rewirebio.iobenchmarks
Protocol

HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)

HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)

3 evaluations · 135 results

Overview

An explanatory profile has not yet been reviewed for this record.

Consult the linked sources for architecture or protocol details. Missing evidence is not evidence of a missing capability.

3 recorded evaluations, 135 metric rows. A comparison chart has not yet been validated for these results. The table retains the individual findings and their sources.

View coverage and remaining gaps across all benchmarks

Results

Results are available, but no reviewed comparison panel is linked in this release.

All evaluations

3 evaluations · 135 results. Different protocols are not a single leaderboard.

Filter evaluations

Applied filters: All linked evaluations

Exact evaluated configurations and original reported results
Tested configurationProtocol and datasetFindingEvidence and details
Configuration: Clair3, accuracy runs (Zheng et al. 2026 Supplementary Table 3)Protocol: HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)
Dataset: GIAB HG003 whole genome, PacBio Revio (2022Q4 release), subsampled to 10x-50x
91.4% F1 (Indel; GIAB v4.2.1 HG003 confident regions; PacBio 10x)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Clair3, HG003 PacBio small-variant accuracy (Zheng et al. 2026)

model-execution-20261011-protocol-zheng2026-hg003-accuracy-pacbio

Aggregation: Not reported

Accelerated long-read variant calling with Clair3 for whole-genome sequencing; Accelerated long-read variant calling with Clair3: Supplementary Data · Supplementary Table 3 (image, page 3), platform 'PacBio Revio', read coverage 10x, caller 'Clair3', column 'Indel F1-score'
Configuration: Clair3, accuracy runs (Zheng et al. 2026 Supplementary Table 3)Protocol: HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)
Dataset: GIAB HG003 whole genome, PacBio Revio (2022Q4 release), subsampled to 10x-50x
94.2% Precision (Indel; GIAB v4.2.1 HG003 confident regions; PacBio 10x)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Clair3, HG003 PacBio small-variant accuracy (Zheng et al. 2026)

model-execution-20261011-protocol-zheng2026-hg003-accuracy-pacbio

Aggregation: Not reported

Accelerated long-read variant calling with Clair3 for whole-genome sequencing; Accelerated long-read variant calling with Clair3: Supplementary Data · Supplementary Table 3 (image, page 3), platform 'PacBio Revio', read coverage 10x, caller 'Clair3', column 'Indel Precision'
Configuration: Clair3, accuracy runs (Zheng et al. 2026 Supplementary Table 3)Protocol: HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)
Dataset: GIAB HG003 whole genome, PacBio Revio (2022Q4 release), subsampled to 10x-50x
88.7% Recall (Indel; GIAB v4.2.1 HG003 confident regions; PacBio 10x)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Clair3, HG003 PacBio small-variant accuracy (Zheng et al. 2026)

model-execution-20261011-protocol-zheng2026-hg003-accuracy-pacbio

Aggregation: Not reported

Accelerated long-read variant calling with Clair3 for whole-genome sequencing; Accelerated long-read variant calling with Clair3: Supplementary Data · Supplementary Table 3 (image, page 3), platform 'PacBio Revio', read coverage 10x, caller 'Clair3', column 'Indel Recall'
Configuration: Clair3, accuracy runs (Zheng et al. 2026 Supplementary Table 3)Protocol: HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)
Dataset: GIAB HG003 whole genome, PacBio Revio (2022Q4 release), subsampled to 10x-50x
97.6% F1 (SNPs and indels; GIAB v4.2.1 HG003 confident regions; PacBio 10x)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Clair3, HG003 PacBio small-variant accuracy (Zheng et al. 2026)

model-execution-20261011-protocol-zheng2026-hg003-accuracy-pacbio

Aggregation: Not reported

Accelerated long-read variant calling with Clair3 for whole-genome sequencing; Accelerated long-read variant calling with Clair3: Supplementary Data · Supplementary Table 3 (image, page 3), platform 'PacBio Revio', read coverage 10x, caller 'Clair3', column 'Overall F1-score'
Configuration: Clair3, accuracy runs (Zheng et al. 2026 Supplementary Table 3)Protocol: HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)
Dataset: GIAB HG003 whole genome, PacBio Revio (2022Q4 release), subsampled to 10x-50x
98.6% Precision (SNPs and indels; GIAB v4.2.1 HG003 confident regions; PacBio 10x)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Clair3, HG003 PacBio small-variant accuracy (Zheng et al. 2026)

model-execution-20261011-protocol-zheng2026-hg003-accuracy-pacbio

Aggregation: Not reported

Accelerated long-read variant calling with Clair3 for whole-genome sequencing; Accelerated long-read variant calling with Clair3: Supplementary Data · Supplementary Table 3 (image, page 3), platform 'PacBio Revio', read coverage 10x, caller 'Clair3', column 'Overall Precision'
Configuration: Clair3, accuracy runs (Zheng et al. 2026 Supplementary Table 3)Protocol: HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)
Dataset: GIAB HG003 whole genome, PacBio Revio (2022Q4 release), subsampled to 10x-50x
96.7% Recall (SNPs and indels; GIAB v4.2.1 HG003 confident regions; PacBio 10x)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Clair3, HG003 PacBio small-variant accuracy (Zheng et al. 2026)

model-execution-20261011-protocol-zheng2026-hg003-accuracy-pacbio

Aggregation: Not reported

Accelerated long-read variant calling with Clair3 for whole-genome sequencing; Accelerated long-read variant calling with Clair3: Supplementary Data · Supplementary Table 3 (image, page 3), platform 'PacBio Revio', read coverage 10x, caller 'Clair3', column 'Overall Recall'
Configuration: Clair3, accuracy runs (Zheng et al. 2026 Supplementary Table 3)Protocol: HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)
Dataset: GIAB HG003 whole genome, PacBio Revio (2022Q4 release), subsampled to 10x-50x
98.5% F1 (SNP; GIAB v4.2.1 HG003 confident regions; PacBio 10x)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Clair3, HG003 PacBio small-variant accuracy (Zheng et al. 2026)

model-execution-20261011-protocol-zheng2026-hg003-accuracy-pacbio

Aggregation: Not reported

Accelerated long-read variant calling with Clair3 for whole-genome sequencing; Accelerated long-read variant calling with Clair3: Supplementary Data · Supplementary Table 3 (image, page 3), platform 'PacBio Revio', read coverage 10x, caller 'Clair3', column 'SNP F1-score'
Configuration: Clair3, accuracy runs (Zheng et al. 2026 Supplementary Table 3)Protocol: HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)
Dataset: GIAB HG003 whole genome, PacBio Revio (2022Q4 release), subsampled to 10x-50x
99.2% Precision (SNP; GIAB v4.2.1 HG003 confident regions; PacBio 10x)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Clair3, HG003 PacBio small-variant accuracy (Zheng et al. 2026)

model-execution-20261011-protocol-zheng2026-hg003-accuracy-pacbio

Aggregation: Not reported

Accelerated long-read variant calling with Clair3 for whole-genome sequencing; Accelerated long-read variant calling with Clair3: Supplementary Data · Supplementary Table 3 (image, page 3), platform 'PacBio Revio', read coverage 10x, caller 'Clair3', column 'SNP Precision'
Configuration: Clair3, accuracy runs (Zheng et al. 2026 Supplementary Table 3)Protocol: HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)
Dataset: GIAB HG003 whole genome, PacBio Revio (2022Q4 release), subsampled to 10x-50x
97.9% Recall (SNP; GIAB v4.2.1 HG003 confident regions; PacBio 10x)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Clair3, HG003 PacBio small-variant accuracy (Zheng et al. 2026)

model-execution-20261011-protocol-zheng2026-hg003-accuracy-pacbio

Aggregation: Not reported

Accelerated long-read variant calling with Clair3 for whole-genome sequencing; Accelerated long-read variant calling with Clair3: Supplementary Data · Supplementary Table 3 (image, page 3), platform 'PacBio Revio', read coverage 10x, caller 'Clair3', column 'SNP Recall'
Configuration: Clair3, accuracy runs (Zheng et al. 2026 Supplementary Table 3)Protocol: HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)
Dataset: GIAB HG003 whole genome, PacBio Revio (2022Q4 release), subsampled to 10x-50x
97.7% F1 (Indel; GIAB v4.2.1 HG003 confident regions; PacBio 20x)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Clair3, HG003 PacBio small-variant accuracy (Zheng et al. 2026)

model-execution-20261011-protocol-zheng2026-hg003-accuracy-pacbio

Aggregation: Not reported

Accelerated long-read variant calling with Clair3 for whole-genome sequencing; Accelerated long-read variant calling with Clair3: Supplementary Data · Supplementary Table 3 (image, page 3), platform 'PacBio Revio', read coverage 20x, caller 'Clair3', column 'Indel F1-score'
Configuration: Clair3, accuracy runs (Zheng et al. 2026 Supplementary Table 3)Protocol: HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)
Dataset: GIAB HG003 whole genome, PacBio Revio (2022Q4 release), subsampled to 10x-50x
98.1% Precision (Indel; GIAB v4.2.1 HG003 confident regions; PacBio 20x)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Clair3, HG003 PacBio small-variant accuracy (Zheng et al. 2026)

model-execution-20261011-protocol-zheng2026-hg003-accuracy-pacbio

Aggregation: Not reported

Accelerated long-read variant calling with Clair3 for whole-genome sequencing; Accelerated long-read variant calling with Clair3: Supplementary Data · Supplementary Table 3 (image, page 3), platform 'PacBio Revio', read coverage 20x, caller 'Clair3', column 'Indel Precision'
Configuration: Clair3, accuracy runs (Zheng et al. 2026 Supplementary Table 3)Protocol: HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)
Dataset: GIAB HG003 whole genome, PacBio Revio (2022Q4 release), subsampled to 10x-50x
97.3% Recall (Indel; GIAB v4.2.1 HG003 confident regions; PacBio 20x)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Clair3, HG003 PacBio small-variant accuracy (Zheng et al. 2026)

model-execution-20261011-protocol-zheng2026-hg003-accuracy-pacbio

Aggregation: Not reported

Accelerated long-read variant calling with Clair3 for whole-genome sequencing; Accelerated long-read variant calling with Clair3: Supplementary Data · Supplementary Table 3 (image, page 3), platform 'PacBio Revio', read coverage 20x, caller 'Clair3', column 'Indel Recall'
Configuration: Clair3, accuracy runs (Zheng et al. 2026 Supplementary Table 3)Protocol: HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)
Dataset: GIAB HG003 whole genome, PacBio Revio (2022Q4 release), subsampled to 10x-50x
99.4% F1 (SNPs and indels; GIAB v4.2.1 HG003 confident regions; PacBio 20x)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Clair3, HG003 PacBio small-variant accuracy (Zheng et al. 2026)

model-execution-20261011-protocol-zheng2026-hg003-accuracy-pacbio

Aggregation: Not reported

Accelerated long-read variant calling with Clair3 for whole-genome sequencing; Accelerated long-read variant calling with Clair3: Supplementary Data · Supplementary Table 3 (image, page 3), platform 'PacBio Revio', read coverage 20x, caller 'Clair3', column 'Overall F1-score'
Configuration: Clair3, accuracy runs (Zheng et al. 2026 Supplementary Table 3)Protocol: HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)
Dataset: GIAB HG003 whole genome, PacBio Revio (2022Q4 release), subsampled to 10x-50x
99.6% Precision (SNPs and indels; GIAB v4.2.1 HG003 confident regions; PacBio 20x)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Clair3, HG003 PacBio small-variant accuracy (Zheng et al. 2026)

model-execution-20261011-protocol-zheng2026-hg003-accuracy-pacbio

Aggregation: Not reported

Accelerated long-read variant calling with Clair3 for whole-genome sequencing; Accelerated long-read variant calling with Clair3: Supplementary Data · Supplementary Table 3 (image, page 3), platform 'PacBio Revio', read coverage 20x, caller 'Clair3', column 'Overall Precision'
Configuration: Clair3, accuracy runs (Zheng et al. 2026 Supplementary Table 3)Protocol: HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)
Dataset: GIAB HG003 whole genome, PacBio Revio (2022Q4 release), subsampled to 10x-50x
99.3% Recall (SNPs and indels; GIAB v4.2.1 HG003 confident regions; PacBio 20x)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Clair3, HG003 PacBio small-variant accuracy (Zheng et al. 2026)

model-execution-20261011-protocol-zheng2026-hg003-accuracy-pacbio

Aggregation: Not reported

Accelerated long-read variant calling with Clair3 for whole-genome sequencing; Accelerated long-read variant calling with Clair3: Supplementary Data · Supplementary Table 3 (image, page 3), platform 'PacBio Revio', read coverage 20x, caller 'Clair3', column 'Overall Recall'
Configuration: Clair3, accuracy runs (Zheng et al. 2026 Supplementary Table 3)Protocol: HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)
Dataset: GIAB HG003 whole genome, PacBio Revio (2022Q4 release), subsampled to 10x-50x
99.7% F1 (SNP; GIAB v4.2.1 HG003 confident regions; PacBio 20x)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Clair3, HG003 PacBio small-variant accuracy (Zheng et al. 2026)

model-execution-20261011-protocol-zheng2026-hg003-accuracy-pacbio

Aggregation: Not reported

Accelerated long-read variant calling with Clair3 for whole-genome sequencing; Accelerated long-read variant calling with Clair3: Supplementary Data · Supplementary Table 3 (image, page 3), platform 'PacBio Revio', read coverage 20x, caller 'Clair3', column 'SNP F1-score'
Configuration: Clair3, accuracy runs (Zheng et al. 2026 Supplementary Table 3)Protocol: HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)
Dataset: GIAB HG003 whole genome, PacBio Revio (2022Q4 release), subsampled to 10x-50x
99.8% Precision (SNP; GIAB v4.2.1 HG003 confident regions; PacBio 20x)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Clair3, HG003 PacBio small-variant accuracy (Zheng et al. 2026)

model-execution-20261011-protocol-zheng2026-hg003-accuracy-pacbio

Aggregation: Not reported

Accelerated long-read variant calling with Clair3 for whole-genome sequencing; Accelerated long-read variant calling with Clair3: Supplementary Data · Supplementary Table 3 (image, page 3), platform 'PacBio Revio', read coverage 20x, caller 'Clair3', column 'SNP Precision'
Configuration: Clair3, accuracy runs (Zheng et al. 2026 Supplementary Table 3)Protocol: HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)
Dataset: GIAB HG003 whole genome, PacBio Revio (2022Q4 release), subsampled to 10x-50x
99.6% Recall (SNP; GIAB v4.2.1 HG003 confident regions; PacBio 20x)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Clair3, HG003 PacBio small-variant accuracy (Zheng et al. 2026)

model-execution-20261011-protocol-zheng2026-hg003-accuracy-pacbio

Aggregation: Not reported

Accelerated long-read variant calling with Clair3 for whole-genome sequencing; Accelerated long-read variant calling with Clair3: Supplementary Data · Supplementary Table 3 (image, page 3), platform 'PacBio Revio', read coverage 20x, caller 'Clair3', column 'SNP Recall'
Configuration: Clair3, accuracy runs (Zheng et al. 2026 Supplementary Table 3)Protocol: HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)
Dataset: GIAB HG003 whole genome, PacBio Revio (2022Q4 release), subsampled to 10x-50x
99% F1 (Indel; GIAB v4.2.1 HG003 confident regions; PacBio 30x)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Clair3, HG003 PacBio small-variant accuracy (Zheng et al. 2026)

model-execution-20261011-protocol-zheng2026-hg003-accuracy-pacbio

Aggregation: Not reported

Accelerated long-read variant calling with Clair3 for whole-genome sequencing; Accelerated long-read variant calling with Clair3: Supplementary Data · Supplementary Table 3 (image, page 3), platform 'PacBio Revio', read coverage 30x, caller 'Clair3', column 'Indel F1-score'
Configuration: Clair3, accuracy runs (Zheng et al. 2026 Supplementary Table 3)Protocol: HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)
Dataset: GIAB HG003 whole genome, PacBio Revio (2022Q4 release), subsampled to 10x-50x
99% Precision (Indel; GIAB v4.2.1 HG003 confident regions; PacBio 30x)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Clair3, HG003 PacBio small-variant accuracy (Zheng et al. 2026)

model-execution-20261011-protocol-zheng2026-hg003-accuracy-pacbio

Aggregation: Not reported

Accelerated long-read variant calling with Clair3 for whole-genome sequencing; Accelerated long-read variant calling with Clair3: Supplementary Data · Supplementary Table 3 (image, page 3), platform 'PacBio Revio', read coverage 30x, caller 'Clair3', column 'Indel Precision'
Configuration: Clair3, accuracy runs (Zheng et al. 2026 Supplementary Table 3)Protocol: HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)
Dataset: GIAB HG003 whole genome, PacBio Revio (2022Q4 release), subsampled to 10x-50x
98.9% Recall (Indel; GIAB v4.2.1 HG003 confident regions; PacBio 30x)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Clair3, HG003 PacBio small-variant accuracy (Zheng et al. 2026)

model-execution-20261011-protocol-zheng2026-hg003-accuracy-pacbio

Aggregation: Not reported

Accelerated long-read variant calling with Clair3 for whole-genome sequencing; Accelerated long-read variant calling with Clair3: Supplementary Data · Supplementary Table 3 (image, page 3), platform 'PacBio Revio', read coverage 30x, caller 'Clair3', column 'Indel Recall'
Configuration: Clair3, accuracy runs (Zheng et al. 2026 Supplementary Table 3)Protocol: HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)
Dataset: GIAB HG003 whole genome, PacBio Revio (2022Q4 release), subsampled to 10x-50x
99.7% F1 (SNPs and indels; GIAB v4.2.1 HG003 confident regions; PacBio 30x)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Clair3, HG003 PacBio small-variant accuracy (Zheng et al. 2026)

model-execution-20261011-protocol-zheng2026-hg003-accuracy-pacbio

Aggregation: Not reported

Accelerated long-read variant calling with Clair3 for whole-genome sequencing; Accelerated long-read variant calling with Clair3: Supplementary Data · Supplementary Table 3 (image, page 3), platform 'PacBio Revio', read coverage 30x, caller 'Clair3', column 'Overall F1-score'
Configuration: Clair3, accuracy runs (Zheng et al. 2026 Supplementary Table 3)Protocol: HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)
Dataset: GIAB HG003 whole genome, PacBio Revio (2022Q4 release), subsampled to 10x-50x
99.8% Precision (SNPs and indels; GIAB v4.2.1 HG003 confident regions; PacBio 30x)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Clair3, HG003 PacBio small-variant accuracy (Zheng et al. 2026)

model-execution-20261011-protocol-zheng2026-hg003-accuracy-pacbio

Aggregation: Not reported

Accelerated long-read variant calling with Clair3 for whole-genome sequencing; Accelerated long-read variant calling with Clair3: Supplementary Data · Supplementary Table 3 (image, page 3), platform 'PacBio Revio', read coverage 30x, caller 'Clair3', column 'Overall Precision'
Configuration: Clair3, accuracy runs (Zheng et al. 2026 Supplementary Table 3)Protocol: HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)
Dataset: GIAB HG003 whole genome, PacBio Revio (2022Q4 release), subsampled to 10x-50x
99.7% Recall (SNPs and indels; GIAB v4.2.1 HG003 confident regions; PacBio 30x)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Clair3, HG003 PacBio small-variant accuracy (Zheng et al. 2026)

model-execution-20261011-protocol-zheng2026-hg003-accuracy-pacbio

Aggregation: Not reported

Accelerated long-read variant calling with Clair3 for whole-genome sequencing; Accelerated long-read variant calling with Clair3: Supplementary Data · Supplementary Table 3 (image, page 3), platform 'PacBio Revio', read coverage 30x, caller 'Clair3', column 'Overall Recall'
Configuration: Clair3, accuracy runs (Zheng et al. 2026 Supplementary Table 3)Protocol: HG003 PacBio Revio WGS small-variant accuracy against GIAB v4.2.1, Clair3 versus DeepVariant (Zheng et al. 2026 Supplementary Table 3)
Dataset: GIAB HG003 whole genome, PacBio Revio (2022Q4 release), subsampled to 10x-50x
99.8% F1 (SNP; GIAB v4.2.1 HG003 confident regions; PacBio 30x)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

Clair3, HG003 PacBio small-variant accuracy (Zheng et al. 2026)

model-execution-20261011-protocol-zheng2026-hg003-accuracy-pacbio

Aggregation: Not reported

Accelerated long-read variant calling with Clair3 for whole-genome sequencing; Accelerated long-read variant calling with Clair3: Supplementary Data · Supplementary Table 3 (image, page 3), platform 'PacBio Revio', read coverage 30x, caller 'Clair3', column 'SNP F1-score'

Source checking is not independent reproduction. Release 2026-10-22-1b7cf027e4f6.

Methods and evaluation design

Procedure, tasks and evaluated configurations

Recorded evaluations

Each evaluation records what was tested and under which conditions.

Baseline coverage

Reference methods help show what a model adds beyond simple controls. We track a null control and a conventional method for each protocol.

0 of 2 active baseline roles have published Rewire measurements in this release. Measurements on a selected protocol do not establish coverage of an entire suite.

No execution recipe linked to this protocol. Recipe availability does not establish a completed evaluation.

Author-reported evaluations
2
External evaluations
1

Literature evidence is not a Rewire measurement. Executed but unpublished runs and private review status are not included.

Null control

Proposed control: requires review

Select a task-valid null control after reviewing inputs and metric

Protocol-specific applicability, permitted inputs, access, split, evaluator and execution requirements need review before implementation or execution.

This is a suggested selection rule, not a validated method or a measured score.

Conventional reference

Proposed control: requires review

Select an upstream conventional reference after reviewing the full protocol

Protocol-specific applicability, permitted inputs, access, split, evaluator and execution requirements need review before implementation or execution.

This is a suggested selection rule, not a validated method or a measured score.

Protocol coverage CSV (gzip) · Model evaluation matrix (gzip) · Source table (gzip) · Release and checksums (gzip)

Coverage is derived from release 2026-10-22-1b7cf027e4f6. Source citations describe the original records; they do not validate an unreviewed baseline proposal. No results have been generated by this audit.

Run instructions

No runnable recipe has been reviewed for this protocol. Dataset access, model requirements, licences and compute requirements must be checked against its sources before execution.

Strengths, limitations and unresolved questions

Evidence

Source checking verifies the cited claim or transcription. It does not establish independent reproduction.

Evidence table

Inspect claims, sources and review details

Trace each statement to its source and review. A context-only reference supports the record generally; it does not verify an individual field. Source checking does not reproduce an experiment.

One row per statement and cited source. Multiple citations are not independent evaluations. Shared locators are labelled explicitly.

0 evidence rows matching the loaded filters

Claims, original sources and review scope · Release 2026-10-22-1b7cf027e4f6
Property and statementOriginal source and locationReview and provenance

No evidence rows match these filters. Choose another scope or clear the search.

Sources and history

Release 2026-10-22-1b7cf027e4f6 · Record review: source checked

2 source records and release historyDownload this release (gzip)
Technical metadata and extraction receipts

Stable ID: model-execution-20261011-protocol-zheng2026-hg003-accuracy-pacbio

areas
dna-genomes
contexts
research
protocol
VCF from each caller compared with GIAB v4.2.1 HG003 truth in the confident regions using hap.py 0.3.12 with the vcfeval engine, PASS calls only; precision, recall and F1 overall, for SNPs and for indels.
version
Supplementary Table 3
metric
f1-score
limitations
One value per configuration and coverage is printed; the number of runs behind it is not stated and no spread is printed.; Author-reported: the authors develop Clair3; DeepVariant was run by them.; Results 3.2 quote PacBio 10x values (Clair3 SNP F1 98.54%, indel 91.39%; DeepVariant 97.81% and 90.74%); the DeepVariant 10x values differ slightly from Supplementary Table 3 (97.80% and 91.08%).; No runtime is printed in this table.; The source has an unresolved evidence concern (Supplementary Tables 2 and 3 conflict with the Results text); see the source record.
source locator
Supplementary Table 3; Supplementary Notes; Results 3.1-3.2
Related records

Suggest a correction