rewirebio.iobenchmarks
Protocol

Embedding throughput on one NVIDIA H20 (HyPLM report)

Measure how many residues per second a model embeds on one GPU for a fixed workload.

1 evaluation · 1 result

Overview

An explanatory profile has not yet been reviewed for this record.

Consult the linked sources for architecture or protocol details. Missing evidence is not evidence of a missing capability.

1 recorded evaluation, 1 metric rows. A comparison chart has not yet been validated for these results. The table retains the individual findings and their sources.

View coverage and remaining gaps across all benchmarks

Results

Results are available, but no reviewed comparison panel is linked in this release.

All evaluations

1 evaluation · 1 result. Different protocols are not a single leaderboard.

Filter evaluations

Applied filters: All linked evaluations

Exact evaluated configurations and original reported results
Tested configurationProtocol and datasetFindingEvidence and details
Configuration: HyPLM-Flash, INT8 inference engine (HyPLM report)Protocol: Embedding throughput on one NVIDIA H20 (HyPLM report)
Dataset: Throughput workload of 2,048 held-out proteins (HyPLM report)
131,000 Inference throughput (Residues embedded per second on one NVIDIA H20 for 2,048 held-out proteins (639,806 residues) in length-sorted batches of at most 16,384 tokens; HyPLM-Flash on its INT8 engine, where INT8 applies only to packed batches of at least 1,024 tokens)
sample-per-second · higher

Uncertainty: Not reported by the source: Section 4 says intervals are paired bootstrap intervals; none is printed here.

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

INT8 on embedding-throughput-h20 (HyPLM report)

hyplm-flash-20261106-protocol-embedding-throughput-h20

Aggregation: Not reported

HyPLM Technical Report (Hyra Team, 2026-10-12) · Section 3, sentence 'On a common workload of 2,048 held-out proteins, the engine embeds 131,000 residues per second on one H20' (page 4 of 13)

Source checking is not independent reproduction. Release 2026-11-21-adc15377fab2.

Methods and evaluation design

Procedure, tasks and evaluated configurations

Recorded evaluations

Each evaluation records what was tested and under which conditions.

Baseline coverage

Reference methods help show what a model adds beyond simple controls. We track a null control and a conventional method for each protocol.

0 of 2 active baseline roles have published Rewire measurements in this release. Measurements on a selected protocol do not establish coverage of an entire suite.

No execution recipe linked to this protocol. Recipe availability does not establish a completed evaluation.

Author-reported evaluations
1

Literature evidence is not a Rewire measurement. Executed but unpublished runs and private review status are not included.

Null control

Proposed control: requires review

Select a task-valid null control after reviewing inputs and metric

Protocol-specific applicability, permitted inputs, access, split, evaluator and execution requirements need review before implementation or execution.

This is a suggested selection rule, not a validated method or a measured score.

Conventional reference

Proposed control: requires review

Select an upstream conventional reference after reviewing the full protocol

Protocol-specific applicability, permitted inputs, access, split, evaluator and execution requirements need review before implementation or execution.

This is a suggested selection rule, not a validated method or a measured score.

Protocol coverage CSV (gzip) · Model evaluation matrix (gzip) · Source table (gzip) · Release and checksums (gzip)

Coverage is derived from release 2026-11-21-adc15377fab2. Source citations describe the original records; they do not validate an unreviewed baseline proposal. No results have been generated by this audit.

Run instructions

No runnable recipe has been reviewed for this protocol. Dataset access, model requirements, licences and compute requirements must be checked against its sources before execution.

Evidence

Source checking verifies the cited claim or transcription. It does not establish independent reproduction.

Evidence table

Inspect claims, sources and review details

Trace each statement to its source and review. A context-only reference supports the record generally; it does not verify an individual field. Source checking does not reproduce an experiment.

One row per statement and cited source. Multiple citations are not independent evaluations. Shared locators are labelled explicitly.

0 evidence rows matching the loaded filters

Claims, original sources and review scope · Release 2026-11-21-adc15377fab2
Property and statementOriginal source and locationReview and provenance

No evidence rows match these filters. Choose another scope or clear the search.

Sources and history

Release 2026-11-21-adc15377fab2 · Record review: source checked

1 source record and release historyDownload this release (gzip)
Technical metadata and record identifiers

Technical metadata for this record is tracked under stable ID hyplm-flash-20261106-protocol-embedding-throughput-h20.

Source locator: Section 3; Appendix A 'Throughput'

Related records

Suggest a correction