rewirebio.iobenchmarks
Configuration

NeuSomatic 0.2.1 (Guille et al. 2025)

NeuSomatic 0.2.1: NeuSomatic_v0.1.4_standalone_SEQC-WGS-GT50-SpikeWGS10.pth; Paired tumour-normal WES calling restricted to target regions.

2 evaluations · 12 results1 open disagreement between studies involves its model

Overview

An explanatory profile has not yet been reviewed for this record.

Consult the linked sources for architecture or protocol details. Missing evidence is not evidence of a missing capability.

Model Capabilities & Hardware Requirements

Deployment facts recorded for NeuSomatic 0.2.1 (Guille et al. 2025). Fields the record does not carry are marked not recorded.

ParametersNot recorded
Minimum VRAMNot recorded
Inference LatencyNot recorded
Context WindowNot recorded
AccessNot recorded
LicenseNot recorded

Evaluated Checkpoint: 0.2.1

Evaluations and results

2 evaluations · 12 results. Different protocols are not a single leaderboard.

Dataset: SEQC2 HCC1395/HCC1395BL WES, Fudan replicate (WES_FD_T_1), high-confidence regions

Sorted by F1 (indel only) (higher is better). The best value in each column is highlighted. Decimals are rounded for display; each value links to the printed value and its source.

Tested configurationProtocol and datasetF1 (indel only)F1 (SNV only)False positive rate (indel only)False positive rate (SNV only)False positives (indel only)False positives (SNV only)Precision (indel only)Precision (SNV only)Recall (indel only)Recall (SNV only)True positives (indel only)True positives (SNV only)
NeuSomatic 0.2.1 (Guille et al. 2025)EvaluationSEQC2 HCC1395 WES validation sample, somatic indels (Guille et al. 2025 Table S7)0.472Not reported3.32e-8Not reported5Not reported0.773Not reported0.34Not reported17Not reported
NeuSomatic 0.2.1 (Guille et al. 2025)EvaluationSEQC2 HCC1395 WES validation sample, somatic SNVs (Guille et al. 2025 Table S7)Not reported0.835Not reported1.39e-7Not reported21Not reported0.976Not reported0.729Not reported846
All 12 result rows with coverage, uncertainty and sources
Filter evaluations

Applied filters: All linked evaluations

Exact evaluated configurations and original reported results
Tested configurationProtocol and datasetFindingEvidence and details
Configuration: NeuSomatic 0.2.1 (Guille et al. 2025)Protocol: SEQC2 HCC1395 WES validation sample, somatic indels (Guille et al. 2025 Table S7)
Dataset: SEQC2 HCC1395/HCC1395BL WES, Fudan replicate (WES_FD_T_1), high-confidence regions
0.472 F1 (indel only)
fraction · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

NeuSomatic on SEQC2 HCC1395 WES validation indels (Guille et al. 2025)

somatic-20261009-protocol-guille2025-seqc2-fd-wes-indel

Aggregation: Not reported

A benchmarking study of individual somatic variant callers and voting-based ensembles for whole-exome sequencing; Guille et al. 2025, Supplementary Table S7 (validation dataset) · Supplementary Table S7 (tables7_bbae697.xls, sheet 'Results'), H33; Tools 'NeuSomatic'; column 'F1'
Configuration: NeuSomatic 0.2.1 (Guille et al. 2025)Protocol: SEQC2 HCC1395 WES validation sample, somatic indels (Guille et al. 2025 Table S7)
Dataset: SEQC2 HCC1395/HCC1395BL WES, Fudan replicate (WES_FD_T_1), high-confidence regions
5 False positives (indel only)
count · lower

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

NeuSomatic on SEQC2 HCC1395 WES validation indels (Guille et al. 2025)

somatic-20261009-protocol-guille2025-seqc2-fd-wes-indel

Aggregation: Not reported

A benchmarking study of individual somatic variant callers and voting-based ensembles for whole-exome sequencing; Guille et al. 2025, Supplementary Table S7 (validation dataset) · Supplementary Table S7 (tables7_bbae697.xls, sheet 'Results'), E33; Tools 'NeuSomatic'; column 'FP'
Configuration: NeuSomatic 0.2.1 (Guille et al. 2025)Protocol: SEQC2 HCC1395 WES validation sample, somatic indels (Guille et al. 2025 Table S7)
Dataset: SEQC2 HCC1395/HCC1395BL WES, Fudan replicate (WES_FD_T_1), high-confidence regions
3.32e-8 False positive rate (indel only)
fraction · lower

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

NeuSomatic on SEQC2 HCC1395 WES validation indels (Guille et al. 2025)

somatic-20261009-protocol-guille2025-seqc2-fd-wes-indel

Aggregation: Not reported

A benchmarking study of individual somatic variant callers and voting-based ensembles for whole-exome sequencing; Guille et al. 2025, Supplementary Table S7 (validation dataset) · Supplementary Table S7 (tables7_bbae697.xls, sheet 'Results'), G33; Tools 'NeuSomatic'; column 'FPR'
Configuration: NeuSomatic 0.2.1 (Guille et al. 2025)Protocol: SEQC2 HCC1395 WES validation sample, somatic indels (Guille et al. 2025 Table S7)
Dataset: SEQC2 HCC1395/HCC1395BL WES, Fudan replicate (WES_FD_T_1), high-confidence regions
0.773 Precision (indel only)
fraction · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

NeuSomatic on SEQC2 HCC1395 WES validation indels (Guille et al. 2025)

somatic-20261009-protocol-guille2025-seqc2-fd-wes-indel

Aggregation: Not reported

A benchmarking study of individual somatic variant callers and voting-based ensembles for whole-exome sequencing; Guille et al. 2025, Supplementary Table S7 (validation dataset) · Supplementary Table S7 (tables7_bbae697.xls, sheet 'Results'), I33; Tools 'NeuSomatic'; column 'PPV'
Configuration: NeuSomatic 0.2.1 (Guille et al. 2025)Protocol: SEQC2 HCC1395 WES validation sample, somatic indels (Guille et al. 2025 Table S7)
Dataset: SEQC2 HCC1395/HCC1395BL WES, Fudan replicate (WES_FD_T_1), high-confidence regions
0.34 Recall (indel only)
fraction · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

NeuSomatic on SEQC2 HCC1395 WES validation indels (Guille et al. 2025)

somatic-20261009-protocol-guille2025-seqc2-fd-wes-indel

Aggregation: Not reported

A benchmarking study of individual somatic variant callers and voting-based ensembles for whole-exome sequencing; Guille et al. 2025, Supplementary Table S7 (validation dataset) · Supplementary Table S7 (tables7_bbae697.xls, sheet 'Results'), F33; Tools 'NeuSomatic'; column 'TPR'
Configuration: NeuSomatic 0.2.1 (Guille et al. 2025)Protocol: SEQC2 HCC1395 WES validation sample, somatic indels (Guille et al. 2025 Table S7)
Dataset: SEQC2 HCC1395/HCC1395BL WES, Fudan replicate (WES_FD_T_1), high-confidence regions
17 True positives (indel only)
count · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

NeuSomatic on SEQC2 HCC1395 WES validation indels (Guille et al. 2025)

somatic-20261009-protocol-guille2025-seqc2-fd-wes-indel

Aggregation: Not reported

A benchmarking study of individual somatic variant callers and voting-based ensembles for whole-exome sequencing; Guille et al. 2025, Supplementary Table S7 (validation dataset) · Supplementary Table S7 (tables7_bbae697.xls, sheet 'Results'), D33; Tools 'NeuSomatic'; column 'TP'
Configuration: NeuSomatic 0.2.1 (Guille et al. 2025)Protocol: SEQC2 HCC1395 WES validation sample, somatic SNVs (Guille et al. 2025 Table S7)
Dataset: SEQC2 HCC1395/HCC1395BL WES, Fudan replicate (WES_FD_T_1), high-confidence regions
0.835 F1 (SNV only)
fraction · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

NeuSomatic on SEQC2 HCC1395 WES validation SNVs (Guille et al. 2025)

somatic-20261009-protocol-guille2025-seqc2-fd-wes-snv

Aggregation: Not reported

A benchmarking study of individual somatic variant callers and voting-based ensembles for whole-exome sequencing; Guille et al. 2025, Supplementary Table S7 (validation dataset) · Supplementary Table S7 (tables7_bbae697.xls, sheet 'Results'), H18; Tools 'NeuSomatic'; column 'F1'
Configuration: NeuSomatic 0.2.1 (Guille et al. 2025)Protocol: SEQC2 HCC1395 WES validation sample, somatic SNVs (Guille et al. 2025 Table S7)
Dataset: SEQC2 HCC1395/HCC1395BL WES, Fudan replicate (WES_FD_T_1), high-confidence regions
21 False positives (SNV only)
count · lower

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

NeuSomatic on SEQC2 HCC1395 WES validation SNVs (Guille et al. 2025)

somatic-20261009-protocol-guille2025-seqc2-fd-wes-snv

Aggregation: Not reported

A benchmarking study of individual somatic variant callers and voting-based ensembles for whole-exome sequencing; Guille et al. 2025, Supplementary Table S7 (validation dataset) · Supplementary Table S7 (tables7_bbae697.xls, sheet 'Results'), E18; Tools 'NeuSomatic'; column 'FP'
Configuration: NeuSomatic 0.2.1 (Guille et al. 2025)Protocol: SEQC2 HCC1395 WES validation sample, somatic SNVs (Guille et al. 2025 Table S7)
Dataset: SEQC2 HCC1395/HCC1395BL WES, Fudan replicate (WES_FD_T_1), high-confidence regions
1.39e-7 False positive rate (SNV only)
fraction · lower

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

NeuSomatic on SEQC2 HCC1395 WES validation SNVs (Guille et al. 2025)

somatic-20261009-protocol-guille2025-seqc2-fd-wes-snv

Aggregation: Not reported

A benchmarking study of individual somatic variant callers and voting-based ensembles for whole-exome sequencing; Guille et al. 2025, Supplementary Table S7 (validation dataset) · Supplementary Table S7 (tables7_bbae697.xls, sheet 'Results'), G18; Tools 'NeuSomatic'; column 'FPR'
Configuration: NeuSomatic 0.2.1 (Guille et al. 2025)Protocol: SEQC2 HCC1395 WES validation sample, somatic SNVs (Guille et al. 2025 Table S7)
Dataset: SEQC2 HCC1395/HCC1395BL WES, Fudan replicate (WES_FD_T_1), high-confidence regions
0.976 Precision (SNV only)
fraction · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

NeuSomatic on SEQC2 HCC1395 WES validation SNVs (Guille et al. 2025)

somatic-20261009-protocol-guille2025-seqc2-fd-wes-snv

Aggregation: Not reported

A benchmarking study of individual somatic variant callers and voting-based ensembles for whole-exome sequencing; Guille et al. 2025, Supplementary Table S7 (validation dataset) · Supplementary Table S7 (tables7_bbae697.xls, sheet 'Results'), I18; Tools 'NeuSomatic'; column 'PPV'
Configuration: NeuSomatic 0.2.1 (Guille et al. 2025)Protocol: SEQC2 HCC1395 WES validation sample, somatic SNVs (Guille et al. 2025 Table S7)
Dataset: SEQC2 HCC1395/HCC1395BL WES, Fudan replicate (WES_FD_T_1), high-confidence regions
0.729 Recall (SNV only)
fraction · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

NeuSomatic on SEQC2 HCC1395 WES validation SNVs (Guille et al. 2025)

somatic-20261009-protocol-guille2025-seqc2-fd-wes-snv

Aggregation: Not reported

A benchmarking study of individual somatic variant callers and voting-based ensembles for whole-exome sequencing; Guille et al. 2025, Supplementary Table S7 (validation dataset) · Supplementary Table S7 (tables7_bbae697.xls, sheet 'Results'), F18; Tools 'NeuSomatic'; column 'TPR'
Configuration: NeuSomatic 0.2.1 (Guille et al. 2025)Protocol: SEQC2 HCC1395 WES validation sample, somatic SNVs (Guille et al. 2025 Table S7)
Dataset: SEQC2 HCC1395/HCC1395BL WES, Fudan replicate (WES_FD_T_1), high-confidence regions
846 True positives (SNV only)
count · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

NeuSomatic on SEQC2 HCC1395 WES validation SNVs (Guille et al. 2025)

somatic-20261009-protocol-guille2025-seqc2-fd-wes-snv

Aggregation: Not reported

A benchmarking study of individual somatic variant callers and voting-based ensembles for whole-exome sequencing; Guille et al. 2025, Supplementary Table S7 (validation dataset) · Supplementary Table S7 (tables7_bbae697.xls, sheet 'Results'), D18; Tools 'NeuSomatic'; column 'TP'

Source checking is not independent reproduction. Release 2026-11-23-066f267ebcf4.

Use this configuration

How it works, versions and access

Additional methodological details, versions and access terms have not yet been extracted into a structured profile for this configuration. Consult the linked sources and evaluation records below.

Evidence

Source checking verifies the cited claim or transcription. It does not establish independent reproduction.

Evidence table

Inspect claims, sources and review details

Trace each statement to its source and review. A context-only reference supports the record generally; it does not verify an individual field. Source checking does not reproduce an experiment.

One row per statement and cited source. Multiple citations are not independent evaluations. Shared locators are labelled explicitly.

0 evidence rows matching the loaded filters

Claims, original sources and review scope · Release 2026-11-23-066f267ebcf4
Property and statementOriginal source and locationReview and provenance

No evidence rows match these filters. Choose another scope or clear the search.

Sources and history

Release 2026-11-23-066f267ebcf4 · Record review: source checked

3 source records and release historyDownload this release (gzip)
Technical metadata and record identifiers

Technical metadata for this record is tracked under stable ID somatic-20261009-config-guille2025-neusomatic.

Source locator: Table 1 row 'NeuSomatic'; Supplementary Table S7 row label 'NeuSomatic'; supplementary methods

Related records

How to cite

NeuSomatic 0.2.1 (Guille et al. 2025). Rewire biological model benchmark database, release 2026-11-23-066f267ebcf4. https://benchmarks.rewirebio.io/database/configuration/somatic-20261009-config-guille2025-neusomatic/

Release 2026-11-23-066f267ebcf4. Rankings and values change between releases, so keep the release id in the citation. Cite the original publication as well for any value you reuse: each result links its source.

The compilation and annotations made by Rewire in this release are offered under CC BY 4.0; values and text taken from cited sources stay under the terms of those sources and are not covered by this licence. Data licence

Suggest a correction