rewirebio.iobenchmarks
Configuration

ESM1b (Brandes et al. 2023 clinical benchmarks)

Configuration of ESM-1b: esm1b_t33_650M_UR50S; missense effect score is the log-likelihood ratio of the alternate versus reference amino acid; proteins longer than 1,022 aa tiled with 1,022 aa windows overlapping by at least 511 aa and combined by a weighted average.

92 evaluations · 184 results

Overview

An explanatory profile has not yet been reviewed for this record.

Consult the linked sources for architecture or protocol details. Missing evidence is not evidence of a missing capability.

Evaluations and results

92 evaluations · 184 results. Different protocols are not a single leaderboard.

Filter evaluations

Applied filters: All linked evaluations

Exact evaluated configurations and original reported results
Tested configurationProtocol and datasetFindingEvidence and details
Configuration: ESM1b (Brandes et al. 2023 clinical benchmarks)Protocol: ClinVar missense pathogenicity, variants scored by all 19 eligible methods (Brandes et al. 2023 Fig. 2e-f, Supplementary Table 2)
Dataset: ClinVar missense pathogenic vs benign, primary isoforms (Brandes et al. 2023, from the EVE portal)
0.884 AUPRC (balanced PRC-AUC: mean over 100 random downsamples to equal pathogenic and benign counts (80% of the minority class); zero-shot)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

ESM1b on ClinVar missense, variants scored by all 19 methods (Brandes et al. 2023)

gfm-guides-20261014-esm1b-protocol-clinvar-all-19-methods

Aggregation: Not reported

Brandes et al. 2023 Supplementary Table 2: full benchmark evaluations of ESM1b and all other methods · Supplementary Table 2 sheet 'Table_of_results_ClinVar' cell C2, row 'ESM1b', column 'AUC_Balanced_AUPRC'
Configuration: ESM1b (Brandes et al. 2023 clinical benchmarks)Protocol: ClinVar missense pathogenicity, variants scored by all 19 eligible methods (Brandes et al. 2023 Fig. 2e-f, Supplementary Table 2)
Dataset: ClinVar missense pathogenic vs benign, primary isoforms (Brandes et al. 2023, from the EVE portal)
0.892 AUROC (global ROC-AUC over all variants; zero-shot)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

ESM1b on ClinVar missense, variants scored by all 19 methods (Brandes et al. 2023)

gfm-guides-20261014-esm1b-protocol-clinvar-all-19-methods

Aggregation: Not reported

Brandes et al. 2023 Supplementary Table 2: full benchmark evaluations of ESM1b and all other methods · Supplementary Table 2 sheet 'Table_of_results_ClinVar' cell B2, row 'ESM1b', column 'AUC_AUROC'
Configuration: ESM1b (Brandes et al. 2023 clinical benchmarks)Protocol: ClinVar missense pathogenicity, ESM1b head to head with one other method on the variants both score (Brandes et al. 2023 Fig. 2g,h, Supplementary Table 2)
Dataset subset: ClinVar missense variants scored by both ESM1b and BayesDel (no AF) (Brandes et al. 2023)
0.906 AUPRC (balanced PRC-AUC over the variants both methods score: mean over 100 random downsamples to equal pathogenic and benign counts (80% of the minority class); zero-shot)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

ESM1b on ClinVar missense, head to head against BayesDel (no AF) (Brandes et al. 2023)

gfm-guides-20261014-esm1b-protocol-clinvar-head-to-head

Aggregation: Not reported

Brandes et al. 2023 Supplementary Table 2: full benchmark evaluations of ESM1b and all other methods · Supplementary Table 2 sheet 'Table_of_results_ClinVar' cell H21, row 'BayesDel (no AF)', column 'head2head_ESM1b_auc_Balanced_AUPRC'
Configuration: ESM1b (Brandes et al. 2023 clinical benchmarks)Protocol: ClinVar missense pathogenicity, ESM1b head to head with one other method on the variants both score (Brandes et al. 2023 Fig. 2g,h, Supplementary Table 2)
Dataset subset: ClinVar missense variants scored by both ESM1b and BayesDel (no AF) (Brandes et al. 2023)
0.906 AUROC (global ROC-AUC over the variants both methods score; zero-shot)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

ESM1b on ClinVar missense, head to head against BayesDel (no AF) (Brandes et al. 2023)

gfm-guides-20261014-esm1b-protocol-clinvar-head-to-head

Aggregation: Not reported

Brandes et al. 2023 Supplementary Table 2: full benchmark evaluations of ESM1b and all other methods · Supplementary Table 2 sheet 'Table_of_results_ClinVar' cell F21, row 'BayesDel (no AF)', column 'head2head_ESM1b_auc_AUROC'
Configuration: ESM1b (Brandes et al. 2023 clinical benchmarks)Protocol: ClinVar missense pathogenicity, ESM1b head to head with one other method on the variants both score (Brandes et al. 2023 Fig. 2g,h, Supplementary Table 2)
Dataset subset: ClinVar missense variants scored by both ESM1b and BayesDel (with AF) (Brandes et al. 2023)
0.906 AUPRC (balanced PRC-AUC over the variants both methods score: mean over 100 random downsamples to equal pathogenic and benign counts (80% of the minority class); zero-shot)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

ESM1b on ClinVar missense, head to head against BayesDel (with AF) (Brandes et al. 2023)

gfm-guides-20261014-esm1b-protocol-clinvar-head-to-head

Aggregation: Not reported

Brandes et al. 2023 Supplementary Table 2: full benchmark evaluations of ESM1b and all other methods · Supplementary Table 2 sheet 'Table_of_results_ClinVar' cell H22, row 'BayesDel (with AF)', column 'head2head_ESM1b_auc_Balanced_AUPRC'
Configuration: ESM1b (Brandes et al. 2023 clinical benchmarks)Protocol: ClinVar missense pathogenicity, ESM1b head to head with one other method on the variants both score (Brandes et al. 2023 Fig. 2g,h, Supplementary Table 2)
Dataset subset: ClinVar missense variants scored by both ESM1b and BayesDel (with AF) (Brandes et al. 2023)
0.906 AUROC (global ROC-AUC over the variants both methods score; zero-shot)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

ESM1b on ClinVar missense, head to head against BayesDel (with AF) (Brandes et al. 2023)

gfm-guides-20261014-esm1b-protocol-clinvar-head-to-head

Aggregation: Not reported

Brandes et al. 2023 Supplementary Table 2: full benchmark evaluations of ESM1b and all other methods · Supplementary Table 2 sheet 'Table_of_results_ClinVar' cell F22, row 'BayesDel (with AF)', column 'head2head_ESM1b_auc_AUROC'
Configuration: ESM1b (Brandes et al. 2023 clinical benchmarks)Protocol: ClinVar missense pathogenicity, ESM1b head to head with one other method on the variants both score (Brandes et al. 2023 Fig. 2g,h, Supplementary Table 2)
Dataset subset: ClinVar missense variants scored by both ESM1b and bStatistic (Brandes et al. 2023)
0.906 AUPRC (balanced PRC-AUC over the variants both methods score: mean over 100 random downsamples to equal pathogenic and benign counts (80% of the minority class); zero-shot)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

ESM1b on ClinVar missense, head to head against bStatistic (Brandes et al. 2023)

gfm-guides-20261014-esm1b-protocol-clinvar-head-to-head

Aggregation: Not reported

Brandes et al. 2023 Supplementary Table 2: full benchmark evaluations of ESM1b and all other methods · Supplementary Table 2 sheet 'Table_of_results_ClinVar' cell H19, row 'bStatistic', column 'head2head_ESM1b_auc_Balanced_AUPRC'
Configuration: ESM1b (Brandes et al. 2023 clinical benchmarks)Protocol: ClinVar missense pathogenicity, ESM1b head to head with one other method on the variants both score (Brandes et al. 2023 Fig. 2g,h, Supplementary Table 2)
Dataset subset: ClinVar missense variants scored by both ESM1b and bStatistic (Brandes et al. 2023)
0.905 AUROC (global ROC-AUC over the variants both methods score; zero-shot)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

ESM1b on ClinVar missense, head to head against bStatistic (Brandes et al. 2023)

gfm-guides-20261014-esm1b-protocol-clinvar-head-to-head

Aggregation: Not reported

Brandes et al. 2023 Supplementary Table 2: full benchmark evaluations of ESM1b and all other methods · Supplementary Table 2 sheet 'Table_of_results_ClinVar' cell F19, row 'bStatistic', column 'head2head_ESM1b_auc_AUROC'
Configuration: ESM1b (Brandes et al. 2023 clinical benchmarks)Protocol: ClinVar missense pathogenicity, ESM1b head to head with one other method on the variants both score (Brandes et al. 2023 Fig. 2g,h, Supplementary Table 2)
Dataset subset: ClinVar missense variants scored by both ESM1b and CADD (Brandes et al. 2023)
0.906 AUPRC (balanced PRC-AUC over the variants both methods score: mean over 100 random downsamples to equal pathogenic and benign counts (80% of the minority class); zero-shot)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

ESM1b on ClinVar missense, head to head against CADD (Brandes et al. 2023)

gfm-guides-20261014-esm1b-protocol-clinvar-head-to-head

Aggregation: Not reported

Brandes et al. 2023 Supplementary Table 2: full benchmark evaluations of ESM1b and all other methods · Supplementary Table 2 sheet 'Table_of_results_ClinVar' cell H23, row 'CADD', column 'head2head_ESM1b_auc_Balanced_AUPRC'
Configuration: ESM1b (Brandes et al. 2023 clinical benchmarks)Protocol: ClinVar missense pathogenicity, ESM1b head to head with one other method on the variants both score (Brandes et al. 2023 Fig. 2g,h, Supplementary Table 2)
Dataset subset: ClinVar missense variants scored by both ESM1b and CADD (Brandes et al. 2023)
0.906 AUROC (global ROC-AUC over the variants both methods score; zero-shot)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

ESM1b on ClinVar missense, head to head against CADD (Brandes et al. 2023)

gfm-guides-20261014-esm1b-protocol-clinvar-head-to-head

Aggregation: Not reported

Brandes et al. 2023 Supplementary Table 2: full benchmark evaluations of ESM1b and all other methods · Supplementary Table 2 sheet 'Table_of_results_ClinVar' cell F23, row 'CADD', column 'head2head_ESM1b_auc_AUROC'
Configuration: ESM1b (Brandes et al. 2023 clinical benchmarks)Protocol: ClinVar missense pathogenicity, ESM1b head to head with one other method on the variants both score (Brandes et al. 2023 Fig. 2g,h, Supplementary Table 2)
Dataset subset: ClinVar missense variants scored by both ESM1b and ClinPred (Brandes et al. 2023)
0.906 AUPRC (balanced PRC-AUC over the variants both methods score: mean over 100 random downsamples to equal pathogenic and benign counts (80% of the minority class); zero-shot)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

ESM1b on ClinVar missense, head to head against ClinPred (Brandes et al. 2023)

gfm-guides-20261014-esm1b-protocol-clinvar-head-to-head

Aggregation: Not reported

Brandes et al. 2023 Supplementary Table 2: full benchmark evaluations of ESM1b and all other methods · Supplementary Table 2 sheet 'Table_of_results_ClinVar' cell H24, row 'ClinPred', column 'head2head_ESM1b_auc_Balanced_AUPRC'
Configuration: ESM1b (Brandes et al. 2023 clinical benchmarks)Protocol: ClinVar missense pathogenicity, ESM1b head to head with one other method on the variants both score (Brandes et al. 2023 Fig. 2g,h, Supplementary Table 2)
Dataset subset: ClinVar missense variants scored by both ESM1b and ClinPred (Brandes et al. 2023)
0.906 AUROC (global ROC-AUC over the variants both methods score; zero-shot)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

ESM1b on ClinVar missense, head to head against ClinPred (Brandes et al. 2023)

gfm-guides-20261014-esm1b-protocol-clinvar-head-to-head

Aggregation: Not reported

Brandes et al. 2023 Supplementary Table 2: full benchmark evaluations of ESM1b and all other methods · Supplementary Table 2 sheet 'Table_of_results_ClinVar' cell F24, row 'ClinPred', column 'head2head_ESM1b_auc_AUROC'
Configuration: ESM1b (Brandes et al. 2023 clinical benchmarks)Protocol: ClinVar missense pathogenicity, ESM1b head to head with one other method on the variants both score (Brandes et al. 2023 Fig. 2g,h, Supplementary Table 2)
Dataset subset: ClinVar missense variants scored by both ESM1b and DANN (Brandes et al. 2023)
0.906 AUPRC (balanced PRC-AUC over the variants both methods score: mean over 100 random downsamples to equal pathogenic and benign counts (80% of the minority class); zero-shot)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

ESM1b on ClinVar missense, head to head against DANN (Brandes et al. 2023)

gfm-guides-20261014-esm1b-protocol-clinvar-head-to-head

Aggregation: Not reported

Brandes et al. 2023 Supplementary Table 2: full benchmark evaluations of ESM1b and all other methods · Supplementary Table 2 sheet 'Table_of_results_ClinVar' cell H25, row 'DANN', column 'head2head_ESM1b_auc_Balanced_AUPRC'
Configuration: ESM1b (Brandes et al. 2023 clinical benchmarks)Protocol: ClinVar missense pathogenicity, ESM1b head to head with one other method on the variants both score (Brandes et al. 2023 Fig. 2g,h, Supplementary Table 2)
Dataset subset: ClinVar missense variants scored by both ESM1b and DANN (Brandes et al. 2023)
0.906 AUROC (global ROC-AUC over the variants both methods score; zero-shot)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

ESM1b on ClinVar missense, head to head against DANN (Brandes et al. 2023)

gfm-guides-20261014-esm1b-protocol-clinvar-head-to-head

Aggregation: Not reported

Brandes et al. 2023 Supplementary Table 2: full benchmark evaluations of ESM1b and all other methods · Supplementary Table 2 sheet 'Table_of_results_ClinVar' cell F25, row 'DANN', column 'head2head_ESM1b_auc_AUROC'
Configuration: ESM1b (Brandes et al. 2023 clinical benchmarks)Protocol: ClinVar missense pathogenicity, ESM1b head to head with one other method on the variants both score (Brandes et al. 2023 Fig. 2g,h, Supplementary Table 2)
Dataset subset: ClinVar missense variants scored by both ESM1b and DEOGEN2 (Brandes et al. 2023)
0.906 AUPRC (balanced PRC-AUC over the variants both methods score: mean over 100 random downsamples to equal pathogenic and benign counts (80% of the minority class); zero-shot)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

ESM1b on ClinVar missense, head to head against DEOGEN2 (Brandes et al. 2023)

gfm-guides-20261014-esm1b-protocol-clinvar-head-to-head

Aggregation: Not reported

Brandes et al. 2023 Supplementary Table 2: full benchmark evaluations of ESM1b and all other methods · Supplementary Table 2 sheet 'Table_of_results_ClinVar' cell H26, row 'DEOGEN2', column 'head2head_ESM1b_auc_Balanced_AUPRC'
Configuration: ESM1b (Brandes et al. 2023 clinical benchmarks)Protocol: ClinVar missense pathogenicity, ESM1b head to head with one other method on the variants both score (Brandes et al. 2023 Fig. 2g,h, Supplementary Table 2)
Dataset subset: ClinVar missense variants scored by both ESM1b and DEOGEN2 (Brandes et al. 2023)
0.906 AUROC (global ROC-AUC over the variants both methods score; zero-shot)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

ESM1b on ClinVar missense, head to head against DEOGEN2 (Brandes et al. 2023)

gfm-guides-20261014-esm1b-protocol-clinvar-head-to-head

Aggregation: Not reported

Brandes et al. 2023 Supplementary Table 2: full benchmark evaluations of ESM1b and all other methods · Supplementary Table 2 sheet 'Table_of_results_ClinVar' cell F26, row 'DEOGEN2', column 'head2head_ESM1b_auc_AUROC'
Configuration: ESM1b (Brandes et al. 2023 clinical benchmarks)Protocol: ClinVar missense pathogenicity, ESM1b head to head with one other method on the variants both score (Brandes et al. 2023 Fig. 2g,h, Supplementary Table 2)
Dataset subset: ClinVar missense variants scored by both ESM1b and Eigen (Brandes et al. 2023)
0.907 AUPRC (balanced PRC-AUC over the variants both methods score: mean over 100 random downsamples to equal pathogenic and benign counts (80% of the minority class); zero-shot)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

ESM1b on ClinVar missense, head to head against Eigen (Brandes et al. 2023)

gfm-guides-20261014-esm1b-protocol-clinvar-head-to-head

Aggregation: Not reported

Brandes et al. 2023 Supplementary Table 2: full benchmark evaluations of ESM1b and all other methods · Supplementary Table 2 sheet 'Table_of_results_ClinVar' cell H27, row 'Eigen', column 'head2head_ESM1b_auc_Balanced_AUPRC'
Configuration: ESM1b (Brandes et al. 2023 clinical benchmarks)Protocol: ClinVar missense pathogenicity, ESM1b head to head with one other method on the variants both score (Brandes et al. 2023 Fig. 2g,h, Supplementary Table 2)
Dataset subset: ClinVar missense variants scored by both ESM1b and Eigen (Brandes et al. 2023)
0.906 AUROC (global ROC-AUC over the variants both methods score; zero-shot)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

ESM1b on ClinVar missense, head to head against Eigen (Brandes et al. 2023)

gfm-guides-20261014-esm1b-protocol-clinvar-head-to-head

Aggregation: Not reported

Brandes et al. 2023 Supplementary Table 2: full benchmark evaluations of ESM1b and all other methods · Supplementary Table 2 sheet 'Table_of_results_ClinVar' cell F27, row 'Eigen', column 'head2head_ESM1b_auc_AUROC'
Configuration: ESM1b (Brandes et al. 2023 clinical benchmarks)Protocol: ClinVar missense pathogenicity, ESM1b head to head with one other method on the variants both score (Brandes et al. 2023 Fig. 2g,h, Supplementary Table 2)
Dataset subset: ClinVar missense variants scored by both ESM1b and Eigen-PC (Brandes et al. 2023)
0.907 AUPRC (balanced PRC-AUC over the variants both methods score: mean over 100 random downsamples to equal pathogenic and benign counts (80% of the minority class); zero-shot)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

ESM1b on ClinVar missense, head to head against Eigen-PC (Brandes et al. 2023)

gfm-guides-20261014-esm1b-protocol-clinvar-head-to-head

Aggregation: Not reported

Brandes et al. 2023 Supplementary Table 2: full benchmark evaluations of ESM1b and all other methods · Supplementary Table 2 sheet 'Table_of_results_ClinVar' cell H28, row 'Eigen-PC', column 'head2head_ESM1b_auc_Balanced_AUPRC'
Configuration: ESM1b (Brandes et al. 2023 clinical benchmarks)Protocol: ClinVar missense pathogenicity, ESM1b head to head with one other method on the variants both score (Brandes et al. 2023 Fig. 2g,h, Supplementary Table 2)
Dataset subset: ClinVar missense variants scored by both ESM1b and Eigen-PC (Brandes et al. 2023)
0.906 AUROC (global ROC-AUC over the variants both methods score; zero-shot)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

ESM1b on ClinVar missense, head to head against Eigen-PC (Brandes et al. 2023)

gfm-guides-20261014-esm1b-protocol-clinvar-head-to-head

Aggregation: Not reported

Brandes et al. 2023 Supplementary Table 2: full benchmark evaluations of ESM1b and all other methods · Supplementary Table 2 sheet 'Table_of_results_ClinVar' cell F28, row 'Eigen-PC', column 'head2head_ESM1b_auc_AUROC'
Configuration: ESM1b (Brandes et al. 2023 clinical benchmarks)Protocol: ClinVar missense pathogenicity, ESM1b head to head with one other method on the variants both score (Brandes et al. 2023 Fig. 2g,h, Supplementary Table 2)
Dataset subset: ClinVar missense variants scored by both ESM1b and EVE (Brandes et al. 2023)
0.905 AUPRC (balanced PRC-AUC over the variants both methods score: mean over 100 random downsamples to equal pathogenic and benign counts (80% of the minority class); zero-shot)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

ESM1b on ClinVar missense, head to head against EVE (Brandes et al. 2023)

gfm-guides-20261014-esm1b-protocol-clinvar-head-to-head

Aggregation: Not reported

Brandes et al. 2023 Supplementary Table 2: full benchmark evaluations of ESM1b and all other methods · Supplementary Table 2 sheet 'Table_of_results_ClinVar' cell H3, row 'EVE', column 'head2head_ESM1b_auc_Balanced_AUPRC'
Configuration: ESM1b (Brandes et al. 2023 clinical benchmarks)Protocol: ClinVar missense pathogenicity, ESM1b head to head with one other method on the variants both score (Brandes et al. 2023 Fig. 2g,h, Supplementary Table 2)
Dataset subset: ClinVar missense variants scored by both ESM1b and EVE (Brandes et al. 2023)
0.906 AUROC (global ROC-AUC over the variants both methods score; zero-shot)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

ESM1b on ClinVar missense, head to head against EVE (Brandes et al. 2023)

gfm-guides-20261014-esm1b-protocol-clinvar-head-to-head

Aggregation: Not reported

Brandes et al. 2023 Supplementary Table 2: full benchmark evaluations of ESM1b and all other methods · Supplementary Table 2 sheet 'Table_of_results_ClinVar' cell F3, row 'EVE', column 'head2head_ESM1b_auc_AUROC'
Configuration: ESM1b (Brandes et al. 2023 clinical benchmarks)Protocol: ClinVar missense pathogenicity, ESM1b head to head with one other method on the variants both score (Brandes et al. 2023 Fig. 2g,h, Supplementary Table 2)
Dataset subset: ClinVar missense variants scored by both ESM1b and FATHMM (Brandes et al. 2023)
0.906 AUPRC (balanced PRC-AUC over the variants both methods score: mean over 100 random downsamples to equal pathogenic and benign counts (80% of the minority class); zero-shot)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

ESM1b on ClinVar missense, head to head against FATHMM (Brandes et al. 2023)

gfm-guides-20261014-esm1b-protocol-clinvar-head-to-head

Aggregation: Not reported

Brandes et al. 2023 Supplementary Table 2: full benchmark evaluations of ESM1b and all other methods · Supplementary Table 2 sheet 'Table_of_results_ClinVar' cell H29, row 'FATHMM', column 'head2head_ESM1b_auc_Balanced_AUPRC'
Configuration: ESM1b (Brandes et al. 2023 clinical benchmarks)Protocol: ClinVar missense pathogenicity, ESM1b head to head with one other method on the variants both score (Brandes et al. 2023 Fig. 2g,h, Supplementary Table 2)
Dataset subset: ClinVar missense variants scored by both ESM1b and FATHMM (Brandes et al. 2023)
0.906 AUROC (global ROC-AUC over the variants both methods score; zero-shot)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

ESM1b on ClinVar missense, head to head against FATHMM (Brandes et al. 2023)

gfm-guides-20261014-esm1b-protocol-clinvar-head-to-head

Aggregation: Not reported

Brandes et al. 2023 Supplementary Table 2: full benchmark evaluations of ESM1b and all other methods · Supplementary Table 2 sheet 'Table_of_results_ClinVar' cell F29, row 'FATHMM', column 'head2head_ESM1b_auc_AUROC'
Configuration: ESM1b (Brandes et al. 2023 clinical benchmarks)Protocol: ClinVar missense pathogenicity, ESM1b head to head with one other method on the variants both score (Brandes et al. 2023 Fig. 2g,h, Supplementary Table 2)
Dataset subset: ClinVar missense variants scored by both ESM1b and FATHMM-MKL (Brandes et al. 2023)
0.906 AUPRC (balanced PRC-AUC over the variants both methods score: mean over 100 random downsamples to equal pathogenic and benign counts (80% of the minority class); zero-shot)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

ESM1b on ClinVar missense, head to head against FATHMM-MKL (Brandes et al. 2023)

gfm-guides-20261014-esm1b-protocol-clinvar-head-to-head

Aggregation: Not reported

Brandes et al. 2023 Supplementary Table 2: full benchmark evaluations of ESM1b and all other methods · Supplementary Table 2 sheet 'Table_of_results_ClinVar' cell H30, row 'FATHMM-MKL', column 'head2head_ESM1b_auc_Balanced_AUPRC'

Source checking is not independent reproduction. Release 2026-10-22-1b7cf027e4f6.

Use this configuration

How it works, versions and access
Strengths, limitations and unresolved questions

Evidence

Source checking verifies the cited claim or transcription. It does not establish independent reproduction.

Evidence table

Inspect claims, sources and review details

Trace each statement to its source and review. A context-only reference supports the record generally; it does not verify an individual field. Source checking does not reproduce an experiment.

One row per statement and cited source. Multiple citations are not independent evaluations. Shared locators are labelled explicitly.

0 evidence rows matching the loaded filters

Claims, original sources and review scope · Release 2026-10-22-1b7cf027e4f6
Property and statementOriginal source and locationReview and provenance

No evidence rows match these filters. Choose another scope or clear the search.

Sources and history

Release 2026-10-22-1b7cf027e4f6 · Record review: source checked

2 source records and release historyDownload this release (gzip)
Technical metadata and extraction receipts

Stable ID: gfm-guides-20261014-esm1b-config-esm1b

areas
protein-function
contexts
clinical_research
method types
foundation_model
reported name
ESM1b
version
esm1b_t33_650M_UR50S
parameters
esm1b_t33_650M_UR50S; missense effect score is the log-likelihood ratio of the alternate versus reference amino acid; proteins longer than 1,022 aa tiled with 1,022 aa windows overlapping by at least 511 aa and combined by a weighted average
foundation model eligible
true
source locator
Supplementary Table 2 column vep_name 'ESM1b'; Methods 'ESM1b' and 'Other VEP methods'
provenance note
ESM1b as scored in the Brandes et al. 2023 clinical missense benchmarks.
Related records

Suggest a correction