose different distribution shifts. The source authors favour formula splits for their deployment interpretation; that choice does not prove that formula-split performance represents every intended application.
  • Reported methods are the paper implementations: DeepSets training was extended to 50 epochs. These are not interchangeable with original model-paper scores or current checkpoints.
  • Exact test denominators, split-manifest hashes, checkpoint hashes and evaluator revisions remain unextracted or unreported in the catalogue. No uncertainty values or new independent reproduction are established.
  • Candidate recall is not an authenticated metabolite identification, a clinical diagnosis or a calibrated probability. Human domain review remains outstanding.

Protocol: MSAlign molecular retrieval MassSpecGym formula split: no formula, R@1: MassSpecGym formula split retrieval with no formula

MSAlign molecular retrieval MassSpecGym formula split: no formula, R@20: MassSpecGym formula split retrieval with no formula

Proxy evidenceAuthor-reportedIndependent study

Recall@20 of the true molecular structure among 256 mass-matched candidate structures on the MassSpecGym formula split, with no molecular formula supplied.

Sorted by Top-20 accuracy (higher is better). The best value in each column is highlighted.

ToolTop-20 accuracy (retrieval)
MSAlignfoundation model87.1% (best in column)
Emb-Cosmachine learning79.6%
SAILmachine learning73.0%
JESTRmachine learning60.9%
DeepSetsmachine learning50.9%
FFNmachine learning40.4%
Caveats and method
  • The correct structure must be in a 256-candidate mass-filtered pool. Scores do not transfer automatically to a larger database, a different pool-construction procedure or a missing true structure.
  • MCES and formula splits impose different distribution shifts. The source authors favour formula splits for their deployment interpretation; that choice does not prove that formula-split performance represents every intended application.
  • Reported methods are the paper implementations: DeepSets training was extended to 50 epochs. These are not interchangeable with original model-paper scores or current checkpoints.
  • Exact test denominators, split-manifest hashes, checkpoint hashes and evaluator revisions remain unextracted or unreported in the catalogue. No uncertainty values or new independent reproduction are established.
  • Candidate recall is not an authenticated metabolite identification, a clinical diagnosis or a calibrated probability. Human domain review remains outstanding.

Protocol: MSAlign molecular retrieval MassSpecGym formula split: no formula, R@20: MassSpecGym formula split retrieval with no formula

MSAlign molecular retrieval MassSpecGym MCES split: no formula, R@1: MassSpecGym MCES split retrieval with no formula

Proxy evidenceAuthor-reportedIndependent study

Recall@1 of the true molecular structure among 256 mass-matched candidate structures on the MassSpecGym MCES split, with no molecular formula supplied.

Sorted by Top-1 accuracy (higher is better). The best value in each column is highlighted.

ToolTop-1 accuracy (retrieval)
MSAlignfoundation model16.20% (best in column)
Emb-Cosmachine learning12.30%
JESTRmachine learning11.80%
SAILmachine learning9.50%
DeepSetsmachine learning5.24%
FFNmachine learning2.54%
Caveats and method
  • The correct structure must be in a 256-candidate mass-filtered pool. Scores do not transfer automatically to a larger database, a different pool-construction procedure or a missing true structure.
  • MCES and formula splits impose different distribution shifts. The source authors favour formula splits for their deployment interpretation; that choice does not prove that formula-split performance represents every intended application.
  • Reported methods are the paper implementations: DeepSets training was extended to 50 epochs. These are not interchangeable with original model-paper scores or current checkpoints.
  • Exact test denominators, split-manifest hashes, checkpoint hashes and evaluator revisions remain unextracted or unreported in the catalogue. No uncertainty values or new independent reproduction are established.
  • Candidate recall is not an authenticated metabolite identification, a clinical diagnosis or a calibrated probability. Human domain review remains outstanding.

Protocol: MSAlign molecular retrieval MassSpecGym MCES split: no formula, R@1: MassSpecGym MCES split retrieval with no formula

MSAlign molecular retrieval MassSpecGym MCES split: no formula, R@20: MassSpecGym MCES split retrieval with no formula

Proxy evidenceAuthor-reportedIndependent study

Recall@20 of the true molecular structure among 256 mass-matched candidate structures on the MassSpecGym MCES split, with no molecular formula supplied.

Sorted by Top-20 accuracy (higher is better). The best value in each column is highlighted.

ToolTop-20 accuracy (retrieval)
MSAlignfoundation model59.90% (best in column)
JESTRmachine learning49.70%
Emb-Cosmachine learning46.40%
SAILmachine learning45.20%
DeepSetsmachine learning28.21%
FFNmachine learning20.00%
Caveats and method
  • The correct structure must be in a 256-candidate mass-filtered pool. Scores do not transfer automatically to a larger database, a different pool-construction procedure or a missing true structure.
  • MCES and formula splits impose different distribution shifts. The source authors favour formula splits for their deployment interpretation; that choice does not prove that formula-split performance represents every intended application.
  • Reported methods are the paper implementations: DeepSets training was extended to 50 epochs. These are not interchangeable with original model-paper scores or current checkpoints.
  • Exact test denominators, split-manifest hashes, checkpoint hashes and evaluator revisions remain unextracted or unreported in the catalogue. No uncertainty values or new independent reproduction are established.
  • Candidate recall is not an authenticated metabolite identification, a clinical diagnosis or a calibrated probability. Human domain review remains outstanding.

Protocol: MSAlign molecular retrieval MassSpecGym MCES split: no formula, R@20: MassSpecGym MCES split retrieval with no formula

Not covered yet

  • The correct structure must be in a 256-candidate mass-filtered pool. Scores do not transfer automatically to a larger database, a different pool-construction procedure or a missing true structure.
  • MCES and formula splits impose different distribution shifts. The source authors favour formula splits for their deployment interpretation; that choice does not prove that formula-split performance represents every intended application.
  • Reported methods are the paper implementations: DeepSets training was extended to 50 epochs. These are not interchangeable with original model-paper scores or current checkpoints.
  • Exact test denominators, split-manifest hashes, checkpoint hashes and evaluator revisions remain unextracted or unreported in the catalogue. No uncertainty values or new independent reproduction are established.
  • Candidate recall is not an authenticated metabolite identification, a clinical diagnosis or a calibrated probability. Human domain review remains outstanding.
  • The four metric and split groups come from one paper and do not constitute independent replications.
  • 30 September 2026 audit: v1 source record labels 2605.19752v1 but uses an unversioned URL that now serves v2; old source bytes/values must remain immutable. v1-specific URL returned HTTP406 during this audit.
  • 30 September 2026 audit: For MCES, the v2 Table3 generic caption says three random splits, but Section5.1 explicitly uses two validation/test-swapped variants; the discrepancy is preserved.
  • 30 September 2026 audit: Benchmark assumes the true structure is present among 256 neutral-mass-matched candidates. Unknown candidates, instrument-specific prospective performance and authenticated identification remain gaps.

Contribute evidence or propose a correction

Question, sources and review

Who this is for, setting and exclusions

Compare formula-free retrieval configurations within a named split and shortlist size, then validate the intended instrument, chemistry and candidate database before selecting a workflow.

Who this is for
  • Metabolomics researchers shortlisting candidate molecular identities for experimental confirmation
  • Computational researchers choosing retrieval inputs, candidate pools and validation splits
Biological setting
MSAlign paper Table 3, MassSpecGym formula and MCES splits, formula-free inputs. Each source candidate pool contains 256 mass-matched PubChem structures. Formula and MCES splits remain distinct.
Research setting
Research only. Candidate retrieval is not a confirmed molecular identification or evidence of clinical diagnostic performance.

Outside this use case

  • De novo molecular generation or cases where the true structure is absent from the candidate set
  • Formula-conditioned retrieval, including MIST, FLARE and MSAlign+Filter
  • Pooling split-specific results or transferring scores to different candidate database sizes
  • Authenticated molecular identification and clinical diagnosis
Sources, review and downloads

Automated source review · 2026-09-30 · Codex source curation, independent worker cross-review and root integration review

Source-backed literature curation with independent automated transcription and scope checks. No new model execution, independent experimental replication, qualified human scientific review or clinical validation.

Release 2026-11-02-a7f03c9e55a5 · question use-case-mass-spectrum-molecule-shortlisting

Use-case input digest 43a80aef5473f1a49c013b6d46b720b850ff5a0d18dcbb741dcdeed1ed082db1