ESM C 300M (HyPLM report)
Runs the public ESM C 300M checkpoint in BF16 through the esm package to produce embeddings, probe features and masked-language-model scores.
Overview
An explanatory profile has not yet been reviewed for this record.
Consult the linked sources for architecture or protocol details. Missing evidence is not evidence of a missing capability.
Model Capabilities & Hardware Requirements
Deployment facts recorded for ESM C 300M (HyPLM report). Fields the record does not carry are marked not recorded.
Evaluated Checkpoint: Public ESM C 300M checkpoint; no revision printed
Evaluations and results
1 evaluation · 1 result. Different protocols are not a single leaderboard.
Filter evaluations
Applied filters: All linked evaluations
| Tested configuration | Protocol and dataset | Finding | Evidence and details |
|---|---|---|---|
| Configuration: ESM C 300M (HyPLM report) | Protocol: ProteinGym zero-shot (HyPLM report) Dataset subset: ProteinGym DMS substitution assays at commit 144fe22 (217 assays) | 0.406 Spearman (Spearman correlation averaged over the 217 substitution assays of ProteinGym v1.3 with the benchmark's official aggregation, from masked-marginal zero-shot scores; per-assay values rounded to three decimals before aggregation) unitless · higher Uncertainty: Not reported by the source: Section 4 says intervals are paired bootstrap intervals; none is printed here. Coverage: Not reported scored / Not reported eligible | Author-reported evaluation · Source checkedMethods, coverage and sourceESM C 300M on proteingym-zero-shot (HyPLM report) hyplm-flash-20261106-protocol-proteingym-zero-shot Aggregation: Not reported HyPLM Technical Report (Hyra Team, 2026-10-12) · Figure 3a, bar 'ESM C 300M', printed value label (page 5 of 13) |
Source checking is not independent reproduction. Release 2026-11-21-adc15377fab2.
Use this configuration
How it works, versions and access
Additional methodological details, versions and access terms have not yet been extracted into a structured profile for this configuration. Consult the linked sources and evaluation records below.
Evidence
Source checking verifies the cited claim or transcription. It does not establish independent reproduction.
Evidence table
Inspect claims, sources and review details
Trace each statement to its source and review. A context-only reference supports the record generally; it does not verify an individual field. Source checking does not reproduce an experiment.
One row per statement and cited source. Multiple citations are not independent evaluations. Shared locators are labelled explicitly.
0 evidence rows matching the loaded filters
| Property and statement | Original source and location | Review and provenance |
|---|
No evidence rows match these filters. Choose another scope or clear the search.
Sources and history
Release 2026-11-21-adc15377fab2 · Record review: source checked
1 source record and release history
- HyPLM Technical Report (Hyra Team, 2026-10-12) · Original source · Dated 2026-10-12 on page 1; retrieved at commit 0dcc533cc9f8f76c90ecbfe944df816b6672328a (13 pages)
Technical metadata and record identifiers
Technical metadata for this record is tracked under stable ID hyplm-flash-20261106-config-esm-c-300m.
Source locator: Appendix A 'Models' and 'Deviations'; Section 4
Related records
- configuration of: ESMC
- system: ESM C 300M on proteingym-zero-shot (HyPLM report)
How to cite
ESM C 300M (HyPLM report). Rewire biological model benchmark database, release 2026-11-21-adc15377fab2. https://benchmarks.rewirebio.io/database/configuration/hyplm-flash-20261106-config-esm-c-300m/
Release 2026-11-21-adc15377fab2. Rankings and values change between releases, so keep the release id in the citation. Cite the original publication as well for any value you reuse: each result links its source.
The compilation and annotations made by Rewire in this release are offered under CC BY 4.0; values and text taken from cited sources stay under the terms of those sources and are not covered by this licence. Data licence