ProteinGym zero-shot paired difference from HyPLM-Flash (HyPLM report)
Measure HyPLM-Flash's ProteinGym Spearman correlation minus a baseline's, with a paired bootstrap interval over assays.
Overview
An explanatory profile has not yet been reviewed for this record.
Consult the linked sources for architecture or protocol details. Missing evidence is not evidence of a missing capability.
4 recorded evaluations, 4 metric rows. A comparison chart has not yet been validated for these results. The table retains the individual findings and their sources.
Results
Results are available, but no reviewed comparison panel is linked in this release.
All evaluations
4 evaluations · 4 results. Different protocols are not a single leaderboard.
Protocol: ProteinGym zero-shot paired difference from HyPLM-Flash (HyPLM report) · Dataset subset: ProteinGym DMS substitution assays at commit 144fe22 (217 assays)
Sorted by Spearman correlation difference (HyPLM-Flash minus the baseline, Spearman correlation over the 217 ProteinGym v1.3 substitution assays with the official aggregation; 95% interval from 5,000 bootstrap replicates over assays, recomputing the official aggregation each time, with identical resamples for both models; the reference system is HyPLM-Flash) (higher is better). The best value in each column is highlighted. Decimals are rounded for display; each value links to the printed value and its source.
| Tested configuration | Spearman correlation difference (HyPLM-Flash minus the baseline, Spearman correlation over the 217 ProteinGym v1.3 substitution assays with the official aggregation; 95% interval from 5,000 bootstrap replicates over assays, recomputing the official aggregation each time, with identical resamples for both models; the reference system is HyPLM-Flash) |
|---|---|
| ESM C 600M (HyPLM report)Evaluation | 0.003 (best in column) |
| DPLM-650M (HyPLM report)Evaluation | −0.001 |
| ESM-2 650M (HyPLM report)Evaluation | −0.006 |
| E1-600M (HyPLM report)Evaluation | −0.011 |
All 4 result rows with coverage, uncertainty and sources
Filter evaluations
Applied filters: All linked evaluations
Source checking is not independent reproduction. Release 2026-11-21-adc15377fab2.
Methods and evaluation design
Procedure, tasks and evaluated configurations
Recorded evaluations
Each evaluation records what was tested and under which conditions.
Baseline coverage
Reference methods help show what a model adds beyond simple controls. We track a null control and a conventional method for each protocol.
0 of 2 active baseline roles have published Rewire measurements in this release. Measurements on a selected protocol do not establish coverage of an entire suite.
No execution recipe linked to this protocol. Recipe availability does not establish a completed evaluation.
- Author-reported evaluations
- 4
Literature evidence is not a Rewire measurement. Executed but unpublished runs and private review status are not included.
Null control
Proposed control: requires review
Protocol-valid seeded random ranking; no fitting on assay labels
Protocol-specific applicability, permitted inputs, access, split, evaluator and execution requirements need review before implementation or execution.
This is a suggested selection rule, not a validated method or a measured score.
Conventional reference
Proposed control: requires review
Established label-free reference with explicitly permitted sequence/MSA inputs
Protocol-specific applicability, permitted inputs, access, split, evaluator and execution requirements need review before implementation or execution.
This is a suggested selection rule, not a validated method or a measured score.
Protocol coverage CSV (gzip) · Model evaluation matrix (gzip) · Source table (gzip) · Release and checksums (gzip)
Coverage is derived from release 2026-11-21-adc15377fab2. Source citations describe the original records; they do not validate an unreviewed baseline proposal. No results have been generated by this audit.
Run instructions
No runnable recipe has been reviewed for this protocol. Dataset access, model requirements, licences and compute requirements must be checked against its sources before execution.
Evidence
Source checking verifies the cited claim or transcription. It does not establish independent reproduction.
Evidence table
Inspect claims, sources and review details
Trace each statement to its source and review. A context-only reference supports the record generally; it does not verify an individual field. Source checking does not reproduce an experiment.
One row per statement and cited source. Multiple citations are not independent evaluations. Shared locators are labelled explicitly.
0 evidence rows matching the loaded filters
| Property and statement | Original source and location | Review and provenance |
|---|
No evidence rows match these filters. Choose another scope or clear the search.
Sources and history
Release 2026-11-21-adc15377fab2 · Record review: source checked
1 source record and release history
- HyPLM Technical Report (Hyra Team, 2026-10-12) · Original source · Dated 2026-10-12 on page 1; retrieved at commit 0dcc533cc9f8f76c90ecbfe944df816b6672328a (13 pages)
Technical metadata and record identifiers
Technical metadata for this record is tracked under stable ID hyplm-flash-20261106-protocol-proteingym-paired-difference.
Source locator: Section 4.1; Appendix A 'Statistics'
Related records
- part of: HyPLM technical report protein language model evaluation
- uses data: ProteinGym DMS substitution assays at commit 144fe22 (217 assays)
- assessment: DPLM-650M on proteingym-paired-difference (HyPLM report)
- assessment: E1-600M on proteingym-paired-difference (HyPLM report)
- assessment: ESM-2 650M on proteingym-paired-difference (HyPLM report)
- assessment: ESM C 600M on proteingym-paired-difference (HyPLM report)