Configuration: HyInv default (HyInv report) Protocol: CA-lDDT of designed sequences under ESMFold2 (HyInv report) Dataset: CATH4.2 test (1,120 chains) 0.871 lDDT (CA-only lDDT-style score without superposition, over all CA pairs below 15 Angstrom in the native structure, as the fraction whose distance error is below 0.5, 1, 2 and 4 Angstrom averaged over the four thresholds with the pairs pooled over the whole design; between 0 and 1)unitless · higher
Uncertainty: Not reported by the source
Coverage: Not reported scored / Not reported eligible
Author-reported evaluation · Source checked Evidence concern: excluded from comparisons Appendix C states 'We do not claim zero sequence overlap between the training data and the evaluation panels', and Appendix G's homology screen is a coverage rule under which partial hits remain (Table 10: 28 of 74 de novo backbones and 7 of 12 pocket backbones have partial hits, and all 4 named enzymes are homologous to training data by design). Results on these panels are therefore not clean held-out measurements and must not be compared with results from sources that do establish no overlap.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix C 'Data and pool', final bullet; Appendix G 'Homology of the panels' and Table 10
The ten baselines are single published settings at one temperature each, so their design-set diversity differs from HyInv's: on CATH4.3 test HyInv samples at diversity 0.331 against 0.093 for PiFold, 0.104 for CMLM, 0.144 for LM-Design 650M and 0.000 for DPLM-2 3B, which decodes by argmax. Appendix D.2 states that these four differences are not at matched diversity, and Appendix A states that even for the closest baselines the comparisons are 'close to, but not exactly at, equal diversity', the largest offset of 0.016 being worth at most 0.0011 scTM at the development slope. The scTM and scTM difference results of the protocols named here must not be read as a matched-diversity ranking. The results read at a stated diversity level (Tables 8 and 9 and Appendix D.3) are not covered by this entry, because they are the ones the report reads on a fitted curve at a fixed diversity; nor are the recovery, diversity, pLDDT, scRMSD and lDDT results, whose protocols carry the same single-setting caveat in their own limitations and whose metric qualifiers say the value is at each method's own setting.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.1 and D.2; Table 7; Figure 14 diversity block; Section 5.1 'Baselines' and 'HyInv'
The inference-time results were measured with the supervised-stage weights and a rewrite temperature of 0.23, not with the released checkpoint and its default temperatures, and the quality read-outs of the two numerical paths used the RL checkpoint at update 288, not update 640. Speed and quality in this report are therefore measured on different weights, and the 57x figure compares HyInv's optimised BF16 path with ProteinMPNN's released implementation rather than with an equally optimised baseline.HyInv Technical Report (Hyra Team, 2026-10-14) · Table 1 footnote; Appendix F 'Timing protocol' and 'Baseline timings'
Methods, coverage and source HyInv on CATH4.2 test (CA-lDDT of designed sequences under ESMFold2, HyInv report)
hyinv-20261106-protocol-lddt-esmfold2
Aggregation: Not reported
HyInv Technical Report (Hyra Team, 2026-10-14) · Figure 15, 'CA-lDDT' block, row 'HyInv', column 'CATH4.2 test' (page 17 of 21) Configuration: HyInv default (HyInv report) Protocol: CA-lDDT of designed sequences under ESMFold2 (HyInv report) Dataset: CATH4.3 test (1,882 chains) 0.868 lDDT (CA-only lDDT-style score without superposition, over all CA pairs below 15 Angstrom in the native structure, as the fraction whose distance error is below 0.5, 1, 2 and 4 Angstrom averaged over the four thresholds with the pairs pooled over the whole design; between 0 and 1)unitless · higher
Uncertainty: Not reported by the source
Coverage: Not reported scored / Not reported eligible
Author-reported evaluation · Source checked Evidence concern: excluded from comparisons Appendix C states 'We do not claim zero sequence overlap between the training data and the evaluation panels', and Appendix G's homology screen is a coverage rule under which partial hits remain (Table 10: 28 of 74 de novo backbones and 7 of 12 pocket backbones have partial hits, and all 4 named enzymes are homologous to training data by design). Results on these panels are therefore not clean held-out measurements and must not be compared with results from sources that do establish no overlap.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix C 'Data and pool', final bullet; Appendix G 'Homology of the panels' and Table 10
The ten baselines are single published settings at one temperature each, so their design-set diversity differs from HyInv's: on CATH4.3 test HyInv samples at diversity 0.331 against 0.093 for PiFold, 0.104 for CMLM, 0.144 for LM-Design 650M and 0.000 for DPLM-2 3B, which decodes by argmax. Appendix D.2 states that these four differences are not at matched diversity, and Appendix A states that even for the closest baselines the comparisons are 'close to, but not exactly at, equal diversity', the largest offset of 0.016 being worth at most 0.0011 scTM at the development slope. The scTM and scTM difference results of the protocols named here must not be read as a matched-diversity ranking. The results read at a stated diversity level (Tables 8 and 9 and Appendix D.3) are not covered by this entry, because they are the ones the report reads on a fitted curve at a fixed diversity; nor are the recovery, diversity, pLDDT, scRMSD and lDDT results, whose protocols carry the same single-setting caveat in their own limitations and whose metric qualifiers say the value is at each method's own setting.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.1 and D.2; Table 7; Figure 14 diversity block; Section 5.1 'Baselines' and 'HyInv'
The inference-time results were measured with the supervised-stage weights and a rewrite temperature of 0.23, not with the released checkpoint and its default temperatures, and the quality read-outs of the two numerical paths used the RL checkpoint at update 288, not update 640. Speed and quality in this report are therefore measured on different weights, and the 57x figure compares HyInv's optimised BF16 path with ProteinMPNN's released implementation rather than with an equally optimised baseline.HyInv Technical Report (Hyra Team, 2026-10-14) · Table 1 footnote; Appendix F 'Timing protocol' and 'Baseline timings'
Methods, coverage and source HyInv on CATH4.3 test (CA-lDDT of designed sequences under ESMFold2, HyInv report)
hyinv-20261106-protocol-lddt-esmfold2
Aggregation: Not reported
HyInv Technical Report (Hyra Team, 2026-10-14) · Figure 15, 'CA-lDDT' block, row 'HyInv', column 'CATH4.3 test' (page 17 of 21) Configuration: HyInv default (HyInv report) Protocol: CA-lDDT of designed sequences under ESMFold2 (HyInv report) Dataset: RecentPDB (121 chains from 111 recent PDB entries) 0.88 lDDT (CA-only lDDT-style score without superposition, over all CA pairs below 15 Angstrom in the native structure, as the fraction whose distance error is below 0.5, 1, 2 and 4 Angstrom averaged over the four thresholds with the pairs pooled over the whole design; between 0 and 1)unitless · higher
Uncertainty: Not reported by the source
Coverage: Not reported scored / Not reported eligible
Author-reported evaluation · Source checked Evidence concern: excluded from comparisons Appendix C states 'We do not claim zero sequence overlap between the training data and the evaluation panels', and Appendix G's homology screen is a coverage rule under which partial hits remain (Table 10: 28 of 74 de novo backbones and 7 of 12 pocket backbones have partial hits, and all 4 named enzymes are homologous to training data by design). Results on these panels are therefore not clean held-out measurements and must not be compared with results from sources that do establish no overlap.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix C 'Data and pool', final bullet; Appendix G 'Homology of the panels' and Table 10
The ten baselines are single published settings at one temperature each, so their design-set diversity differs from HyInv's: on CATH4.3 test HyInv samples at diversity 0.331 against 0.093 for PiFold, 0.104 for CMLM, 0.144 for LM-Design 650M and 0.000 for DPLM-2 3B, which decodes by argmax. Appendix D.2 states that these four differences are not at matched diversity, and Appendix A states that even for the closest baselines the comparisons are 'close to, but not exactly at, equal diversity', the largest offset of 0.016 being worth at most 0.0011 scTM at the development slope. The scTM and scTM difference results of the protocols named here must not be read as a matched-diversity ranking. The results read at a stated diversity level (Tables 8 and 9 and Appendix D.3) are not covered by this entry, because they are the ones the report reads on a fitted curve at a fixed diversity; nor are the recovery, diversity, pLDDT, scRMSD and lDDT results, whose protocols carry the same single-setting caveat in their own limitations and whose metric qualifiers say the value is at each method's own setting.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.1 and D.2; Table 7; Figure 14 diversity block; Section 5.1 'Baselines' and 'HyInv'
The inference-time results were measured with the supervised-stage weights and a rewrite temperature of 0.23, not with the released checkpoint and its default temperatures, and the quality read-outs of the two numerical paths used the RL checkpoint at update 288, not update 640. Speed and quality in this report are therefore measured on different weights, and the 57x figure compares HyInv's optimised BF16 path with ProteinMPNN's released implementation rather than with an equally optimised baseline.HyInv Technical Report (Hyra Team, 2026-10-14) · Table 1 footnote; Appendix F 'Timing protocol' and 'Baseline timings'
Methods, coverage and source HyInv on RecentPDB (CA-lDDT of designed sequences under ESMFold2, HyInv report)
hyinv-20261106-protocol-lddt-esmfold2
Aggregation: Not reported
HyInv Technical Report (Hyra Team, 2026-10-14) · Figure 15, 'CA-lDDT' block, row 'HyInv', column 'RecentPDB' (page 17 of 21) Configuration: HyInv default (HyInv report) Protocol: CA-lDDT of designed sequences under ESMFold2 (HyInv report) Dataset: TS50 (50 chains) 0.908 lDDT (CA-only lDDT-style score without superposition, over all CA pairs below 15 Angstrom in the native structure, as the fraction whose distance error is below 0.5, 1, 2 and 4 Angstrom averaged over the four thresholds with the pairs pooled over the whole design; between 0 and 1)unitless · higher
Uncertainty: Not reported by the source
Coverage: Not reported scored / Not reported eligible
Author-reported evaluation · Source checked Evidence concern: excluded from comparisons Appendix C states 'We do not claim zero sequence overlap between the training data and the evaluation panels', and Appendix G's homology screen is a coverage rule under which partial hits remain (Table 10: 28 of 74 de novo backbones and 7 of 12 pocket backbones have partial hits, and all 4 named enzymes are homologous to training data by design). Results on these panels are therefore not clean held-out measurements and must not be compared with results from sources that do establish no overlap.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix C 'Data and pool', final bullet; Appendix G 'Homology of the panels' and Table 10
The ten baselines are single published settings at one temperature each, so their design-set diversity differs from HyInv's: on CATH4.3 test HyInv samples at diversity 0.331 against 0.093 for PiFold, 0.104 for CMLM, 0.144 for LM-Design 650M and 0.000 for DPLM-2 3B, which decodes by argmax. Appendix D.2 states that these four differences are not at matched diversity, and Appendix A states that even for the closest baselines the comparisons are 'close to, but not exactly at, equal diversity', the largest offset of 0.016 being worth at most 0.0011 scTM at the development slope. The scTM and scTM difference results of the protocols named here must not be read as a matched-diversity ranking. The results read at a stated diversity level (Tables 8 and 9 and Appendix D.3) are not covered by this entry, because they are the ones the report reads on a fitted curve at a fixed diversity; nor are the recovery, diversity, pLDDT, scRMSD and lDDT results, whose protocols carry the same single-setting caveat in their own limitations and whose metric qualifiers say the value is at each method's own setting.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.1 and D.2; Table 7; Figure 14 diversity block; Section 5.1 'Baselines' and 'HyInv'
The inference-time results were measured with the supervised-stage weights and a rewrite temperature of 0.23, not with the released checkpoint and its default temperatures, and the quality read-outs of the two numerical paths used the RL checkpoint at update 288, not update 640. Speed and quality in this report are therefore measured on different weights, and the 57x figure compares HyInv's optimised BF16 path with ProteinMPNN's released implementation rather than with an equally optimised baseline.HyInv Technical Report (Hyra Team, 2026-10-14) · Table 1 footnote; Appendix F 'Timing protocol' and 'Baseline timings'
Methods, coverage and source HyInv on TS50 (CA-lDDT of designed sequences under ESMFold2, HyInv report)
hyinv-20261106-protocol-lddt-esmfold2
Aggregation: Not reported
HyInv Technical Report (Hyra Team, 2026-10-14) · Figure 15, 'CA-lDDT' block, row 'HyInv', column 'TS50' (page 17 of 21) Configuration: HyInv default (HyInv report) Protocol: CA-lDDT of designed sequences under ESMFold2 (HyInv report) Dataset: TS500 (500 chains) 0.9 lDDT (CA-only lDDT-style score without superposition, over all CA pairs below 15 Angstrom in the native structure, as the fraction whose distance error is below 0.5, 1, 2 and 4 Angstrom averaged over the four thresholds with the pairs pooled over the whole design; between 0 and 1)unitless · higher
Uncertainty: Not reported by the source
Coverage: Not reported scored / Not reported eligible
Author-reported evaluation · Source checked Evidence concern: excluded from comparisons Appendix C states 'We do not claim zero sequence overlap between the training data and the evaluation panels', and Appendix G's homology screen is a coverage rule under which partial hits remain (Table 10: 28 of 74 de novo backbones and 7 of 12 pocket backbones have partial hits, and all 4 named enzymes are homologous to training data by design). Results on these panels are therefore not clean held-out measurements and must not be compared with results from sources that do establish no overlap.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix C 'Data and pool', final bullet; Appendix G 'Homology of the panels' and Table 10
The ten baselines are single published settings at one temperature each, so their design-set diversity differs from HyInv's: on CATH4.3 test HyInv samples at diversity 0.331 against 0.093 for PiFold, 0.104 for CMLM, 0.144 for LM-Design 650M and 0.000 for DPLM-2 3B, which decodes by argmax. Appendix D.2 states that these four differences are not at matched diversity, and Appendix A states that even for the closest baselines the comparisons are 'close to, but not exactly at, equal diversity', the largest offset of 0.016 being worth at most 0.0011 scTM at the development slope. The scTM and scTM difference results of the protocols named here must not be read as a matched-diversity ranking. The results read at a stated diversity level (Tables 8 and 9 and Appendix D.3) are not covered by this entry, because they are the ones the report reads on a fitted curve at a fixed diversity; nor are the recovery, diversity, pLDDT, scRMSD and lDDT results, whose protocols carry the same single-setting caveat in their own limitations and whose metric qualifiers say the value is at each method's own setting.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.1 and D.2; Table 7; Figure 14 diversity block; Section 5.1 'Baselines' and 'HyInv'
The inference-time results were measured with the supervised-stage weights and a rewrite temperature of 0.23, not with the released checkpoint and its default temperatures, and the quality read-outs of the two numerical paths used the RL checkpoint at update 288, not update 640. Speed and quality in this report are therefore measured on different weights, and the 57x figure compares HyInv's optimised BF16 path with ProteinMPNN's released implementation rather than with an equally optimised baseline.HyInv Technical Report (Hyra Team, 2026-10-14) · Table 1 footnote; Appendix F 'Timing protocol' and 'Baseline timings'
Methods, coverage and source HyInv on TS500 (CA-lDDT of designed sequences under ESMFold2, HyInv report)
hyinv-20261106-protocol-lddt-esmfold2
Aggregation: Not reported
HyInv Technical Report (Hyra Team, 2026-10-14) · Figure 15, 'CA-lDDT' block, row 'HyInv', column 'TS500' (page 17 of 21) Configuration: HyInv default (HyInv report) Protocol: Novel and foldable designs per de novo backbone at matched diversity (HyInv report) Dataset: De novo backbones application panel (74 backbones) 0.38 Count (Number of designs per backbone (of 4) that are both foldable (ESMFold2 scTM at least 0.9) and novel (sequence identity below 0.3 to the nearest UniRef50 sequence and to the nearest sequence of the pretraining library), at matched diversity; two readings, with and without the report's composition filter; the composition-filtered reading: sequence entropy at least 3.5 bits, hydrophobic fraction (AVILMFWY) 0.25 to 0.55, longest homopolymer run at most 6 The baselines are interpolated at the HyInv diversity from their own temperature grids, so 'at matched diversity' is the report's wording for an interpolated comparison and not a measurement of either baseline at HyInv's diversity.)count · higher
Uncertainty: Not reported by the source
Coverage: 74/74 backbones scored (58 clusters of 30% sequence identity; 4 designs per backbone.)
Author-reported evaluation · Source checked Evidence concern: excluded from comparisons Appendix C states 'We do not claim zero sequence overlap between the training data and the evaluation panels', and Appendix G's homology screen is a coverage rule under which partial hits remain (Table 10: 28 of 74 de novo backbones and 7 of 12 pocket backbones have partial hits, and all 4 named enzymes are homologous to training data by design). Results on these panels are therefore not clean held-out measurements and must not be compared with results from sources that do establish no overlap.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix C 'Data and pool', final bullet; Appendix G 'Homology of the panels' and Table 10
The ten baselines are single published settings at one temperature each, so their design-set diversity differs from HyInv's: on CATH4.3 test HyInv samples at diversity 0.331 against 0.093 for PiFold, 0.104 for CMLM, 0.144 for LM-Design 650M and 0.000 for DPLM-2 3B, which decodes by argmax. Appendix D.2 states that these four differences are not at matched diversity, and Appendix A states that even for the closest baselines the comparisons are 'close to, but not exactly at, equal diversity', the largest offset of 0.016 being worth at most 0.0011 scTM at the development slope. The scTM and scTM difference results of the protocols named here must not be read as a matched-diversity ranking. The results read at a stated diversity level (Tables 8 and 9 and Appendix D.3) are not covered by this entry, because they are the ones the report reads on a fitted curve at a fixed diversity; nor are the recovery, diversity, pLDDT, scRMSD and lDDT results, whose protocols carry the same single-setting caveat in their own limitations and whose metric qualifiers say the value is at each method's own setting.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.1 and D.2; Table 7; Figure 14 diversity block; Section 5.1 'Baselines' and 'HyInv'
The inference-time results were measured with the supervised-stage weights and a rewrite temperature of 0.23, not with the released checkpoint and its default temperatures, and the quality read-outs of the two numerical paths used the RL checkpoint at update 288, not update 640. Speed and quality in this report are therefore measured on different weights, and the 57x figure compares HyInv's optimised BF16 path with ProteinMPNN's released implementation rather than with an equally optimised baseline.HyInv Technical Report (Hyra Team, 2026-10-14) · Table 1 footnote; Appendix F 'Timing protocol' and 'Baseline timings'
Methods, coverage and source HyInv: novel and foldable designs per de novo backbone at matched diversity (HyInv report)
hyinv-20261106-protocol-novel-and-foldable-yield
Aggregation: Not reported
HyInv Technical Report (Hyra Team, 2026-10-14) · Section 6 'De novo backbones', sentence '0.68 unfiltered and 0.38 filtered per backbone, against 0.47 and 0.05 for ProteinMPNN and 0.45 and 0.11 for ProteinZero V2' (page 8 of 21) Configuration: HyInv default (HyInv report) Protocol: Novel and foldable designs per de novo backbone at matched diversity (HyInv report) Dataset: De novo backbones application panel (74 backbones) 0.68 Count (Number of designs per backbone (of 4) that are both foldable (ESMFold2 scTM at least 0.9) and novel (sequence identity below 0.3 to the nearest UniRef50 sequence and to the nearest sequence of the pretraining library), at matched diversity; two readings, with and without the report's composition filter; the unfiltered reading, over all designs The baselines are interpolated at the HyInv diversity from their own temperature grids, so 'at matched diversity' is the report's wording for an interpolated comparison and not a measurement of either baseline at HyInv's diversity.)count · higher
Uncertainty: Not reported by the source
Coverage: 74/74 backbones scored (58 clusters of 30% sequence identity; 4 designs per backbone.)
Author-reported evaluation · Source checked Evidence concern: excluded from comparisons Appendix C states 'We do not claim zero sequence overlap between the training data and the evaluation panels', and Appendix G's homology screen is a coverage rule under which partial hits remain (Table 10: 28 of 74 de novo backbones and 7 of 12 pocket backbones have partial hits, and all 4 named enzymes are homologous to training data by design). Results on these panels are therefore not clean held-out measurements and must not be compared with results from sources that do establish no overlap.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix C 'Data and pool', final bullet; Appendix G 'Homology of the panels' and Table 10
The ten baselines are single published settings at one temperature each, so their design-set diversity differs from HyInv's: on CATH4.3 test HyInv samples at diversity 0.331 against 0.093 for PiFold, 0.104 for CMLM, 0.144 for LM-Design 650M and 0.000 for DPLM-2 3B, which decodes by argmax. Appendix D.2 states that these four differences are not at matched diversity, and Appendix A states that even for the closest baselines the comparisons are 'close to, but not exactly at, equal diversity', the largest offset of 0.016 being worth at most 0.0011 scTM at the development slope. The scTM and scTM difference results of the protocols named here must not be read as a matched-diversity ranking. The results read at a stated diversity level (Tables 8 and 9 and Appendix D.3) are not covered by this entry, because they are the ones the report reads on a fitted curve at a fixed diversity; nor are the recovery, diversity, pLDDT, scRMSD and lDDT results, whose protocols carry the same single-setting caveat in their own limitations and whose metric qualifiers say the value is at each method's own setting.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.1 and D.2; Table 7; Figure 14 diversity block; Section 5.1 'Baselines' and 'HyInv'
The inference-time results were measured with the supervised-stage weights and a rewrite temperature of 0.23, not with the released checkpoint and its default temperatures, and the quality read-outs of the two numerical paths used the RL checkpoint at update 288, not update 640. Speed and quality in this report are therefore measured on different weights, and the 57x figure compares HyInv's optimised BF16 path with ProteinMPNN's released implementation rather than with an equally optimised baseline.HyInv Technical Report (Hyra Team, 2026-10-14) · Table 1 footnote; Appendix F 'Timing protocol' and 'Baseline timings'
Methods, coverage and source HyInv: novel and foldable designs per de novo backbone at matched diversity (HyInv report)
hyinv-20261106-protocol-novel-and-foldable-yield
Aggregation: Not reported
HyInv Technical Report (Hyra Team, 2026-10-14) · Section 6 'De novo backbones', sentence '0.68 unfiltered and 0.38 filtered per backbone, against 0.47 and 0.05 for ProteinMPNN and 0.45 and 0.11 for ProteinZero V2' (page 8 of 21) Configuration: HyInv default (HyInv report) Protocol: pLDDT of ESMFold2 predictions of designed sequences (HyInv report) Dataset: CATH4.2 test (1,120 chains) 84.2 Plddt (ESMFold2 mean per-residue confidence over valid sites on a scale from 0 to 100, averaged over the designs of a target and then over targets; from a second fold of the same sequences with the confidence head on)unitless · higher
Uncertainty: Not reported by the source
Coverage: Not reported scored / Not reported eligible
Author-reported evaluation · Source checked Evidence concern: excluded from comparisons Appendix C states 'We do not claim zero sequence overlap between the training data and the evaluation panels', and Appendix G's homology screen is a coverage rule under which partial hits remain (Table 10: 28 of 74 de novo backbones and 7 of 12 pocket backbones have partial hits, and all 4 named enzymes are homologous to training data by design). Results on these panels are therefore not clean held-out measurements and must not be compared with results from sources that do establish no overlap.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix C 'Data and pool', final bullet; Appendix G 'Homology of the panels' and Table 10
The ten baselines are single published settings at one temperature each, so their design-set diversity differs from HyInv's: on CATH4.3 test HyInv samples at diversity 0.331 against 0.093 for PiFold, 0.104 for CMLM, 0.144 for LM-Design 650M and 0.000 for DPLM-2 3B, which decodes by argmax. Appendix D.2 states that these four differences are not at matched diversity, and Appendix A states that even for the closest baselines the comparisons are 'close to, but not exactly at, equal diversity', the largest offset of 0.016 being worth at most 0.0011 scTM at the development slope. The scTM and scTM difference results of the protocols named here must not be read as a matched-diversity ranking. The results read at a stated diversity level (Tables 8 and 9 and Appendix D.3) are not covered by this entry, because they are the ones the report reads on a fitted curve at a fixed diversity; nor are the recovery, diversity, pLDDT, scRMSD and lDDT results, whose protocols carry the same single-setting caveat in their own limitations and whose metric qualifiers say the value is at each method's own setting.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.1 and D.2; Table 7; Figure 14 diversity block; Section 5.1 'Baselines' and 'HyInv'
The inference-time results were measured with the supervised-stage weights and a rewrite temperature of 0.23, not with the released checkpoint and its default temperatures, and the quality read-outs of the two numerical paths used the RL checkpoint at update 288, not update 640. Speed and quality in this report are therefore measured on different weights, and the 57x figure compares HyInv's optimised BF16 path with ProteinMPNN's released implementation rather than with an equally optimised baseline.HyInv Technical Report (Hyra Team, 2026-10-14) · Table 1 footnote; Appendix F 'Timing protocol' and 'Baseline timings'
Methods, coverage and source HyInv on CATH4.2 test (pLDDT of ESMFold2 predictions of designed sequences, HyInv report)
hyinv-20261106-protocol-plddt-esmfold2
Aggregation: Not reported
HyInv Technical Report (Hyra Team, 2026-10-14) · Figure 15, 'pLDDT' block, row 'HyInv', column 'CATH4.2 test' (page 17 of 21) Configuration: HyInv default (HyInv report) Protocol: pLDDT of ESMFold2 predictions of designed sequences (HyInv report) Dataset: CATH4.3 test (1,882 chains) 83.3 Plddt (ESMFold2 mean per-residue confidence over valid sites on a scale from 0 to 100, averaged over the designs of a target and then over targets; from a second fold of the same sequences with the confidence head on)unitless · higher
Uncertainty: Not reported by the source
Coverage: Not reported scored / Not reported eligible
Author-reported evaluation · Source checked Evidence concern: excluded from comparisons Appendix C states 'We do not claim zero sequence overlap between the training data and the evaluation panels', and Appendix G's homology screen is a coverage rule under which partial hits remain (Table 10: 28 of 74 de novo backbones and 7 of 12 pocket backbones have partial hits, and all 4 named enzymes are homologous to training data by design). Results on these panels are therefore not clean held-out measurements and must not be compared with results from sources that do establish no overlap.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix C 'Data and pool', final bullet; Appendix G 'Homology of the panels' and Table 10
The ten baselines are single published settings at one temperature each, so their design-set diversity differs from HyInv's: on CATH4.3 test HyInv samples at diversity 0.331 against 0.093 for PiFold, 0.104 for CMLM, 0.144 for LM-Design 650M and 0.000 for DPLM-2 3B, which decodes by argmax. Appendix D.2 states that these four differences are not at matched diversity, and Appendix A states that even for the closest baselines the comparisons are 'close to, but not exactly at, equal diversity', the largest offset of 0.016 being worth at most 0.0011 scTM at the development slope. The scTM and scTM difference results of the protocols named here must not be read as a matched-diversity ranking. The results read at a stated diversity level (Tables 8 and 9 and Appendix D.3) are not covered by this entry, because they are the ones the report reads on a fitted curve at a fixed diversity; nor are the recovery, diversity, pLDDT, scRMSD and lDDT results, whose protocols carry the same single-setting caveat in their own limitations and whose metric qualifiers say the value is at each method's own setting.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.1 and D.2; Table 7; Figure 14 diversity block; Section 5.1 'Baselines' and 'HyInv'
The inference-time results were measured with the supervised-stage weights and a rewrite temperature of 0.23, not with the released checkpoint and its default temperatures, and the quality read-outs of the two numerical paths used the RL checkpoint at update 288, not update 640. Speed and quality in this report are therefore measured on different weights, and the 57x figure compares HyInv's optimised BF16 path with ProteinMPNN's released implementation rather than with an equally optimised baseline.HyInv Technical Report (Hyra Team, 2026-10-14) · Table 1 footnote; Appendix F 'Timing protocol' and 'Baseline timings'
Methods, coverage and source HyInv on CATH4.3 test (pLDDT of ESMFold2 predictions of designed sequences, HyInv report)
hyinv-20261106-protocol-plddt-esmfold2
Aggregation: Not reported
HyInv Technical Report (Hyra Team, 2026-10-14) · Figure 15, 'pLDDT' block, row 'HyInv', column 'CATH4.3 test' (page 17 of 21) Configuration: HyInv default (HyInv report) Protocol: pLDDT of ESMFold2 predictions of designed sequences (HyInv report) Dataset: RecentPDB (121 chains from 111 recent PDB entries) 86.1 Plddt (ESMFold2 mean per-residue confidence over valid sites on a scale from 0 to 100, averaged over the designs of a target and then over targets; from a second fold of the same sequences with the confidence head on)unitless · higher
Uncertainty: Not reported by the source
Coverage: Not reported scored / Not reported eligible
Author-reported evaluation · Source checked Evidence concern: excluded from comparisons Appendix C states 'We do not claim zero sequence overlap between the training data and the evaluation panels', and Appendix G's homology screen is a coverage rule under which partial hits remain (Table 10: 28 of 74 de novo backbones and 7 of 12 pocket backbones have partial hits, and all 4 named enzymes are homologous to training data by design). Results on these panels are therefore not clean held-out measurements and must not be compared with results from sources that do establish no overlap.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix C 'Data and pool', final bullet; Appendix G 'Homology of the panels' and Table 10
The ten baselines are single published settings at one temperature each, so their design-set diversity differs from HyInv's: on CATH4.3 test HyInv samples at diversity 0.331 against 0.093 for PiFold, 0.104 for CMLM, 0.144 for LM-Design 650M and 0.000 for DPLM-2 3B, which decodes by argmax. Appendix D.2 states that these four differences are not at matched diversity, and Appendix A states that even for the closest baselines the comparisons are 'close to, but not exactly at, equal diversity', the largest offset of 0.016 being worth at most 0.0011 scTM at the development slope. The scTM and scTM difference results of the protocols named here must not be read as a matched-diversity ranking. The results read at a stated diversity level (Tables 8 and 9 and Appendix D.3) are not covered by this entry, because they are the ones the report reads on a fitted curve at a fixed diversity; nor are the recovery, diversity, pLDDT, scRMSD and lDDT results, whose protocols carry the same single-setting caveat in their own limitations and whose metric qualifiers say the value is at each method's own setting.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.1 and D.2; Table 7; Figure 14 diversity block; Section 5.1 'Baselines' and 'HyInv'
The inference-time results were measured with the supervised-stage weights and a rewrite temperature of 0.23, not with the released checkpoint and its default temperatures, and the quality read-outs of the two numerical paths used the RL checkpoint at update 288, not update 640. Speed and quality in this report are therefore measured on different weights, and the 57x figure compares HyInv's optimised BF16 path with ProteinMPNN's released implementation rather than with an equally optimised baseline.HyInv Technical Report (Hyra Team, 2026-10-14) · Table 1 footnote; Appendix F 'Timing protocol' and 'Baseline timings'
Methods, coverage and source HyInv on RecentPDB (pLDDT of ESMFold2 predictions of designed sequences, HyInv report)
hyinv-20261106-protocol-plddt-esmfold2
Aggregation: Not reported
HyInv Technical Report (Hyra Team, 2026-10-14) · Figure 15, 'pLDDT' block, row 'HyInv', column 'RecentPDB' (page 17 of 21) Configuration: HyInv default (HyInv report) Protocol: pLDDT of ESMFold2 predictions of designed sequences (HyInv report) Dataset: TS50 (50 chains) 86.5 Plddt (ESMFold2 mean per-residue confidence over valid sites on a scale from 0 to 100, averaged over the designs of a target and then over targets; from a second fold of the same sequences with the confidence head on)unitless · higher
Uncertainty: Not reported by the source
Coverage: Not reported scored / Not reported eligible
Author-reported evaluation · Source checked Evidence concern: excluded from comparisons Appendix C states 'We do not claim zero sequence overlap between the training data and the evaluation panels', and Appendix G's homology screen is a coverage rule under which partial hits remain (Table 10: 28 of 74 de novo backbones and 7 of 12 pocket backbones have partial hits, and all 4 named enzymes are homologous to training data by design). Results on these panels are therefore not clean held-out measurements and must not be compared with results from sources that do establish no overlap.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix C 'Data and pool', final bullet; Appendix G 'Homology of the panels' and Table 10
The ten baselines are single published settings at one temperature each, so their design-set diversity differs from HyInv's: on CATH4.3 test HyInv samples at diversity 0.331 against 0.093 for PiFold, 0.104 for CMLM, 0.144 for LM-Design 650M and 0.000 for DPLM-2 3B, which decodes by argmax. Appendix D.2 states that these four differences are not at matched diversity, and Appendix A states that even for the closest baselines the comparisons are 'close to, but not exactly at, equal diversity', the largest offset of 0.016 being worth at most 0.0011 scTM at the development slope. The scTM and scTM difference results of the protocols named here must not be read as a matched-diversity ranking. The results read at a stated diversity level (Tables 8 and 9 and Appendix D.3) are not covered by this entry, because they are the ones the report reads on a fitted curve at a fixed diversity; nor are the recovery, diversity, pLDDT, scRMSD and lDDT results, whose protocols carry the same single-setting caveat in their own limitations and whose metric qualifiers say the value is at each method's own setting.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.1 and D.2; Table 7; Figure 14 diversity block; Section 5.1 'Baselines' and 'HyInv'
The inference-time results were measured with the supervised-stage weights and a rewrite temperature of 0.23, not with the released checkpoint and its default temperatures, and the quality read-outs of the two numerical paths used the RL checkpoint at update 288, not update 640. Speed and quality in this report are therefore measured on different weights, and the 57x figure compares HyInv's optimised BF16 path with ProteinMPNN's released implementation rather than with an equally optimised baseline.HyInv Technical Report (Hyra Team, 2026-10-14) · Table 1 footnote; Appendix F 'Timing protocol' and 'Baseline timings'
Methods, coverage and source HyInv on TS50 (pLDDT of ESMFold2 predictions of designed sequences, HyInv report)
hyinv-20261106-protocol-plddt-esmfold2
Aggregation: Not reported
HyInv Technical Report (Hyra Team, 2026-10-14) · Figure 15, 'pLDDT' block, row 'HyInv', column 'TS50' (page 17 of 21) Configuration: HyInv default (HyInv report) Protocol: pLDDT of ESMFold2 predictions of designed sequences (HyInv report) Dataset: TS500 (500 chains) 90.6 Plddt (ESMFold2 mean per-residue confidence over valid sites on a scale from 0 to 100, averaged over the designs of a target and then over targets; from a second fold of the same sequences with the confidence head on)unitless · higher
Uncertainty: Not reported by the source
Coverage: Not reported scored / Not reported eligible
Author-reported evaluation · Source checked Evidence concern: excluded from comparisons Appendix C states 'We do not claim zero sequence overlap between the training data and the evaluation panels', and Appendix G's homology screen is a coverage rule under which partial hits remain (Table 10: 28 of 74 de novo backbones and 7 of 12 pocket backbones have partial hits, and all 4 named enzymes are homologous to training data by design). Results on these panels are therefore not clean held-out measurements and must not be compared with results from sources that do establish no overlap.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix C 'Data and pool', final bullet; Appendix G 'Homology of the panels' and Table 10
The ten baselines are single published settings at one temperature each, so their design-set diversity differs from HyInv's: on CATH4.3 test HyInv samples at diversity 0.331 against 0.093 for PiFold, 0.104 for CMLM, 0.144 for LM-Design 650M and 0.000 for DPLM-2 3B, which decodes by argmax. Appendix D.2 states that these four differences are not at matched diversity, and Appendix A states that even for the closest baselines the comparisons are 'close to, but not exactly at, equal diversity', the largest offset of 0.016 being worth at most 0.0011 scTM at the development slope. The scTM and scTM difference results of the protocols named here must not be read as a matched-diversity ranking. The results read at a stated diversity level (Tables 8 and 9 and Appendix D.3) are not covered by this entry, because they are the ones the report reads on a fitted curve at a fixed diversity; nor are the recovery, diversity, pLDDT, scRMSD and lDDT results, whose protocols carry the same single-setting caveat in their own limitations and whose metric qualifiers say the value is at each method's own setting.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.1 and D.2; Table 7; Figure 14 diversity block; Section 5.1 'Baselines' and 'HyInv'
The inference-time results were measured with the supervised-stage weights and a rewrite temperature of 0.23, not with the released checkpoint and its default temperatures, and the quality read-outs of the two numerical paths used the RL checkpoint at update 288, not update 640. Speed and quality in this report are therefore measured on different weights, and the 57x figure compares HyInv's optimised BF16 path with ProteinMPNN's released implementation rather than with an equally optimised baseline.HyInv Technical Report (Hyra Team, 2026-10-14) · Table 1 footnote; Appendix F 'Timing protocol' and 'Baseline timings'
Methods, coverage and source HyInv on TS500 (pLDDT of ESMFold2 predictions of designed sequences, HyInv report)
hyinv-20261106-protocol-plddt-esmfold2
Aggregation: Not reported
HyInv Technical Report (Hyra Team, 2026-10-14) · Figure 15, 'pLDDT' block, row 'HyInv', column 'TS500' (page 17 of 21) Configuration: HyInv default (HyInv report) Protocol: Self-consistency RMSD of designed sequences under ESMFold2 (HyInv report) Dataset: CATH4.2 test (1,120 chains) 3.64 Scrmsd (CA RMSD between the ESMFold2 prediction of a design and the native backbone at valid sites after optimal Kabsch superposition with the residue correspondence fixed by position, averaged over the designs of a target and then over targets)angstrom · lower
Uncertainty: Not reported by the source
Coverage: Not reported scored / Not reported eligible
Author-reported evaluation · Source checked Evidence concern: excluded from comparisons Appendix C states 'We do not claim zero sequence overlap between the training data and the evaluation panels', and Appendix G's homology screen is a coverage rule under which partial hits remain (Table 10: 28 of 74 de novo backbones and 7 of 12 pocket backbones have partial hits, and all 4 named enzymes are homologous to training data by design). Results on these panels are therefore not clean held-out measurements and must not be compared with results from sources that do establish no overlap.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix C 'Data and pool', final bullet; Appendix G 'Homology of the panels' and Table 10
The ten baselines are single published settings at one temperature each, so their design-set diversity differs from HyInv's: on CATH4.3 test HyInv samples at diversity 0.331 against 0.093 for PiFold, 0.104 for CMLM, 0.144 for LM-Design 650M and 0.000 for DPLM-2 3B, which decodes by argmax. Appendix D.2 states that these four differences are not at matched diversity, and Appendix A states that even for the closest baselines the comparisons are 'close to, but not exactly at, equal diversity', the largest offset of 0.016 being worth at most 0.0011 scTM at the development slope. The scTM and scTM difference results of the protocols named here must not be read as a matched-diversity ranking. The results read at a stated diversity level (Tables 8 and 9 and Appendix D.3) are not covered by this entry, because they are the ones the report reads on a fitted curve at a fixed diversity; nor are the recovery, diversity, pLDDT, scRMSD and lDDT results, whose protocols carry the same single-setting caveat in their own limitations and whose metric qualifiers say the value is at each method's own setting.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.1 and D.2; Table 7; Figure 14 diversity block; Section 5.1 'Baselines' and 'HyInv'
The inference-time results were measured with the supervised-stage weights and a rewrite temperature of 0.23, not with the released checkpoint and its default temperatures, and the quality read-outs of the two numerical paths used the RL checkpoint at update 288, not update 640. Speed and quality in this report are therefore measured on different weights, and the 57x figure compares HyInv's optimised BF16 path with ProteinMPNN's released implementation rather than with an equally optimised baseline.HyInv Technical Report (Hyra Team, 2026-10-14) · Table 1 footnote; Appendix F 'Timing protocol' and 'Baseline timings'
Methods, coverage and source HyInv on CATH4.2 test (Self-consistency RMSD of designed sequences under ESMFold2, HyInv report)
hyinv-20261106-protocol-scrmsd-esmfold2
Aggregation: Not reported
HyInv Technical Report (Hyra Team, 2026-10-14) · Figure 15, 'scRMSD' block, row 'HyInv', column 'CATH4.2 test' (page 17 of 21) Configuration: HyInv default (HyInv report) Protocol: Self-consistency RMSD of designed sequences under ESMFold2 (HyInv report) Dataset: CATH4.3 test (1,882 chains) 3.78 Scrmsd (CA RMSD between the ESMFold2 prediction of a design and the native backbone at valid sites after optimal Kabsch superposition with the residue correspondence fixed by position, averaged over the designs of a target and then over targets)angstrom · lower
Uncertainty: Not reported by the source
Coverage: Not reported scored / Not reported eligible
Author-reported evaluation · Source checked Evidence concern: excluded from comparisons Appendix C states 'We do not claim zero sequence overlap between the training data and the evaluation panels', and Appendix G's homology screen is a coverage rule under which partial hits remain (Table 10: 28 of 74 de novo backbones and 7 of 12 pocket backbones have partial hits, and all 4 named enzymes are homologous to training data by design). Results on these panels are therefore not clean held-out measurements and must not be compared with results from sources that do establish no overlap.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix C 'Data and pool', final bullet; Appendix G 'Homology of the panels' and Table 10
The ten baselines are single published settings at one temperature each, so their design-set diversity differs from HyInv's: on CATH4.3 test HyInv samples at diversity 0.331 against 0.093 for PiFold, 0.104 for CMLM, 0.144 for LM-Design 650M and 0.000 for DPLM-2 3B, which decodes by argmax. Appendix D.2 states that these four differences are not at matched diversity, and Appendix A states that even for the closest baselines the comparisons are 'close to, but not exactly at, equal diversity', the largest offset of 0.016 being worth at most 0.0011 scTM at the development slope. The scTM and scTM difference results of the protocols named here must not be read as a matched-diversity ranking. The results read at a stated diversity level (Tables 8 and 9 and Appendix D.3) are not covered by this entry, because they are the ones the report reads on a fitted curve at a fixed diversity; nor are the recovery, diversity, pLDDT, scRMSD and lDDT results, whose protocols carry the same single-setting caveat in their own limitations and whose metric qualifiers say the value is at each method's own setting.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.1 and D.2; Table 7; Figure 14 diversity block; Section 5.1 'Baselines' and 'HyInv'
The inference-time results were measured with the supervised-stage weights and a rewrite temperature of 0.23, not with the released checkpoint and its default temperatures, and the quality read-outs of the two numerical paths used the RL checkpoint at update 288, not update 640. Speed and quality in this report are therefore measured on different weights, and the 57x figure compares HyInv's optimised BF16 path with ProteinMPNN's released implementation rather than with an equally optimised baseline.HyInv Technical Report (Hyra Team, 2026-10-14) · Table 1 footnote; Appendix F 'Timing protocol' and 'Baseline timings'
Methods, coverage and source HyInv on CATH4.3 test (Self-consistency RMSD of designed sequences under ESMFold2, HyInv report)
hyinv-20261106-protocol-scrmsd-esmfold2
Aggregation: Not reported
HyInv Technical Report (Hyra Team, 2026-10-14) · Figure 15, 'scRMSD' block, row 'HyInv', column 'CATH4.3 test' (page 17 of 21) Configuration: HyInv default (HyInv report) Protocol: Self-consistency RMSD of designed sequences under ESMFold2 (HyInv report) Dataset: RecentPDB (121 chains from 111 recent PDB entries) 4.25 Scrmsd (CA RMSD between the ESMFold2 prediction of a design and the native backbone at valid sites after optimal Kabsch superposition with the residue correspondence fixed by position, averaged over the designs of a target and then over targets)angstrom · lower
Uncertainty: Not reported by the source
Coverage: Not reported scored / Not reported eligible
Author-reported evaluation · Source checked Evidence concern: excluded from comparisons Appendix C states 'We do not claim zero sequence overlap between the training data and the evaluation panels', and Appendix G's homology screen is a coverage rule under which partial hits remain (Table 10: 28 of 74 de novo backbones and 7 of 12 pocket backbones have partial hits, and all 4 named enzymes are homologous to training data by design). Results on these panels are therefore not clean held-out measurements and must not be compared with results from sources that do establish no overlap.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix C 'Data and pool', final bullet; Appendix G 'Homology of the panels' and Table 10
The ten baselines are single published settings at one temperature each, so their design-set diversity differs from HyInv's: on CATH4.3 test HyInv samples at diversity 0.331 against 0.093 for PiFold, 0.104 for CMLM, 0.144 for LM-Design 650M and 0.000 for DPLM-2 3B, which decodes by argmax. Appendix D.2 states that these four differences are not at matched diversity, and Appendix A states that even for the closest baselines the comparisons are 'close to, but not exactly at, equal diversity', the largest offset of 0.016 being worth at most 0.0011 scTM at the development slope. The scTM and scTM difference results of the protocols named here must not be read as a matched-diversity ranking. The results read at a stated diversity level (Tables 8 and 9 and Appendix D.3) are not covered by this entry, because they are the ones the report reads on a fitted curve at a fixed diversity; nor are the recovery, diversity, pLDDT, scRMSD and lDDT results, whose protocols carry the same single-setting caveat in their own limitations and whose metric qualifiers say the value is at each method's own setting.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.1 and D.2; Table 7; Figure 14 diversity block; Section 5.1 'Baselines' and 'HyInv'
The inference-time results were measured with the supervised-stage weights and a rewrite temperature of 0.23, not with the released checkpoint and its default temperatures, and the quality read-outs of the two numerical paths used the RL checkpoint at update 288, not update 640. Speed and quality in this report are therefore measured on different weights, and the 57x figure compares HyInv's optimised BF16 path with ProteinMPNN's released implementation rather than with an equally optimised baseline.HyInv Technical Report (Hyra Team, 2026-10-14) · Table 1 footnote; Appendix F 'Timing protocol' and 'Baseline timings'
Methods, coverage and source HyInv on RecentPDB (Self-consistency RMSD of designed sequences under ESMFold2, HyInv report)
hyinv-20261106-protocol-scrmsd-esmfold2
Aggregation: Not reported
HyInv Technical Report (Hyra Team, 2026-10-14) · Figure 15, 'scRMSD' block, row 'HyInv', column 'RecentPDB' (page 17 of 21) Configuration: HyInv default (HyInv report) Protocol: Self-consistency RMSD of designed sequences under ESMFold2 (HyInv report) Dataset: TS50 (50 chains) 2.08 Scrmsd (CA RMSD between the ESMFold2 prediction of a design and the native backbone at valid sites after optimal Kabsch superposition with the residue correspondence fixed by position, averaged over the designs of a target and then over targets)angstrom · lower
Uncertainty: Not reported by the source
Coverage: Not reported scored / Not reported eligible
Author-reported evaluation · Source checked Evidence concern: excluded from comparisons Appendix C states 'We do not claim zero sequence overlap between the training data and the evaluation panels', and Appendix G's homology screen is a coverage rule under which partial hits remain (Table 10: 28 of 74 de novo backbones and 7 of 12 pocket backbones have partial hits, and all 4 named enzymes are homologous to training data by design). Results on these panels are therefore not clean held-out measurements and must not be compared with results from sources that do establish no overlap.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix C 'Data and pool', final bullet; Appendix G 'Homology of the panels' and Table 10
The ten baselines are single published settings at one temperature each, so their design-set diversity differs from HyInv's: on CATH4.3 test HyInv samples at diversity 0.331 against 0.093 for PiFold, 0.104 for CMLM, 0.144 for LM-Design 650M and 0.000 for DPLM-2 3B, which decodes by argmax. Appendix D.2 states that these four differences are not at matched diversity, and Appendix A states that even for the closest baselines the comparisons are 'close to, but not exactly at, equal diversity', the largest offset of 0.016 being worth at most 0.0011 scTM at the development slope. The scTM and scTM difference results of the protocols named here must not be read as a matched-diversity ranking. The results read at a stated diversity level (Tables 8 and 9 and Appendix D.3) are not covered by this entry, because they are the ones the report reads on a fitted curve at a fixed diversity; nor are the recovery, diversity, pLDDT, scRMSD and lDDT results, whose protocols carry the same single-setting caveat in their own limitations and whose metric qualifiers say the value is at each method's own setting.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.1 and D.2; Table 7; Figure 14 diversity block; Section 5.1 'Baselines' and 'HyInv'
The inference-time results were measured with the supervised-stage weights and a rewrite temperature of 0.23, not with the released checkpoint and its default temperatures, and the quality read-outs of the two numerical paths used the RL checkpoint at update 288, not update 640. Speed and quality in this report are therefore measured on different weights, and the 57x figure compares HyInv's optimised BF16 path with ProteinMPNN's released implementation rather than with an equally optimised baseline.HyInv Technical Report (Hyra Team, 2026-10-14) · Table 1 footnote; Appendix F 'Timing protocol' and 'Baseline timings'
Methods, coverage and source HyInv on TS50 (Self-consistency RMSD of designed sequences under ESMFold2, HyInv report)
hyinv-20261106-protocol-scrmsd-esmfold2
Aggregation: Not reported
HyInv Technical Report (Hyra Team, 2026-10-14) · Figure 15, 'scRMSD' block, row 'HyInv', column 'TS50' (page 17 of 21) Configuration: HyInv default (HyInv report) Protocol: Self-consistency RMSD of designed sequences under ESMFold2 (HyInv report) Dataset: TS500 (500 chains) 3.8 Scrmsd (CA RMSD between the ESMFold2 prediction of a design and the native backbone at valid sites after optimal Kabsch superposition with the residue correspondence fixed by position, averaged over the designs of a target and then over targets)angstrom · lower
Uncertainty: Not reported by the source
Coverage: Not reported scored / Not reported eligible
Author-reported evaluation · Source checked Evidence concern: excluded from comparisons Appendix C states 'We do not claim zero sequence overlap between the training data and the evaluation panels', and Appendix G's homology screen is a coverage rule under which partial hits remain (Table 10: 28 of 74 de novo backbones and 7 of 12 pocket backbones have partial hits, and all 4 named enzymes are homologous to training data by design). Results on these panels are therefore not clean held-out measurements and must not be compared with results from sources that do establish no overlap.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix C 'Data and pool', final bullet; Appendix G 'Homology of the panels' and Table 10
The ten baselines are single published settings at one temperature each, so their design-set diversity differs from HyInv's: on CATH4.3 test HyInv samples at diversity 0.331 against 0.093 for PiFold, 0.104 for CMLM, 0.144 for LM-Design 650M and 0.000 for DPLM-2 3B, which decodes by argmax. Appendix D.2 states that these four differences are not at matched diversity, and Appendix A states that even for the closest baselines the comparisons are 'close to, but not exactly at, equal diversity', the largest offset of 0.016 being worth at most 0.0011 scTM at the development slope. The scTM and scTM difference results of the protocols named here must not be read as a matched-diversity ranking. The results read at a stated diversity level (Tables 8 and 9 and Appendix D.3) are not covered by this entry, because they are the ones the report reads on a fitted curve at a fixed diversity; nor are the recovery, diversity, pLDDT, scRMSD and lDDT results, whose protocols carry the same single-setting caveat in their own limitations and whose metric qualifiers say the value is at each method's own setting.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.1 and D.2; Table 7; Figure 14 diversity block; Section 5.1 'Baselines' and 'HyInv'
The inference-time results were measured with the supervised-stage weights and a rewrite temperature of 0.23, not with the released checkpoint and its default temperatures, and the quality read-outs of the two numerical paths used the RL checkpoint at update 288, not update 640. Speed and quality in this report are therefore measured on different weights, and the 57x figure compares HyInv's optimised BF16 path with ProteinMPNN's released implementation rather than with an equally optimised baseline.HyInv Technical Report (Hyra Team, 2026-10-14) · Table 1 footnote; Appendix F 'Timing protocol' and 'Baseline timings'
Methods, coverage and source HyInv on TS500 (Self-consistency RMSD of designed sequences under ESMFold2, HyInv report)
hyinv-20261106-protocol-scrmsd-esmfold2
Aggregation: Not reported
HyInv Technical Report (Hyra Team, 2026-10-14) · Figure 15, 'scRMSD' block, row 'HyInv', column 'TS500' (page 17 of 21) Configuration: HyInv default (HyInv report) Protocol: scTM of designed sequences under Boltz2 (HyInv report) Dataset: RecentPDB (121 chains from 111 recent PDB entries) 0.874 Sctm (Mean TM-score of the predicted structure to the native backbone, averaged over the designs of a target and then over targets; Boltz2 as the structure predictor, with the alignment built from the designed sequence by MMseqs2 against UniRef50; RecentPDB only)unitless · higher
Uncertainty: Not reported by the source
Coverage: Not reported scored / Not reported eligible
Author-reported evaluation · Source checked Evidence concern: excluded from comparisons Appendix C states 'We do not claim zero sequence overlap between the training data and the evaluation panels', and Appendix G's homology screen is a coverage rule under which partial hits remain (Table 10: 28 of 74 de novo backbones and 7 of 12 pocket backbones have partial hits, and all 4 named enzymes are homologous to training data by design). Results on these panels are therefore not clean held-out measurements and must not be compared with results from sources that do establish no overlap.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix C 'Data and pool', final bullet; Appendix G 'Homology of the panels' and Table 10
The ten baselines are single published settings at one temperature each, so their design-set diversity differs from HyInv's: on CATH4.3 test HyInv samples at diversity 0.331 against 0.093 for PiFold, 0.104 for CMLM, 0.144 for LM-Design 650M and 0.000 for DPLM-2 3B, which decodes by argmax. Appendix D.2 states that these four differences are not at matched diversity, and Appendix A states that even for the closest baselines the comparisons are 'close to, but not exactly at, equal diversity', the largest offset of 0.016 being worth at most 0.0011 scTM at the development slope. The scTM and scTM difference results of the protocols named here must not be read as a matched-diversity ranking. The results read at a stated diversity level (Tables 8 and 9 and Appendix D.3) are not covered by this entry, because they are the ones the report reads on a fitted curve at a fixed diversity; nor are the recovery, diversity, pLDDT, scRMSD and lDDT results, whose protocols carry the same single-setting caveat in their own limitations and whose metric qualifiers say the value is at each method's own setting.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.1 and D.2; Table 7; Figure 14 diversity block; Section 5.1 'Baselines' and 'HyInv'
The inference-time results were measured with the supervised-stage weights and a rewrite temperature of 0.23, not with the released checkpoint and its default temperatures, and the quality read-outs of the two numerical paths used the RL checkpoint at update 288, not update 640. Speed and quality in this report are therefore measured on different weights, and the 57x figure compares HyInv's optimised BF16 path with ProteinMPNN's released implementation rather than with an equally optimised baseline.HyInv Technical Report (Hyra Team, 2026-10-14) · Table 1 footnote; Appendix F 'Timing protocol' and 'Baseline timings'
Methods, coverage and source HyInv on RecentPDB Boltz2 (scTM of designed sequences under Boltz2, HyInv report)
hyinv-20261106-protocol-sctm-boltz2
Aggregation: Not reported
HyInv Technical Report (Hyra Team, 2026-10-14) · Table 6, row 'HyInv', column 'RecentPDB, Boltz2' (page 16 of 21) Configuration: HyInv default (HyInv report) Protocol: scTM of designed sequences under ESMFold2 (HyInv report) Dataset: CATH4.2 test (1,120 chains) 0.855 Sctm (Mean TM-score of the predicted structure to the native backbone, averaged over the designs of a target and then over targets (macro-average); computed on the CA trace at valid sites, normalised by the native length and clipped at one; ESMFold2 as the structure predictor, which is also the reinforcement-learning reward of HyInv)unitless · higher
Uncertainty: Not reported by the source
Coverage: Not reported scored / Not reported eligible
Author-reported evaluation · Source checked Evidence concern: excluded from comparisons Appendix C states 'We do not claim zero sequence overlap between the training data and the evaluation panels', and Appendix G's homology screen is a coverage rule under which partial hits remain (Table 10: 28 of 74 de novo backbones and 7 of 12 pocket backbones have partial hits, and all 4 named enzymes are homologous to training data by design). Results on these panels are therefore not clean held-out measurements and must not be compared with results from sources that do establish no overlap.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix C 'Data and pool', final bullet; Appendix G 'Homology of the panels' and Table 10
The ten baselines are single published settings at one temperature each, so their design-set diversity differs from HyInv's: on CATH4.3 test HyInv samples at diversity 0.331 against 0.093 for PiFold, 0.104 for CMLM, 0.144 for LM-Design 650M and 0.000 for DPLM-2 3B, which decodes by argmax. Appendix D.2 states that these four differences are not at matched diversity, and Appendix A states that even for the closest baselines the comparisons are 'close to, but not exactly at, equal diversity', the largest offset of 0.016 being worth at most 0.0011 scTM at the development slope. The scTM and scTM difference results of the protocols named here must not be read as a matched-diversity ranking. The results read at a stated diversity level (Tables 8 and 9 and Appendix D.3) are not covered by this entry, because they are the ones the report reads on a fitted curve at a fixed diversity; nor are the recovery, diversity, pLDDT, scRMSD and lDDT results, whose protocols carry the same single-setting caveat in their own limitations and whose metric qualifiers say the value is at each method's own setting.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.1 and D.2; Table 7; Figure 14 diversity block; Section 5.1 'Baselines' and 'HyInv'
The inference-time results were measured with the supervised-stage weights and a rewrite temperature of 0.23, not with the released checkpoint and its default temperatures, and the quality read-outs of the two numerical paths used the RL checkpoint at update 288, not update 640. Speed and quality in this report are therefore measured on different weights, and the 57x figure compares HyInv's optimised BF16 path with ProteinMPNN's released implementation rather than with an equally optimised baseline.HyInv Technical Report (Hyra Team, 2026-10-14) · Table 1 footnote; Appendix F 'Timing protocol' and 'Baseline timings'
Methods, coverage and source HyInv on CATH4.2 test (scTM of designed sequences under ESMFold2, HyInv report)
hyinv-20261106-protocol-sctm-esmfold2
Aggregation: Not reported
HyInv Technical Report (Hyra Team, 2026-10-14) · Table 6, row 'HyInv', column 'CATH4.2 test' (page 16 of 21) Configuration: HyInv default (HyInv report) Protocol: scTM of designed sequences under ESMFold2 (HyInv report) Dataset: CATH4.3 test (1,882 chains) 0.84 Sctm (Mean TM-score of the predicted structure to the native backbone, averaged over the designs of a target and then over targets (macro-average); computed on the CA trace at valid sites, normalised by the native length and clipped at one; ESMFold2 as the structure predictor, which is also the reinforcement-learning reward of HyInv)unitless · higher
Uncertainty: Not reported by the source
Coverage: Not reported scored / Not reported eligible
Author-reported evaluation · Source checked Evidence concern: excluded from comparisons Appendix C states 'We do not claim zero sequence overlap between the training data and the evaluation panels', and Appendix G's homology screen is a coverage rule under which partial hits remain (Table 10: 28 of 74 de novo backbones and 7 of 12 pocket backbones have partial hits, and all 4 named enzymes are homologous to training data by design). Results on these panels are therefore not clean held-out measurements and must not be compared with results from sources that do establish no overlap.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix C 'Data and pool', final bullet; Appendix G 'Homology of the panels' and Table 10
The ten baselines are single published settings at one temperature each, so their design-set diversity differs from HyInv's: on CATH4.3 test HyInv samples at diversity 0.331 against 0.093 for PiFold, 0.104 for CMLM, 0.144 for LM-Design 650M and 0.000 for DPLM-2 3B, which decodes by argmax. Appendix D.2 states that these four differences are not at matched diversity, and Appendix A states that even for the closest baselines the comparisons are 'close to, but not exactly at, equal diversity', the largest offset of 0.016 being worth at most 0.0011 scTM at the development slope. The scTM and scTM difference results of the protocols named here must not be read as a matched-diversity ranking. The results read at a stated diversity level (Tables 8 and 9 and Appendix D.3) are not covered by this entry, because they are the ones the report reads on a fitted curve at a fixed diversity; nor are the recovery, diversity, pLDDT, scRMSD and lDDT results, whose protocols carry the same single-setting caveat in their own limitations and whose metric qualifiers say the value is at each method's own setting.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.1 and D.2; Table 7; Figure 14 diversity block; Section 5.1 'Baselines' and 'HyInv'
The inference-time results were measured with the supervised-stage weights and a rewrite temperature of 0.23, not with the released checkpoint and its default temperatures, and the quality read-outs of the two numerical paths used the RL checkpoint at update 288, not update 640. Speed and quality in this report are therefore measured on different weights, and the 57x figure compares HyInv's optimised BF16 path with ProteinMPNN's released implementation rather than with an equally optimised baseline.HyInv Technical Report (Hyra Team, 2026-10-14) · Table 1 footnote; Appendix F 'Timing protocol' and 'Baseline timings'
Methods, coverage and source HyInv on CATH4.3 test (scTM of designed sequences under ESMFold2, HyInv report)
hyinv-20261106-protocol-sctm-esmfold2
Aggregation: Not reported
HyInv Technical Report (Hyra Team, 2026-10-14) · Table 6, row 'HyInv', column 'CATH4.3 test' (page 16 of 21) Configuration: HyInv default (HyInv report) Protocol: scTM of designed sequences under ESMFold2 (HyInv report) Dataset: RecentPDB (121 chains from 111 recent PDB entries) 0.861 Sctm (Mean TM-score of the predicted structure to the native backbone, averaged over the designs of a target and then over targets (macro-average); computed on the CA trace at valid sites, normalised by the native length and clipped at one; ESMFold2 as the structure predictor, which is also the reinforcement-learning reward of HyInv)unitless · higher
Uncertainty: Not reported by the source
Coverage: Not reported scored / Not reported eligible
Author-reported evaluation · Source checked Evidence concern: excluded from comparisons Appendix C states 'We do not claim zero sequence overlap between the training data and the evaluation panels', and Appendix G's homology screen is a coverage rule under which partial hits remain (Table 10: 28 of 74 de novo backbones and 7 of 12 pocket backbones have partial hits, and all 4 named enzymes are homologous to training data by design). Results on these panels are therefore not clean held-out measurements and must not be compared with results from sources that do establish no overlap.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix C 'Data and pool', final bullet; Appendix G 'Homology of the panels' and Table 10
The ten baselines are single published settings at one temperature each, so their design-set diversity differs from HyInv's: on CATH4.3 test HyInv samples at diversity 0.331 against 0.093 for PiFold, 0.104 for CMLM, 0.144 for LM-Design 650M and 0.000 for DPLM-2 3B, which decodes by argmax. Appendix D.2 states that these four differences are not at matched diversity, and Appendix A states that even for the closest baselines the comparisons are 'close to, but not exactly at, equal diversity', the largest offset of 0.016 being worth at most 0.0011 scTM at the development slope. The scTM and scTM difference results of the protocols named here must not be read as a matched-diversity ranking. The results read at a stated diversity level (Tables 8 and 9 and Appendix D.3) are not covered by this entry, because they are the ones the report reads on a fitted curve at a fixed diversity; nor are the recovery, diversity, pLDDT, scRMSD and lDDT results, whose protocols carry the same single-setting caveat in their own limitations and whose metric qualifiers say the value is at each method's own setting.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.1 and D.2; Table 7; Figure 14 diversity block; Section 5.1 'Baselines' and 'HyInv'
The inference-time results were measured with the supervised-stage weights and a rewrite temperature of 0.23, not with the released checkpoint and its default temperatures, and the quality read-outs of the two numerical paths used the RL checkpoint at update 288, not update 640. Speed and quality in this report are therefore measured on different weights, and the 57x figure compares HyInv's optimised BF16 path with ProteinMPNN's released implementation rather than with an equally optimised baseline.HyInv Technical Report (Hyra Team, 2026-10-14) · Table 1 footnote; Appendix F 'Timing protocol' and 'Baseline timings'
Methods, coverage and source HyInv on RecentPDB (scTM of designed sequences under ESMFold2, HyInv report)
hyinv-20261106-protocol-sctm-esmfold2
Aggregation: Not reported
HyInv Technical Report (Hyra Team, 2026-10-14) · Table 6, row 'HyInv', column 'RecentPDB' (page 16 of 21) Configuration: HyInv default (HyInv report) Protocol: scTM of designed sequences under ESMFold2 (HyInv report) Dataset: TS50 (50 chains) 0.92 Sctm (Mean TM-score of the predicted structure to the native backbone, averaged over the designs of a target and then over targets (macro-average); computed on the CA trace at valid sites, normalised by the native length and clipped at one; ESMFold2 as the structure predictor, which is also the reinforcement-learning reward of HyInv)unitless · higher
Uncertainty: Not reported by the source
Coverage: Not reported scored / Not reported eligible
Author-reported evaluation · Source checked Evidence concern: excluded from comparisons Appendix C states 'We do not claim zero sequence overlap between the training data and the evaluation panels', and Appendix G's homology screen is a coverage rule under which partial hits remain (Table 10: 28 of 74 de novo backbones and 7 of 12 pocket backbones have partial hits, and all 4 named enzymes are homologous to training data by design). Results on these panels are therefore not clean held-out measurements and must not be compared with results from sources that do establish no overlap.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix C 'Data and pool', final bullet; Appendix G 'Homology of the panels' and Table 10
The ten baselines are single published settings at one temperature each, so their design-set diversity differs from HyInv's: on CATH4.3 test HyInv samples at diversity 0.331 against 0.093 for PiFold, 0.104 for CMLM, 0.144 for LM-Design 650M and 0.000 for DPLM-2 3B, which decodes by argmax. Appendix D.2 states that these four differences are not at matched diversity, and Appendix A states that even for the closest baselines the comparisons are 'close to, but not exactly at, equal diversity', the largest offset of 0.016 being worth at most 0.0011 scTM at the development slope. The scTM and scTM difference results of the protocols named here must not be read as a matched-diversity ranking. The results read at a stated diversity level (Tables 8 and 9 and Appendix D.3) are not covered by this entry, because they are the ones the report reads on a fitted curve at a fixed diversity; nor are the recovery, diversity, pLDDT, scRMSD and lDDT results, whose protocols carry the same single-setting caveat in their own limitations and whose metric qualifiers say the value is at each method's own setting.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.1 and D.2; Table 7; Figure 14 diversity block; Section 5.1 'Baselines' and 'HyInv'
The inference-time results were measured with the supervised-stage weights and a rewrite temperature of 0.23, not with the released checkpoint and its default temperatures, and the quality read-outs of the two numerical paths used the RL checkpoint at update 288, not update 640. Speed and quality in this report are therefore measured on different weights, and the 57x figure compares HyInv's optimised BF16 path with ProteinMPNN's released implementation rather than with an equally optimised baseline.HyInv Technical Report (Hyra Team, 2026-10-14) · Table 1 footnote; Appendix F 'Timing protocol' and 'Baseline timings'
Methods, coverage and source HyInv on TS50 (scTM of designed sequences under ESMFold2, HyInv report)
hyinv-20261106-protocol-sctm-esmfold2
Aggregation: Not reported
HyInv Technical Report (Hyra Team, 2026-10-14) · Table 6, row 'HyInv', column 'TS50' (page 16 of 21) Configuration: HyInv default (HyInv report) Protocol: scTM of designed sequences under ESMFold2 (HyInv report) Dataset: TS500 (500 chains) 0.899 Sctm (Mean TM-score of the predicted structure to the native backbone, averaged over the designs of a target and then over targets (macro-average); computed on the CA trace at valid sites, normalised by the native length and clipped at one; ESMFold2 as the structure predictor, which is also the reinforcement-learning reward of HyInv)unitless · higher
Uncertainty: Not reported by the source
Coverage: Not reported scored / Not reported eligible
Author-reported evaluation · Source checked Evidence concern: excluded from comparisons Appendix C states 'We do not claim zero sequence overlap between the training data and the evaluation panels', and Appendix G's homology screen is a coverage rule under which partial hits remain (Table 10: 28 of 74 de novo backbones and 7 of 12 pocket backbones have partial hits, and all 4 named enzymes are homologous to training data by design). Results on these panels are therefore not clean held-out measurements and must not be compared with results from sources that do establish no overlap.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix C 'Data and pool', final bullet; Appendix G 'Homology of the panels' and Table 10
The ten baselines are single published settings at one temperature each, so their design-set diversity differs from HyInv's: on CATH4.3 test HyInv samples at diversity 0.331 against 0.093 for PiFold, 0.104 for CMLM, 0.144 for LM-Design 650M and 0.000 for DPLM-2 3B, which decodes by argmax. Appendix D.2 states that these four differences are not at matched diversity, and Appendix A states that even for the closest baselines the comparisons are 'close to, but not exactly at, equal diversity', the largest offset of 0.016 being worth at most 0.0011 scTM at the development slope. The scTM and scTM difference results of the protocols named here must not be read as a matched-diversity ranking. The results read at a stated diversity level (Tables 8 and 9 and Appendix D.3) are not covered by this entry, because they are the ones the report reads on a fitted curve at a fixed diversity; nor are the recovery, diversity, pLDDT, scRMSD and lDDT results, whose protocols carry the same single-setting caveat in their own limitations and whose metric qualifiers say the value is at each method's own setting.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.1 and D.2; Table 7; Figure 14 diversity block; Section 5.1 'Baselines' and 'HyInv'
The inference-time results were measured with the supervised-stage weights and a rewrite temperature of 0.23, not with the released checkpoint and its default temperatures, and the quality read-outs of the two numerical paths used the RL checkpoint at update 288, not update 640. Speed and quality in this report are therefore measured on different weights, and the 57x figure compares HyInv's optimised BF16 path with ProteinMPNN's released implementation rather than with an equally optimised baseline.HyInv Technical Report (Hyra Team, 2026-10-14) · Table 1 footnote; Appendix F 'Timing protocol' and 'Baseline timings'
Methods, coverage and source HyInv on TS500 (scTM of designed sequences under ESMFold2, HyInv report)
hyinv-20261106-protocol-sctm-esmfold2
Aggregation: Not reported
HyInv Technical Report (Hyra Team, 2026-10-14) · Table 6, row 'HyInv', column 'TS500' (page 16 of 21) Configuration: HyInv default (HyInv report) Protocol: HyInv above the ProteinMPNN temperature curve at HyInv's diversity (HyInv report) Dataset: CATH4.3 test (1,882 chains) +0.0146 [+0.0058, +0.0242] Sctm at fixed diversity difference (HyInv default minus the quadratic fit through ProteinMPNN's three temperatures read at the HyInv diversity, with a 95% interval over clusters; ESMFold2; the reference system is ProteinMPNN over its temperature grid; read at the diversity of the HyInv default setting on this panel The baseline side is read off that fitted curve rather than measured at a matched setting, and two of ProteinMPNN's three grid temperatures were generated for this report rather than taken from its published setting.)unitless · higher
Uncertainty: 95% CI +0.0058 to +0.0242. 95% intervals over clusters. The report does not state how many resamples this interval comes from.
Coverage: Not reported scored / Not reported eligible
Author-reported evaluation · Source checked Evidence concern: excluded from comparisons Appendix C states 'We do not claim zero sequence overlap between the training data and the evaluation panels', and Appendix G's homology screen is a coverage rule under which partial hits remain (Table 10: 28 of 74 de novo backbones and 7 of 12 pocket backbones have partial hits, and all 4 named enzymes are homologous to training data by design). Results on these panels are therefore not clean held-out measurements and must not be compared with results from sources that do establish no overlap.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix C 'Data and pool', final bullet; Appendix G 'Homology of the panels' and Table 10
The ten baselines are single published settings at one temperature each, so their design-set diversity differs from HyInv's: on CATH4.3 test HyInv samples at diversity 0.331 against 0.093 for PiFold, 0.104 for CMLM, 0.144 for LM-Design 650M and 0.000 for DPLM-2 3B, which decodes by argmax. Appendix D.2 states that these four differences are not at matched diversity, and Appendix A states that even for the closest baselines the comparisons are 'close to, but not exactly at, equal diversity', the largest offset of 0.016 being worth at most 0.0011 scTM at the development slope. The scTM and scTM difference results of the protocols named here must not be read as a matched-diversity ranking. The results read at a stated diversity level (Tables 8 and 9 and Appendix D.3) are not covered by this entry, because they are the ones the report reads on a fitted curve at a fixed diversity; nor are the recovery, diversity, pLDDT, scRMSD and lDDT results, whose protocols carry the same single-setting caveat in their own limitations and whose metric qualifiers say the value is at each method's own setting.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.1 and D.2; Table 7; Figure 14 diversity block; Section 5.1 'Baselines' and 'HyInv'
The inference-time results were measured with the supervised-stage weights and a rewrite temperature of 0.23, not with the released checkpoint and its default temperatures, and the quality read-outs of the two numerical paths used the RL checkpoint at update 288, not update 640. Speed and quality in this report are therefore measured on different weights, and the 57x figure compares HyInv's optimised BF16 path with ProteinMPNN's released implementation rather than with an equally optimised baseline.HyInv Technical Report (Hyra Team, 2026-10-14) · Table 1 footnote; Appendix F 'Timing protocol' and 'Baseline timings'
Methods, coverage and source HyInv above the ProteinMPNN curve at HyInv's diversity on CATH4.3 test (HyInv report)
hyinv-20261106-protocol-sctm-fixed-diversity-vs-proteinmpnn-curve
Aggregation: Not reported
HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.3 'scTM against diversity', sentence giving the reading on CATH4.3 test (page 15 of 21) Configuration: HyInv default (HyInv report) Protocol: HyInv above the ProteinMPNN temperature curve at HyInv's diversity (HyInv report) Dataset: RecentPDB (121 chains from 111 recent PDB entries) +0.0187 [+0.0078, +0.0302] Sctm at fixed diversity difference (HyInv default minus the quadratic fit through ProteinMPNN's three temperatures read at the HyInv diversity, with a 95% interval over clusters; ESMFold2; the reference system is ProteinMPNN over its temperature grid; read at the diversity of the HyInv default setting on this panel The baseline side is read off that fitted curve rather than measured at a matched setting, and two of ProteinMPNN's three grid temperatures were generated for this report rather than taken from its published setting.)unitless · higher
Uncertainty: 95% CI +0.0078 to +0.0302. 95% intervals over clusters. The report does not state how many resamples this interval comes from.
Coverage: Not reported scored / Not reported eligible
Author-reported evaluation · Source checked Evidence concern: excluded from comparisons Appendix C states 'We do not claim zero sequence overlap between the training data and the evaluation panels', and Appendix G's homology screen is a coverage rule under which partial hits remain (Table 10: 28 of 74 de novo backbones and 7 of 12 pocket backbones have partial hits, and all 4 named enzymes are homologous to training data by design). Results on these panels are therefore not clean held-out measurements and must not be compared with results from sources that do establish no overlap.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix C 'Data and pool', final bullet; Appendix G 'Homology of the panels' and Table 10
The ten baselines are single published settings at one temperature each, so their design-set diversity differs from HyInv's: on CATH4.3 test HyInv samples at diversity 0.331 against 0.093 for PiFold, 0.104 for CMLM, 0.144 for LM-Design 650M and 0.000 for DPLM-2 3B, which decodes by argmax. Appendix D.2 states that these four differences are not at matched diversity, and Appendix A states that even for the closest baselines the comparisons are 'close to, but not exactly at, equal diversity', the largest offset of 0.016 being worth at most 0.0011 scTM at the development slope. The scTM and scTM difference results of the protocols named here must not be read as a matched-diversity ranking. The results read at a stated diversity level (Tables 8 and 9 and Appendix D.3) are not covered by this entry, because they are the ones the report reads on a fitted curve at a fixed diversity; nor are the recovery, diversity, pLDDT, scRMSD and lDDT results, whose protocols carry the same single-setting caveat in their own limitations and whose metric qualifiers say the value is at each method's own setting.HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.1 and D.2; Table 7; Figure 14 diversity block; Section 5.1 'Baselines' and 'HyInv'
The inference-time results were measured with the supervised-stage weights and a rewrite temperature of 0.23, not with the released checkpoint and its default temperatures, and the quality read-outs of the two numerical paths used the RL checkpoint at update 288, not update 640. Speed and quality in this report are therefore measured on different weights, and the 57x figure compares HyInv's optimised BF16 path with ProteinMPNN's released implementation rather than with an equally optimised baseline.HyInv Technical Report (Hyra Team, 2026-10-14) · Table 1 footnote; Appendix F 'Timing protocol' and 'Baseline timings'
Methods, coverage and source HyInv above the ProteinMPNN curve at HyInv's diversity on RecentPDB (HyInv report)
hyinv-20261106-protocol-sctm-fixed-diversity-vs-proteinmpnn-curve
Aggregation: Not reported
HyInv Technical Report (Hyra Team, 2026-10-14) · Appendix D.3 'scTM against diversity', sentence giving the reading on RecentPDB (page 15 of 21)