rewirebio.iobenchmarks
Method

CADD input feature (-) Freq100bp

Negated count of common variants within 100 bp of the variant, as distributed in the CADD v1.7 annotation bundle, used directly as a variant score.

1 evaluation · 1 result

Overview

An explanatory profile has not yet been reviewed for this record.

Consult the linked sources for architecture or protocol details. Missing evidence is not evidence of a missing capability.

Model Capabilities & Hardware Requirements

Deployment facts recorded for CADD input feature (-) Freq100bp. Fields the record does not carry are marked not recorded.

ParametersNot recorded
Minimum VRAMNot recorded
Inference LatencyNot recorded
Context WindowNot recorded
AccessNot recorded
LicenseNot recorded

Evaluated Checkpoint: CADD v1.7 annotation bundle (whole_genome_SNVs_inclAnno.tsv.gz, GRCh38)

Evaluations and results

1 evaluation · 1 result. Different protocols are not a single leaderboard.

Filter evaluations

Applied filters: All linked evaluations

Exact evaluated configurations and original reported results
Tested configurationProtocol and datasetFindingEvidence and details
Method: CADD input feature (-) Freq100bpProtocol: TraitGym Mendelian traits, AUPRC of a single CADD input feature
Dataset: TraitGym Mendelian traits, matched 9 controls
0.509 AUPRC (single CADD input feature as the score; chromosome aggregation unreported)
unitless · higher

Uncertainty: Not reported by the source: The table prints no standard error; the bootstrap errors of Appendix B.4 are reported only in the figures.

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

CADD input feature (-) Freq100bp on TraitGym Mendelian traits

traitgym-20261116-protocol-mendelian-single-cadd-input-feature-auprc

Aggregation: Not reported

Benegas, Eraslan and Song 2025, TraitGym benchmark preprint (bioRxiv v2) · Table 4, row "(-) Freq100bp", column "AUPRC" (page 12)

Source checking is not independent reproduction. Release 2026-11-21-adc15377fab2.

Use this method

How it works, versions and access

Additional methodological details, versions and access terms have not yet been extracted into a structured profile for this method. Consult the linked sources and evaluation records below.

Evidence

Source checking verifies the cited claim or transcription. It does not establish independent reproduction.

Evidence table

Inspect claims, sources and review details

Trace each statement to its source and review. A context-only reference supports the record generally; it does not verify an individual field. Source checking does not reproduce an experiment.

One row per statement and cited source. Multiple citations are not independent evaluations. Shared locators are labelled explicitly.

0 evidence rows matching the loaded filters

Claims, original sources and review scope · Release 2026-11-21-adc15377fab2
Property and statementOriginal source and locationReview and provenance

No evidence rows match these filters. Choose another scope or clear the search.

Sources and history

Release 2026-11-21-adc15377fab2 · Record review: source checked

1 source record and release historyDownload this release (gzip)
Technical metadata and record identifiers

Technical metadata for this record is tracked under stable ID traitgym-20261116-method-cadd-feature-freq100bp.

Source locator: Table 4, row "(-) Freq100bp" (page 12); Appendix B.1 for the CADD version

Related records

How to cite

CADD input feature (-) Freq100bp. Rewire biological model benchmark database, release 2026-11-21-adc15377fab2. https://benchmarks.rewirebio.io/database/method/traitgym-20261116-method-cadd-feature-freq100bp/

Release 2026-11-21-adc15377fab2. Rankings and values change between releases, so keep the release id in the citation. Cite the original publication as well for any value you reuse: each result links its source.

The compilation and annotations made by Rewire in this release are offered under CC BY 4.0; values and text taken from cited sources stay under the terms of those sources and are not covered by this licence. Data licence

Suggest a correction