Overview
An explanatory profile has not yet been reviewed for this record.
Consult the linked sources for architecture or protocol details. Missing evidence is not evidence of a missing capability.
Model Capabilities & Hardware Requirements
Deployment facts recorded for TranceptEVE L. Fields the record does not carry are marked not recorded.
Evaluations and results
1 evaluation · 5 results. Different protocols are not a single leaderboard.
Dataset subset: ProteinGym substitution DMS assays (ProteinGym split)
Sorted by AUROC (higher is better). The best value in each column is highlighted. Decimals are rounded for display; each value links to the printed value and its source.
| Tested configuration | Protocol and dataset | AUROC | MCC | NDCG at 10% | Spearman | Top 10% recall |
|---|---|---|---|---|---|---|
| TranceptEVE LEvaluation | ProteinGym ZS-SUB-AUC: Zero-shot substitutions, AUC | 0.751 | Not reported | Not reported | Not reported | Not reported |
| TranceptEVE LEvaluation | ProteinGym ZS-SUB-MCC: Zero-shot substitutions, MCC | Not reported | 0.356 | Not reported | Not reported | Not reported |
| TranceptEVE LEvaluation | ProteinGym ZS-SUB-NDCG: Zero-shot substitutions, NDCG@10% | Not reported | Not reported | 0.786 | Not reported | Not reported |
| TranceptEVE LEvaluation | ProteinGym ZS-SUB-RECALL: Zero-shot substitutions, top 10% recall | Not reported | Not reported | Not reported | Not reported | 0.23 |
| TranceptEVE LEvaluation | ProteinGym ZS-SUB-SPEARMAN: Zero-shot substitutions, Spearman | Not reported | Not reported | Not reported | 0.456 | Not reported |
All 5 result rows with coverage, uncertainty and sources
Filter evaluations
Applied filters: All linked evaluations
| Tested configuration | Protocol and dataset | Finding | Evidence and details |
|---|---|---|---|
| Configuration: TranceptEVE L | Task: ProteinGym ZS-SUB-AUC: Zero-shot substitutions, AUC Dataset subset: ProteinGym substitution DMS assays (ProteinGym split) | 0.751 AUROC unitless · higher Uncertainty: Not yet extracted Coverage: Not reported scored / Not reported eligible | Author-reported evaluation · Source checkedMethods, coverage and sourceTranceptEVE L on ProteinGym ZS-SUB-AUC: Zero-shot substitutions, AUC Zero-shot scoring of substitution assays, averaged over assays with the correction the paper describes. Aggregation: Not reported ProteinGym: Large-Scale Benchmarks for Protein Fitness Prediction and Design · Table 2, row(TranceptEVE L), column(Zero-shot substitutions, AUC) |
| Configuration: TranceptEVE L | Task: ProteinGym ZS-SUB-MCC: Zero-shot substitutions, MCC Dataset subset: ProteinGym substitution DMS assays (ProteinGym split) | 0.356 MCC unitless · higher Uncertainty: Not yet extracted Coverage: Not reported scored / Not reported eligible | Author-reported evaluation · Source checkedMethods, coverage and sourceTranceptEVE L on ProteinGym ZS-SUB-MCC: Zero-shot substitutions, MCC Zero-shot scoring of substitution assays, averaged over assays with the correction the paper describes. Aggregation: Not reported ProteinGym: Large-Scale Benchmarks for Protein Fitness Prediction and Design · Table 2, row(TranceptEVE L), column(Zero-shot substitutions, MCC) |
| Configuration: TranceptEVE L | Task: ProteinGym ZS-SUB-NDCG: Zero-shot substitutions, NDCG@10% Dataset subset: ProteinGym substitution DMS assays (ProteinGym split) | 0.786 NDCG at 10% unitless · higher Uncertainty: Not yet extracted Coverage: Not reported scored / Not reported eligible | Author-reported evaluation · Source checkedMethods, coverage and sourceTranceptEVE L on ProteinGym ZS-SUB-NDCG: Zero-shot substitutions, NDCG@10% Zero-shot scoring of substitution assays, averaged over assays with the correction the paper describes. Aggregation: Not reported ProteinGym: Large-Scale Benchmarks for Protein Fitness Prediction and Design · Table 2, row(TranceptEVE L), column(Zero-shot substitutions, NDCG@10%) |
| Configuration: TranceptEVE L | Task: ProteinGym ZS-SUB-RECALL: Zero-shot substitutions, top 10% recall Dataset subset: ProteinGym substitution DMS assays (ProteinGym split) | 0.23 Top 10% recall fraction · higher Uncertainty: Not yet extracted Coverage: Not reported scored / Not reported eligible | Author-reported evaluation · Source checkedMethods, coverage and sourceTranceptEVE L on ProteinGym ZS-SUB-RECALL: Zero-shot substitutions, top 10% recall Zero-shot scoring of substitution assays, averaged over assays with the correction the paper describes. Aggregation: Not reported ProteinGym: Large-Scale Benchmarks for Protein Fitness Prediction and Design · Table 2, row(TranceptEVE L), column(Zero-shot substitutions, top 10% recall) |
| Configuration: TranceptEVE L | Task: ProteinGym ZS-SUB-SPEARMAN: Zero-shot substitutions, Spearman Dataset subset: ProteinGym substitution DMS assays (ProteinGym split) | 0.456 Spearman unitless · higher Uncertainty: Not yet extracted Coverage: Not reported scored / Not reported eligible | Author-reported evaluation · Source checkedMethods, coverage and sourceTranceptEVE L on ProteinGym ZS-SUB-SPEARMAN: Zero-shot substitutions, Spearman Zero-shot scoring of substitution assays, averaged over assays with the correction the paper describes. Aggregation: Not reported ProteinGym: Large-Scale Benchmarks for Protein Fitness Prediction and Design · Table 2, row(TranceptEVE L), column(Zero-shot substitutions, Spearman) |
Source checking is not independent reproduction. Release 2026-11-21-c8bea25e5abb.
Use this configuration
How it works, versions and access
Additional methodological details, versions and access terms have not yet been extracted into a structured profile for this configuration. Consult the linked sources and evaluation records below.
Evidence
Source checking verifies the cited claim or transcription. It does not establish independent reproduction.
Evidence table
Inspect claims, sources and review details
Trace each statement to its source and review. A context-only reference supports the record generally; it does not verify an individual field. Source checking does not reproduce an experiment.
One row per statement and cited source. Multiple citations are not independent evaluations. Shared locators are labelled explicitly.
0 evidence rows matching the loaded filters
| Property and statement | Original source and location | Review and provenance |
|---|
No evidence rows match these filters. Choose another scope or clear the search.
Sources and history
Release 2026-11-21-c8bea25e5abb · Record review: source checked
1 source record and release history
- ProteinGym: Large-Scale Benchmarks for Protein Fitness Prediction and Design · Original source · Primary full-text snapshot retrieved 2026-09-17; exact bytes pinned by SHA-256
Technical metadata and record identifiers
Technical metadata for this record is tracked under stable ID proteingym-method-trancepteve-l.
Source locator: Table 2, row(TranceptEVE L)
Related records
- system: TranceptEVE L on ProteinGym ZS-SUB-AUC: Zero-shot substitutions, AUC
- system: TranceptEVE L on ProteinGym ZS-SUB-MCC: Zero-shot substitutions, MCC
- system: TranceptEVE L on ProteinGym ZS-SUB-NDCG: Zero-shot substitutions, NDCG@10%
- system: TranceptEVE L on ProteinGym ZS-SUB-RECALL: Zero-shot substitutions, top 10% recall
- system: TranceptEVE L on ProteinGym ZS-SUB-SPEARMAN: Zero-shot substitutions, Spearman
How to cite
TranceptEVE L. Rewire biological model benchmark database, release 2026-11-21-c8bea25e5abb. https://benchmarks.rewirebio.io/database/configuration/proteingym-method-trancepteve-l/
Release 2026-11-21-c8bea25e5abb. Rankings and values change between releases, so keep the release id in the citation. Cite the original publication as well for any value you reuse: each result links its source.
The compilation and annotations made by Rewire in this release are offered under CC BY 4.0; values and text taken from cited sources stay under the terms of those sources and are not covered by this licence. Data licence