rewirebio.iobenchmarks
Configuration

Concordant calls of Revel_b and PMut and rfPred (Cubuk et al. 2021)

Consensus of the component tool-threshold calls; discordant variants are treated as VUS and left out.

2 evaluations · 6 results

Overview

An explanatory profile has not yet been reviewed for this record.

Consult the linked sources for architecture or protocol details. Missing evidence is not evidence of a missing capability.

Model Capabilities & Hardware Requirements

Deployment facts recorded for Concordant calls of Revel_b and PMut and rfPred (Cubuk et al. 2021). Fields the record does not carry are marked not recorded.

ParametersNot recorded
Minimum VRAMNot recorded
Inference LatencyNot recorded
Context WindowNot recorded
AccessNot recorded
LicenseNot recorded

Evaluations and results

2 evaluations · 6 results. Different protocols are not a single leaderboard.

Sorted by Benignity likelihood ratio (Source 'negative likelihood ratio' (TNR/FNR): likelihood ratio for benignity of a tolerated call, BRCA1 functional truth set) (higher is better). The best value in each column is highlighted. Decimals are rounded for display; each value links to the printed value and its source.

Tested configurationProtocol and datasetBenignity likelihood ratio (Source 'negative likelihood ratio' (TNR/FNR): likelihood ratio for benignity of a tolerated call, BRCA1 functional truth set)Benignity likelihood ratio (Source 'negative likelihood ratio' (TNR/FNR): likelihood ratio for benignity of a tolerated call, BRCA2 functional truth set)False negatives (Functionally deleterious BRCA1 variants called tolerated)False negatives (Functionally deleterious BRCA2 variants called tolerated)Likelihood ratio (Positive likelihood ratio of a deleterious call (TPR/FPR), BRCA1 functional truth set)Likelihood ratio (Positive likelihood ratio of a deleterious call (TPR/FPR), BRCA2 functional truth set)
Concordant calls of Revel_b and PMut and rfPred (Cubuk et al. 2021)EvaluationBRCA1 functional truth set, binary in silico calls (Cubuk et al. 2021), BRCA1 functional truth set: 1641 missense variants classed deleterious or tolerated by HAP1 cell survival after saturation genome editing5.4Not reported51Not reported3.34Not reported
Concordant calls of Revel_b and PMut and rfPred (Cubuk et al. 2021)EvaluationBRCA2 functional truth set, binary in silico calls (Cubuk et al. 2021), BRCA2 functional truth set: 188 missense variants classed deleterious or tolerated by Homology-directed repairNot reported9.29Not reported5Not reported3.36
All 6 result rows with coverage, uncertainty and sources
Filter evaluations

Applied filters: All linked evaluations

Exact evaluated configurations and original reported results
Tested configurationProtocol and datasetFindingEvidence and details
Configuration: Concordant calls of Revel_b and PMut and rfPred (Cubuk et al. 2021)Protocol: BRCA1 functional truth set, binary in silico calls (Cubuk et al. 2021)
Dataset: BRCA1 functional truth set: 1641 missense variants classed deleterious or tolerated by HAP1 cell survival after saturation genome editing
5.4 Benignity likelihood ratio (Source 'negative likelihood ratio' (TNR/FNR): likelihood ratio for benignity of a tolerated call, BRCA1 functional truth set)
unitless · higher

Uncertainty: Sources conflict: Printed interval (4.87-5.98) has the same log-scale width as this row's positive likelihood ratio interval and is not consistent with the Supplementary Table 6 counts; kept in printed_source_cell only.

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

Combined-Revel_b-AND-PMut-AND-rfPred on the BRCA1 functional truth set (Cubuk et al. 2021)

brca-20261009-protocol-cubuk2021-brca1

Aggregation: Not reported

Clinical likelihood ratios and balanced accuracy for 44 in silico tools against multiple large-scale functional assays of cancer susceptibility genes; Cubuk et al. 2021, Supplementary tables 1-13 (41436_2021_1265_MOESM3_ESM.xlsx) · Supplementary Table 9 (sheet 'SupTable9_Likelihood_Ratios'), G80; tool 'Combined-Revel_b-AND-PMut-AND-rfPred'; column 'BRCA1_negative_LR'
Configuration: Concordant calls of Revel_b and PMut and rfPred (Cubuk et al. 2021)Protocol: BRCA1 functional truth set, binary in silico calls (Cubuk et al. 2021)
Dataset: BRCA1 functional truth set: 1641 missense variants classed deleterious or tolerated by HAP1 cell survival after saturation genome editing
51 False negatives (Functionally deleterious BRCA1 variants called tolerated)
count · lower

Uncertainty: Not applicable: Count

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

Combined-Revel_b-AND-PMut-AND-rfPred on the BRCA1 functional truth set (Cubuk et al. 2021)

brca-20261009-protocol-cubuk2021-brca1

Aggregation: Not reported

Clinical likelihood ratios and balanced accuracy for 44 in silico tools against multiple large-scale functional assays of cancer susceptibility genes; Cubuk et al. 2021, Supplementary tables 1-13 (41436_2021_1265_MOESM3_ESM.xlsx) · Supplementary Table 6 (sheet 'SupTable6_Tool_Counts'), L82; tool 'Combined-Revel_b-AND-PMut-AND-rfPred'; column 'BRCA1_FN'
Configuration: Concordant calls of Revel_b and PMut and rfPred (Cubuk et al. 2021)Protocol: BRCA1 functional truth set, binary in silico calls (Cubuk et al. 2021)
Dataset: BRCA1 functional truth set: 1641 missense variants classed deleterious or tolerated by HAP1 cell survival after saturation genome editing
3.34 Likelihood ratio (Positive likelihood ratio of a deleterious call (TPR/FPR), BRCA1 functional truth set)
unitless · higher

Uncertainty: CI 3.02 to 3.70. Interval level and method not printed.

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

Combined-Revel_b-AND-PMut-AND-rfPred on the BRCA1 functional truth set (Cubuk et al. 2021)

brca-20261009-protocol-cubuk2021-brca1

Aggregation: Not reported

Clinical likelihood ratios and balanced accuracy for 44 in silico tools against multiple large-scale functional assays of cancer susceptibility genes; Cubuk et al. 2021, Supplementary tables 1-13 (41436_2021_1265_MOESM3_ESM.xlsx) · Supplementary Table 9 (sheet 'SupTable9_Likelihood_Ratios'), F80; tool 'Combined-Revel_b-AND-PMut-AND-rfPred'; column 'BRCA1_positive_LR'
Configuration: Concordant calls of Revel_b and PMut and rfPred (Cubuk et al. 2021)Protocol: BRCA2 functional truth set, binary in silico calls (Cubuk et al. 2021)
Dataset: BRCA2 functional truth set: 188 missense variants classed deleterious or tolerated by Homology-directed repair
9.29 Benignity likelihood ratio (Source 'negative likelihood ratio' (TNR/FNR): likelihood ratio for benignity of a tolerated call, BRCA2 functional truth set)
unitless · higher

Uncertainty: Sources conflict: Printed interval (6.91-12.4) has the same log-scale width as this row's positive likelihood ratio interval and is not consistent with the Supplementary Table 6 counts; kept in printed_source_cell only.

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

Combined-Revel_b-AND-PMut-AND-rfPred on the BRCA2 functional truth set (Cubuk et al. 2021)

brca-20261009-protocol-cubuk2021-brca2

Aggregation: Not reported

Clinical likelihood ratios and balanced accuracy for 44 in silico tools against multiple large-scale functional assays of cancer susceptibility genes; Cubuk et al. 2021, Supplementary tables 1-13 (41436_2021_1265_MOESM3_ESM.xlsx) · Supplementary Table 9 (sheet 'SupTable9_Likelihood_Ratios'), I80; tool 'Combined-Revel_b-AND-PMut-AND-rfPred'; column 'BRCA2_negative_LR'
Configuration: Concordant calls of Revel_b and PMut and rfPred (Cubuk et al. 2021)Protocol: BRCA2 functional truth set, binary in silico calls (Cubuk et al. 2021)
Dataset: BRCA2 functional truth set: 188 missense variants classed deleterious or tolerated by Homology-directed repair
5 False negatives (Functionally deleterious BRCA2 variants called tolerated)
count · lower

Uncertainty: Not applicable: Count

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

Combined-Revel_b-AND-PMut-AND-rfPred on the BRCA2 functional truth set (Cubuk et al. 2021)

brca-20261009-protocol-cubuk2021-brca2

Aggregation: Not reported

Clinical likelihood ratios and balanced accuracy for 44 in silico tools against multiple large-scale functional assays of cancer susceptibility genes; Cubuk et al. 2021, Supplementary tables 1-13 (41436_2021_1265_MOESM3_ESM.xlsx) · Supplementary Table 6 (sheet 'SupTable6_Tool_Counts'), U82; tool 'Combined-Revel_b-AND-PMut-AND-rfPred'; column 'BRCA2_FN'
Configuration: Concordant calls of Revel_b and PMut and rfPred (Cubuk et al. 2021)Protocol: BRCA2 functional truth set, binary in silico calls (Cubuk et al. 2021)
Dataset: BRCA2 functional truth set: 188 missense variants classed deleterious or tolerated by Homology-directed repair
3.36 Likelihood ratio (Positive likelihood ratio of a deleterious call (TPR/FPR), BRCA2 functional truth set)
unitless · higher

Uncertainty: CI 2.50 to 4.51. Interval level and method not printed.

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

Combined-Revel_b-AND-PMut-AND-rfPred on the BRCA2 functional truth set (Cubuk et al. 2021)

brca-20261009-protocol-cubuk2021-brca2

Aggregation: Not reported

Clinical likelihood ratios and balanced accuracy for 44 in silico tools against multiple large-scale functional assays of cancer susceptibility genes; Cubuk et al. 2021, Supplementary tables 1-13 (41436_2021_1265_MOESM3_ESM.xlsx) · Supplementary Table 9 (sheet 'SupTable9_Likelihood_Ratios'), H80; tool 'Combined-Revel_b-AND-PMut-AND-rfPred'; column 'BRCA2_positive_LR'

Source checking is not independent reproduction. Release 2026-11-21-adc15377fab2.

Use this configuration

How it works, versions and access

Additional methodological details, versions and access terms have not yet been extracted into a structured profile for this configuration. Consult the linked sources and evaluation records below.

Evidence

Source checking verifies the cited claim or transcription. It does not establish independent reproduction.

Evidence table

Inspect claims, sources and review details

Trace each statement to its source and review. A context-only reference supports the record generally; it does not verify an individual field. Source checking does not reproduce an experiment.

One row per statement and cited source. Multiple citations are not independent evaluations. Shared locators are labelled explicitly.

0 evidence rows matching the loaded filters

Claims, original sources and review scope · Release 2026-11-21-adc15377fab2
Property and statementOriginal source and locationReview and provenance

No evidence rows match these filters. Choose another scope or clear the search.

Sources and history

Release 2026-11-21-adc15377fab2 · Record review: source checked

2 source records and release historyDownload this release (gzip)
Technical metadata and record identifiers

Technical metadata for this record is tracked under stable ID brca-20261009-config-cubuk2021-combined-revel-b-and-pmut-and-rfpred.

Source locator: Supplementary Table 5 row 82 ('Combined-Revel_b-AND-PMut-AND-rfPred')

Related records

How to cite

Concordant calls of Revel_b and PMut and rfPred (Cubuk et al. 2021). Rewire biological model benchmark database, release 2026-11-21-adc15377fab2. https://benchmarks.rewirebio.io/database/configuration/brca-20261009-config-cubuk2021-combined-revel-b-and-pmut-and-rfpred/

Release 2026-11-21-adc15377fab2. Rankings and values change between releases, so keep the release id in the citation. Cite the original publication as well for any value you reuse: each result links its source.

The compilation and annotations made by Rewire in this release are offered under CC BY 4.0; values and text taken from cited sources stay under the terms of those sources and are not covered by this licence. Data licence

Suggest a correction