Protocol

ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3)

Run each tool on the 3,031 CNVs and compare its five-category output (benign, likely benign, VUS, likely pathogenic, pathogenic) with the expert classification; report accuracy, sensitivity, specificity, PPV, FPR, F1 and MCC.

5 evaluations · 35 results

Overview

An explanatory profile has not yet been reviewed for this record.

Consult the linked sources for architecture or protocol details. Missing evidence is not evidence of a missing capability.

5 recorded evaluations, 35 metric rows. A comparison chart has not yet been validated for these results. The table retains the individual findings and their sources.

View coverage and remaining gaps across all benchmarks

Results

Results are available, but no reviewed comparison panel is linked in this release.

All evaluations

5 evaluations · 35 results. Different protocols are not a single leaderboard.

Protocol: ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3) · Dataset: Expert-classified ACMG CNV benchmark (Zhang et al. 2026, 3,031 CNVs)

Sorted by Accuracy (ACMG five-category classification; averaging across classes not stated) (higher is better). The best value in each column is highlighted. Decimals are rounded for display; each value links to the printed value and its source.

Tested configurationAccuracy (ACMG five-category classification; averaging across classes not stated)F1 (ACMG five-category classification; averaging across classes not stated)False positive rate (ACMG five-category classification; averaging across classes not stated)MCC (ACMG five-category classification; averaging across classes not stated)Precision (ACMG five-category classification; averaging across classes not stated)Recall (ACMG five-category classification; averaging across classes not stated)Specificity (ACMG five-category classification; averaging across classes not stated)
MarCNV-ISV (Zhang et al. 2026)Evaluation69.8% (best in column)43.9%9.56%0.55 (best in column)46.8%45%90.4%
ClassifyCNV (Zhang et al. 2026)Evaluation67.8%45.1% (best in column)10.3%0.5452.3% (best in column)44%89.7%
dbCNV (Zhang et al. 2026)Evaluation66.6%41%9.4% (best in column)0.5140.9%45.7% (best in column)90.6% (best in column)
AnnotSV (Zhang et al. 2026)Evaluation60.2%38.1%11.2%0.4340%43.5%88.8%
X-CNV (Zhang et al. 2026)Evaluation48.8%34.5%12.7%0.3437%43.6%87.3%
All 35 result rows with coverage, uncertainty and sources
Filter evaluations

Applied filters: All linked evaluations

Exact evaluated configurations and original reported results
Tested configurationProtocol and datasetFindingEvidence and details
Configuration: AnnotSV (Zhang et al. 2026)Protocol: ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3)
Dataset: Expert-classified ACMG CNV benchmark (Zhang et al. 2026, 3,031 CNVs)
60.2% Accuracy (ACMG five-category classification; averaging across classes not stated)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

AnnotSV on the expert-classified ACMG CNV benchmark (five category)

cnv-20261011-zhang2026-protocol-five-category

Aggregation: Not reported

Can automated copy number variation pathogenicity prediction tools replace manual review under the ACMG framework? A clinical validation (Zhang, Zhang and Chen, Global Medical Genetics 2026) · Table 3, row 'AnnotSV', column 'Accuracy (%)'
Configuration: AnnotSV (Zhang et al. 2026)Protocol: ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3)
Dataset: Expert-classified ACMG CNV benchmark (Zhang et al. 2026, 3,031 CNVs)
38.1% F1 (ACMG five-category classification; averaging across classes not stated)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

AnnotSV on the expert-classified ACMG CNV benchmark (five category)

cnv-20261011-zhang2026-protocol-five-category

Aggregation: Not reported

Can automated copy number variation pathogenicity prediction tools replace manual review under the ACMG framework? A clinical validation (Zhang, Zhang and Chen, Global Medical Genetics 2026) · Table 3, row 'AnnotSV', column 'F1(%)'
Configuration: AnnotSV (Zhang et al. 2026)Protocol: ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3)
Dataset: Expert-classified ACMG CNV benchmark (Zhang et al. 2026, 3,031 CNVs)
11.2% False positive rate (ACMG five-category classification; averaging across classes not stated)
percent · lower

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

AnnotSV on the expert-classified ACMG CNV benchmark (five category)

cnv-20261011-zhang2026-protocol-five-category

Aggregation: Not reported

Can automated copy number variation pathogenicity prediction tools replace manual review under the ACMG framework? A clinical validation (Zhang, Zhang and Chen, Global Medical Genetics 2026) · Table 3, row 'AnnotSV', column 'FPR*(%)'
Configuration: AnnotSV (Zhang et al. 2026)Protocol: ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3)
Dataset: Expert-classified ACMG CNV benchmark (Zhang et al. 2026, 3,031 CNVs)
0.43 MCC (ACMG five-category classification; averaging across classes not stated)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

AnnotSV on the expert-classified ACMG CNV benchmark (five category)

cnv-20261011-zhang2026-protocol-five-category

Aggregation: Not reported

Can automated copy number variation pathogenicity prediction tools replace manual review under the ACMG framework? A clinical validation (Zhang, Zhang and Chen, Global Medical Genetics 2026) · Table 3, row 'AnnotSV', column 'MCC*'
Configuration: AnnotSV (Zhang et al. 2026)Protocol: ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3)
Dataset: Expert-classified ACMG CNV benchmark (Zhang et al. 2026, 3,031 CNVs)
40% Precision (ACMG five-category classification; averaging across classes not stated)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

AnnotSV on the expert-classified ACMG CNV benchmark (five category)

cnv-20261011-zhang2026-protocol-five-category

Aggregation: Not reported

Can automated copy number variation pathogenicity prediction tools replace manual review under the ACMG framework? A clinical validation (Zhang, Zhang and Chen, Global Medical Genetics 2026) · Table 3, row 'AnnotSV', column 'PPV*(%)'
Configuration: AnnotSV (Zhang et al. 2026)Protocol: ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3)
Dataset: Expert-classified ACMG CNV benchmark (Zhang et al. 2026, 3,031 CNVs)
43.5% Recall (ACMG five-category classification; averaging across classes not stated)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

AnnotSV on the expert-classified ACMG CNV benchmark (five category)

cnv-20261011-zhang2026-protocol-five-category

Aggregation: Not reported

Can automated copy number variation pathogenicity prediction tools replace manual review under the ACMG framework? A clinical validation (Zhang, Zhang and Chen, Global Medical Genetics 2026) · Table 3, row 'AnnotSV', column 'Sensitivity (%)'
Configuration: AnnotSV (Zhang et al. 2026)Protocol: ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3)
Dataset: Expert-classified ACMG CNV benchmark (Zhang et al. 2026, 3,031 CNVs)
88.8% Specificity (ACMG five-category classification; averaging across classes not stated)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

AnnotSV on the expert-classified ACMG CNV benchmark (five category)

cnv-20261011-zhang2026-protocol-five-category

Aggregation: Not reported

Can automated copy number variation pathogenicity prediction tools replace manual review under the ACMG framework? A clinical validation (Zhang, Zhang and Chen, Global Medical Genetics 2026) · Table 3, row 'AnnotSV', column 'Specificity (%)'
Configuration: ClassifyCNV (Zhang et al. 2026)Protocol: ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3)
Dataset: Expert-classified ACMG CNV benchmark (Zhang et al. 2026, 3,031 CNVs)
67.8% Accuracy (ACMG five-category classification; averaging across classes not stated)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

ClassifyCNV on the expert-classified ACMG CNV benchmark (five category)

cnv-20261011-zhang2026-protocol-five-category

Aggregation: Not reported

Can automated copy number variation pathogenicity prediction tools replace manual review under the ACMG framework? A clinical validation (Zhang, Zhang and Chen, Global Medical Genetics 2026) · Table 3, row 'ClassifyCNV', column 'Accuracy (%)'
Configuration: ClassifyCNV (Zhang et al. 2026)Protocol: ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3)
Dataset: Expert-classified ACMG CNV benchmark (Zhang et al. 2026, 3,031 CNVs)
45.1% F1 (ACMG five-category classification; averaging across classes not stated)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

ClassifyCNV on the expert-classified ACMG CNV benchmark (five category)

cnv-20261011-zhang2026-protocol-five-category

Aggregation: Not reported

Can automated copy number variation pathogenicity prediction tools replace manual review under the ACMG framework? A clinical validation (Zhang, Zhang and Chen, Global Medical Genetics 2026) · Table 3, row 'ClassifyCNV', column 'F1(%)'
Configuration: ClassifyCNV (Zhang et al. 2026)Protocol: ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3)
Dataset: Expert-classified ACMG CNV benchmark (Zhang et al. 2026, 3,031 CNVs)
10.3% False positive rate (ACMG five-category classification; averaging across classes not stated)
percent · lower

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

ClassifyCNV on the expert-classified ACMG CNV benchmark (five category)

cnv-20261011-zhang2026-protocol-five-category

Aggregation: Not reported

Can automated copy number variation pathogenicity prediction tools replace manual review under the ACMG framework? A clinical validation (Zhang, Zhang and Chen, Global Medical Genetics 2026) · Table 3, row 'ClassifyCNV', column 'FPR*(%)'
Configuration: ClassifyCNV (Zhang et al. 2026)Protocol: ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3)
Dataset: Expert-classified ACMG CNV benchmark (Zhang et al. 2026, 3,031 CNVs)
0.54 MCC (ACMG five-category classification; averaging across classes not stated)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

ClassifyCNV on the expert-classified ACMG CNV benchmark (five category)

cnv-20261011-zhang2026-protocol-five-category

Aggregation: Not reported

Can automated copy number variation pathogenicity prediction tools replace manual review under the ACMG framework? A clinical validation (Zhang, Zhang and Chen, Global Medical Genetics 2026) · Table 3, row 'ClassifyCNV', column 'MCC*'
Configuration: ClassifyCNV (Zhang et al. 2026)Protocol: ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3)
Dataset: Expert-classified ACMG CNV benchmark (Zhang et al. 2026, 3,031 CNVs)
52.3% Precision (ACMG five-category classification; averaging across classes not stated)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

ClassifyCNV on the expert-classified ACMG CNV benchmark (five category)

cnv-20261011-zhang2026-protocol-five-category

Aggregation: Not reported

Can automated copy number variation pathogenicity prediction tools replace manual review under the ACMG framework? A clinical validation (Zhang, Zhang and Chen, Global Medical Genetics 2026) · Table 3, row 'ClassifyCNV', column 'PPV*(%)'
Configuration: ClassifyCNV (Zhang et al. 2026)Protocol: ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3)
Dataset: Expert-classified ACMG CNV benchmark (Zhang et al. 2026, 3,031 CNVs)
44% Recall (ACMG five-category classification; averaging across classes not stated)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

ClassifyCNV on the expert-classified ACMG CNV benchmark (five category)

cnv-20261011-zhang2026-protocol-five-category

Aggregation: Not reported

Can automated copy number variation pathogenicity prediction tools replace manual review under the ACMG framework? A clinical validation (Zhang, Zhang and Chen, Global Medical Genetics 2026) · Table 3, row 'ClassifyCNV', column 'Sensitivity (%)'
Configuration: ClassifyCNV (Zhang et al. 2026)Protocol: ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3)
Dataset: Expert-classified ACMG CNV benchmark (Zhang et al. 2026, 3,031 CNVs)
89.7% Specificity (ACMG five-category classification; averaging across classes not stated)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

ClassifyCNV on the expert-classified ACMG CNV benchmark (five category)

cnv-20261011-zhang2026-protocol-five-category

Aggregation: Not reported

Can automated copy number variation pathogenicity prediction tools replace manual review under the ACMG framework? A clinical validation (Zhang, Zhang and Chen, Global Medical Genetics 2026) · Table 3, row 'ClassifyCNV', column 'Specificity (%)'
Configuration: dbCNV (Zhang et al. 2026)Protocol: ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3)
Dataset: Expert-classified ACMG CNV benchmark (Zhang et al. 2026, 3,031 CNVs)
66.6% Accuracy (ACMG five-category classification; averaging across classes not stated)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

dbCNV on the expert-classified ACMG CNV benchmark (five category)

cnv-20261011-zhang2026-protocol-five-category

Aggregation: Not reported

Can automated copy number variation pathogenicity prediction tools replace manual review under the ACMG framework? A clinical validation (Zhang, Zhang and Chen, Global Medical Genetics 2026) · Table 3, row 'dbCNV', column 'Accuracy (%)'
Configuration: dbCNV (Zhang et al. 2026)Protocol: ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3)
Dataset: Expert-classified ACMG CNV benchmark (Zhang et al. 2026, 3,031 CNVs)
41% F1 (ACMG five-category classification; averaging across classes not stated)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

dbCNV on the expert-classified ACMG CNV benchmark (five category)

cnv-20261011-zhang2026-protocol-five-category

Aggregation: Not reported

Can automated copy number variation pathogenicity prediction tools replace manual review under the ACMG framework? A clinical validation (Zhang, Zhang and Chen, Global Medical Genetics 2026) · Table 3, row 'dbCNV', column 'F1(%)'
Configuration: dbCNV (Zhang et al. 2026)Protocol: ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3)
Dataset: Expert-classified ACMG CNV benchmark (Zhang et al. 2026, 3,031 CNVs)
9.4% False positive rate (ACMG five-category classification; averaging across classes not stated)
percent · lower

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

dbCNV on the expert-classified ACMG CNV benchmark (five category)

cnv-20261011-zhang2026-protocol-five-category

Aggregation: Not reported

Can automated copy number variation pathogenicity prediction tools replace manual review under the ACMG framework? A clinical validation (Zhang, Zhang and Chen, Global Medical Genetics 2026) · Table 3, row 'dbCNV', column 'FPR*(%)'
Configuration: dbCNV (Zhang et al. 2026)Protocol: ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3)
Dataset: Expert-classified ACMG CNV benchmark (Zhang et al. 2026, 3,031 CNVs)
0.51 MCC (ACMG five-category classification; averaging across classes not stated)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

dbCNV on the expert-classified ACMG CNV benchmark (five category)

cnv-20261011-zhang2026-protocol-five-category

Aggregation: Not reported

Can automated copy number variation pathogenicity prediction tools replace manual review under the ACMG framework? A clinical validation (Zhang, Zhang and Chen, Global Medical Genetics 2026) · Table 3, row 'dbCNV', column 'MCC*'
Configuration: dbCNV (Zhang et al. 2026)Protocol: ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3)
Dataset: Expert-classified ACMG CNV benchmark (Zhang et al. 2026, 3,031 CNVs)
40.9% Precision (ACMG five-category classification; averaging across classes not stated)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

dbCNV on the expert-classified ACMG CNV benchmark (five category)

cnv-20261011-zhang2026-protocol-five-category

Aggregation: Not reported

Can automated copy number variation pathogenicity prediction tools replace manual review under the ACMG framework? A clinical validation (Zhang, Zhang and Chen, Global Medical Genetics 2026) · Table 3, row 'dbCNV', column 'PPV*(%)'
Configuration: dbCNV (Zhang et al. 2026)Protocol: ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3)
Dataset: Expert-classified ACMG CNV benchmark (Zhang et al. 2026, 3,031 CNVs)
45.7% Recall (ACMG five-category classification; averaging across classes not stated)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

dbCNV on the expert-classified ACMG CNV benchmark (five category)

cnv-20261011-zhang2026-protocol-five-category

Aggregation: Not reported

Can automated copy number variation pathogenicity prediction tools replace manual review under the ACMG framework? A clinical validation (Zhang, Zhang and Chen, Global Medical Genetics 2026) · Table 3, row 'dbCNV', column 'Sensitivity (%)'
Configuration: dbCNV (Zhang et al. 2026)Protocol: ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3)
Dataset: Expert-classified ACMG CNV benchmark (Zhang et al. 2026, 3,031 CNVs)
90.6% Specificity (ACMG five-category classification; averaging across classes not stated)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

dbCNV on the expert-classified ACMG CNV benchmark (five category)

cnv-20261011-zhang2026-protocol-five-category

Aggregation: Not reported

Can automated copy number variation pathogenicity prediction tools replace manual review under the ACMG framework? A clinical validation (Zhang, Zhang and Chen, Global Medical Genetics 2026) · Table 3, row 'dbCNV', column 'Specificity (%)'
Configuration: MarCNV-ISV (Zhang et al. 2026)Protocol: ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3)
Dataset: Expert-classified ACMG CNV benchmark (Zhang et al. 2026, 3,031 CNVs)
69.8% Accuracy (ACMG five-category classification; averaging across classes not stated)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

MarCNV-ISV on the expert-classified ACMG CNV benchmark (five category)

cnv-20261011-zhang2026-protocol-five-category

Aggregation: Not reported

Can automated copy number variation pathogenicity prediction tools replace manual review under the ACMG framework? A clinical validation (Zhang, Zhang and Chen, Global Medical Genetics 2026) · Table 3, row 'MarCNV-ISV', column 'Accuracy (%)'
Configuration: MarCNV-ISV (Zhang et al. 2026)Protocol: ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3)
Dataset: Expert-classified ACMG CNV benchmark (Zhang et al. 2026, 3,031 CNVs)
43.9% F1 (ACMG five-category classification; averaging across classes not stated)
percent · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

MarCNV-ISV on the expert-classified ACMG CNV benchmark (five category)

cnv-20261011-zhang2026-protocol-five-category

Aggregation: Not reported

Can automated copy number variation pathogenicity prediction tools replace manual review under the ACMG framework? A clinical validation (Zhang, Zhang and Chen, Global Medical Genetics 2026) · Table 3, row 'MarCNV-ISV', column 'F1(%)'
Configuration: MarCNV-ISV (Zhang et al. 2026)Protocol: ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3)
Dataset: Expert-classified ACMG CNV benchmark (Zhang et al. 2026, 3,031 CNVs)
9.56% False positive rate (ACMG five-category classification; averaging across classes not stated)
percent · lower

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

MarCNV-ISV on the expert-classified ACMG CNV benchmark (five category)

cnv-20261011-zhang2026-protocol-five-category

Aggregation: Not reported

Can automated copy number variation pathogenicity prediction tools replace manual review under the ACMG framework? A clinical validation (Zhang, Zhang and Chen, Global Medical Genetics 2026) · Table 3, row 'MarCNV-ISV', column 'FPR*(%)'
Configuration: MarCNV-ISV (Zhang et al. 2026)Protocol: ACMG five-category CNV pathogenicity classification against expert labels (Zhang et al. Table 3)
Dataset: Expert-classified ACMG CNV benchmark (Zhang et al. 2026, 3,031 CNVs)
0.55 MCC (ACMG five-category classification; averaging across classes not stated)
unitless · higher

Uncertainty: Not reported by the source

Coverage: Not reported scored / Not reported eligible

Independent external evaluation · Source checked
Methods, coverage and source

MarCNV-ISV on the expert-classified ACMG CNV benchmark (five category)

cnv-20261011-zhang2026-protocol-five-category

Aggregation: Not reported

Can automated copy number variation pathogenicity prediction tools replace manual review under the ACMG framework? A clinical validation (Zhang, Zhang and Chen, Global Medical Genetics 2026) · Table 3, row 'MarCNV-ISV', column 'MCC*'

Source checking is not independent reproduction. Release 2026-11-02-a7f03c9e55a5.

Methods and evaluation design

Procedure, tasks and evaluated configurations

Recorded evaluations

Each evaluation records what was tested and under which conditions.

Baseline coverage

Reference methods help show what a model adds beyond simple controls. We track a null control and a conventional method for each protocol.

0 of 2 active baseline roles have published Rewire measurements in this release. Measurements on a selected protocol do not establish coverage of an entire suite.

No execution recipe linked to this protocol. Recipe availability does not establish a completed evaluation.

Author-reported evaluations
1
External evaluations
4

Literature evidence is not a Rewire measurement. Executed but unpublished runs and private review status are not included.

Null control

Proposed control: requires review

Training-set class prior where supervised fitting is permitted

Protocol-specific applicability, permitted inputs, access, split, evaluator and execution requirements need review before implementation or execution.

This is a suggested selection rule, not a validated method or a measured score.

Conventional reference

Proposed control: requires review

Regularised classifier on simple permitted features, or protocol's conventional reference

Protocol-specific applicability, permitted inputs, access, split, evaluator and execution requirements need review before implementation or execution.

This is a suggested selection rule, not a validated method or a measured score.

Protocol coverage CSV (gzip) · Model evaluation matrix (gzip) · Source table (gzip) · Release and checksums (gzip)

Coverage is derived from release 2026-11-02-a7f03c9e55a5. Source citations describe the original records; they do not validate an unreviewed baseline proposal. No results have been generated by this audit.

Run instructions

No runnable recipe has been reviewed for this protocol. Dataset access, model requirements, licences and compute requirements must be checked against its sources before execution.

Evidence

Source checking verifies the cited claim or transcription. It does not establish independent reproduction.

Evidence table

Inspect claims, sources and review details

Trace each statement to its source and review. A context-only reference supports the record generally; it does not verify an individual field. Source checking does not reproduce an experiment.

One row per statement and cited source. Multiple citations are not independent evaluations. Shared locators are labelled explicitly.

0 evidence rows matching the loaded filters

Claims, original sources and review scope · Release 2026-11-02-a7f03c9e55a5
Property and statementOriginal source and locationReview and provenance

No evidence rows match these filters. Choose another scope or clear the search.

Sources and history

Release 2026-11-02-a7f03c9e55a5 · Record review: source checked

1 source record and release historyDownload this release (gzip)
Technical metadata and extraction receipts

Stable ID: cnv-20261011-zhang2026-protocol-five-category

areas
dna-genomes
contexts
clinical_research
protocol
Run each tool on the 3,031 CNVs and compare its five-category output (benign, likely benign, VUS, likely pathogenic, pathogenic) with the expert classification; report accuracy, sensitivity, specificity, PPV, FPR, F1 and MCC.
version
Table 3
source locator
Table 3; Methods 'Data analysis'; Results 'Comparative analysis of clinical metrics'
limitations
How the five-class metrics are averaged across classes is not stated.; Reference labels are expert ACMG classifications, a semi-quantitative standard with known inter-reviewer variability (Discussion paragraph 5).; The set is enriched for pregnancy-loss and prenatal cases and is imbalanced (benign is about half of the duplications), which the authors say affects the metrics (Discussion paragraphs 5 and 6).; Classification of already detected CNVs from their coordinates; no read data or detection step is evaluated.; Some training sets of the evaluated tools (ClinVar, ClinGen, DGV) may overlap the published cohorts used as reference; the paper does not test this.; Two of the three authors (X. Zhang and D. Chen) are authors of dbCNV (reference 24), developed in the same laboratory, so the dbCNV rows are author_reported. dbCNV's original test set was that laboratory's internal dataset, and this benchmark includes the laboratory's internal CNV-seq cases (December 2019 to November 2025); overlap is not tested. The paper declares no competing interests.
Related records

Suggest a correction