rewirebio.iobenchmarks
Configuration

scPRINT (HyCell report)

Produces a frozen cell embedding with scPRINT as the HyCell report runs it.

12 evaluations · 12 results

Overview

An explanatory profile has not yet been reviewed for this record.

Consult the linked sources for architecture or protocol details. Missing evidence is not evidence of a missing capability.

Model Capabilities & Hardware Requirements

Deployment facts recorded for scPRINT (HyCell report). Fields the record does not carry are marked not recorded.

ParametersNot recorded
Minimum VRAMNot recorded
Inference LatencyNot recorded
Context WindowNot recorded
AccessNot recorded
LicenseNot recorded

Evaluated Checkpoint: Released weights at default inference settings; no revision printed

Evaluations and results

12 evaluations · 12 results. Different protocols are not a single leaderboard.

Sorted by Weighted composite score (S = 0.3 Bio + 0.2 Batch + 0.25 LR + 0.25 kNN, the authors' weighting, which gives the scIB total (0.6 Bio + 0.4 Batch) and annotation transfer equal weight; per atlas or averaged over the seven atlases) (higher is better). The best value in each column is highlighted. Decimals are rounded for display; each value links to the printed value and its source.

Tested configurationProtocol and datasetWeighted composite score (S = 0.3 Bio + 0.2 Batch + 0.25 LR + 0.25 kNN, the authors' weighting, which gives the scIB total (0.6 Bio + 0.4 Batch) and annotation transfer equal weight; per atlas or averaged over the seven atlases)Macro F1 (Macro-F1 of a 15-nearest-neighbour classifier trained on the other batches, over the cell types of the held-out batch, averaged over held-out batches; per atlas or averaged over the seven atlases)Macro F1 (Macro-F1 of a logistic-regression classifier trained on the other batches, over the cell types of the held-out batch, averaged over held-out batches; per atlas or averaged over the seven atlases)Scib batch correction score (Mean of five scIB batch-correction metrics (batch silhouette, iLISI, kBET, graph connectivity and principal-component regression), per atlas or averaged over the seven atlases)Scib bio conservation score (Mean of seven scIB biological-conservation metrics (isolated-label score, NMI and ARI of k-means and of Leiden clusters against the cell types, cell-type silhouette and cLISI), per atlas or averaged over the seven atlases)
scPRINT (HyCell report)EvaluationComposite score S (HyCell report), PBMC from two 10x Genomics runs (HyCell report)0.772 (best in column)Not reportedNot reportedNot reportedNot reported
scPRINT (HyCell report)EvaluationComposite score S (HyCell report), MultiVINE brain vasculature, healthy donors (HyCell report)0.661Not reportedNot reportedNot reportedNot reported
scPRINT (HyCell report)EvaluationComposite score S (HyCell report), scIB human immune atlas, integer-count part (HyCell report)0.642Not reportedNot reportedNot reportedNot reported
scPRINT (HyCell report)EvaluationComposite score S (HyCell report), scIB human lung atlas, integer-count part (HyCell report)0.609Not reportedNot reportedNot reportedNot reported
scPRINT (HyCell report)EvaluationComposite score S (HyCell report), Seven held-out atlases of the HyCell report0.607Not reportedNot reportedNot reportedNot reported
scPRINT (HyCell report)EvaluationComposite score S (HyCell report), scIB human pancreas atlas, integer-count part (HyCell report)0.54Not reportedNot reportedNot reportedNot reported
scPRINT (HyCell report)EvaluationComposite score S (HyCell report), Asian Immune Diversity Atlas, sample (HyCell report)0.532Not reportedNot reportedNot reportedNot reported
scPRINT (HyCell report)EvaluationComposite score S (HyCell report), Cross-tissue immune atlas, stratified sample (HyCell report)0.493Not reportedNot reportedNot reportedNot reported
scPRINT (HyCell report)EvaluationAnnotation transfer with 15-nearest neighbours (HyCell report), Seven held-out atlases of the HyCell reportNot reported0.678Not reportedNot reportedNot reported
scPRINT (HyCell report)EvaluationAnnotation transfer with logistic regression (HyCell report), Seven held-out atlases of the HyCell reportNot reportedNot reported0.781Not reportedNot reported
scPRINT (HyCell report)EvaluationscIB batch correction (HyCell report), Seven held-out atlases of the HyCell reportNot reportedNot reportedNot reported0.434Not reported
scPRINT (HyCell report)EvaluationscIB biological conservation (HyCell report), Seven held-out atlases of the HyCell reportNot reportedNot reportedNot reportedNot reported0.519
All 12 result rows with coverage, uncertainty and sources
Filter evaluations

Applied filters: All linked evaluations

Exact evaluated configurations and original reported results
Tested configurationProtocol and datasetFindingEvidence and details
Configuration: scPRINT (HyCell report)Protocol: Annotation transfer with 15-nearest neighbours (HyCell report)
Dataset: Seven held-out atlases of the HyCell report
0.678 Macro F1 (Macro-F1 of a 15-nearest-neighbour classifier trained on the other batches, over the cell types of the held-out batch, averaged over held-out batches; per atlas or averaged over the seven atlases)
fraction · higher

Uncertainty: Not reported by the source: No uncertainty is printed anywhere in the report.

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

scPRINT on annotation-transfer-knn, seven-held-out-atlases (HyCell report)

hycell-20261106-protocol-annotation-transfer-knn

Aggregation: Not reported

HyCell: a Compact Embedding Model for Single-Cell Transcriptomes (Hyra Team, 2026-11-01) · Table 3, row 'scPRINTl' (printed 'scPRINT' with superscript l, trained with cell-type labels), column 'kNN' (page 5 of 9)
Configuration: scPRINT (HyCell report)Protocol: Annotation transfer with logistic regression (HyCell report)
Dataset: Seven held-out atlases of the HyCell report
0.781 Macro F1 (Macro-F1 of a logistic-regression classifier trained on the other batches, over the cell types of the held-out batch, averaged over held-out batches; per atlas or averaged over the seven atlases)
fraction · higher

Uncertainty: Not reported by the source: No uncertainty is printed anywhere in the report.

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

scPRINT on annotation-transfer-lr, seven-held-out-atlases (HyCell report)

hycell-20261106-protocol-annotation-transfer-lr

Aggregation: Not reported

HyCell: a Compact Embedding Model for Single-Cell Transcriptomes (Hyra Team, 2026-11-01) · Table 3, row 'scPRINTl' (printed 'scPRINT' with superscript l, trained with cell-type labels), column 'LR' (page 5 of 9)
Configuration: scPRINT (HyCell report)Protocol: scIB batch correction (HyCell report)
Dataset: Seven held-out atlases of the HyCell report
0.434 Scib batch correction score (Mean of five scIB batch-correction metrics (batch silhouette, iLISI, kBET, graph connectivity and principal-component regression), per atlas or averaged over the seven atlases)
unitless · higher

Uncertainty: Not reported by the source: No uncertainty is printed anywhere in the report.

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

scPRINT on batch-correction, seven-held-out-atlases (HyCell report)

hycell-20261106-protocol-batch-correction

Aggregation: Not reported

HyCell: a Compact Embedding Model for Single-Cell Transcriptomes (Hyra Team, 2026-11-01) · Table 3, row 'scPRINTl' (printed 'scPRINT' with superscript l, trained with cell-type labels), column 'Batch' (page 5 of 9)
Configuration: scPRINT (HyCell report)Protocol: scIB biological conservation (HyCell report)
Dataset: Seven held-out atlases of the HyCell report
0.519 Scib bio conservation score (Mean of seven scIB biological-conservation metrics (isolated-label score, NMI and ARI of k-means and of Leiden clusters against the cell types, cell-type silhouette and cLISI), per atlas or averaged over the seven atlases)
unitless · higher

Uncertainty: Not reported by the source: No uncertainty is printed anywhere in the report.

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

scPRINT on bio-conservation, seven-held-out-atlases (HyCell report)

hycell-20261106-protocol-bio-conservation

Aggregation: Not reported

HyCell: a Compact Embedding Model for Single-Cell Transcriptomes (Hyra Team, 2026-11-01) · Table 3, row 'scPRINTl' (printed 'scPRINT' with superscript l, trained with cell-type labels), column 'Bio' (page 5 of 9)
Configuration: scPRINT (HyCell report)Protocol: Composite score S (HyCell report)
Dataset: Asian Immune Diversity Atlas, sample (HyCell report)
0.532 Weighted composite score (S = 0.3 Bio + 0.2 Batch + 0.25 LR + 0.25 kNN, the authors' weighting, which gives the scIB total (0.6 Bio + 0.4 Batch) and annotation transfer equal weight; per atlas or averaged over the seven atlases)
unitless · higher

Uncertainty: Not reported by the source: No uncertainty is printed anywhere in the report.

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

scPRINT on composite-score, aida (HyCell report)

hycell-20261106-protocol-composite-score

Aggregation: Not reported

HyCell: a Compact Embedding Model for Single-Cell Transcriptomes (Hyra Team, 2026-11-01) · Table 4, row 'scPRINTl' (printed 'scPRINT' with superscript l, trained with cell-type labels), column 'AIDA' (page 5 of 9)
Configuration: scPRINT (HyCell report)Protocol: Composite score S (HyCell report)
Dataset: MultiVINE brain vasculature, healthy donors (HyCell report)
0.661 Weighted composite score (S = 0.3 Bio + 0.2 Batch + 0.25 LR + 0.25 kNN, the authors' weighting, which gives the scIB total (0.6 Bio + 0.4 Batch) and annotation transfer equal weight; per atlas or averaged over the seven atlases)
unitless · higher

Uncertainty: Not reported by the source: No uncertainty is printed anywhere in the report.

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

scPRINT on composite-score, brain (HyCell report)

hycell-20261106-protocol-composite-score

Aggregation: Not reported

HyCell: a Compact Embedding Model for Single-Cell Transcriptomes (Hyra Team, 2026-11-01) · Table 4, row 'scPRINTl' (printed 'scPRINT' with superscript l, trained with cell-type labels), column 'Brain' (page 5 of 9)
Configuration: scPRINT (HyCell report)Protocol: Composite score S (HyCell report)
Dataset: Cross-tissue immune atlas, stratified sample (HyCell report)
0.493 Weighted composite score (S = 0.3 Bio + 0.2 Batch + 0.25 LR + 0.25 kNN, the authors' weighting, which gives the scIB total (0.6 Bio + 0.4 Batch) and annotation transfer equal weight; per atlas or averaged over the seven atlases)
unitless · higher

Uncertainty: Not reported by the source: No uncertainty is printed anywhere in the report.

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

scPRINT on composite-score, cross-tissue-immune (HyCell report)

hycell-20261106-protocol-composite-score

Aggregation: Not reported

HyCell: a Compact Embedding Model for Single-Cell Transcriptomes (Hyra Team, 2026-11-01) · Table 4, row 'scPRINTl' (printed 'scPRINT' with superscript l, trained with cell-type labels), column 'Cross-tissue' (page 5 of 9)
Configuration: scPRINT (HyCell report)Protocol: Composite score S (HyCell report)
Dataset: scIB human immune atlas, integer-count part (HyCell report)
0.642 Weighted composite score (S = 0.3 Bio + 0.2 Batch + 0.25 LR + 0.25 kNN, the authors' weighting, which gives the scIB total (0.6 Bio + 0.4 Batch) and annotation transfer equal weight; per atlas or averaged over the seven atlases)
unitless · higher

Uncertainty: Not reported by the source: No uncertainty is printed anywhere in the report.

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

scPRINT on composite-score, immune (HyCell report)

hycell-20261106-protocol-composite-score

Aggregation: Not reported

HyCell: a Compact Embedding Model for Single-Cell Transcriptomes (Hyra Team, 2026-11-01) · Table 4, row 'scPRINTl' (printed 'scPRINT' with superscript l, trained with cell-type labels), column 'Immune' (page 5 of 9)
Configuration: scPRINT (HyCell report)Protocol: Composite score S (HyCell report)
Dataset: scIB human lung atlas, integer-count part (HyCell report)
0.609 Weighted composite score (S = 0.3 Bio + 0.2 Batch + 0.25 LR + 0.25 kNN, the authors' weighting, which gives the scIB total (0.6 Bio + 0.4 Batch) and annotation transfer equal weight; per atlas or averaged over the seven atlases)
unitless · higher

Uncertainty: Not reported by the source: No uncertainty is printed anywhere in the report.

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

scPRINT on composite-score, lung (HyCell report)

hycell-20261106-protocol-composite-score

Aggregation: Not reported

HyCell: a Compact Embedding Model for Single-Cell Transcriptomes (Hyra Team, 2026-11-01) · Table 4, row 'scPRINTl' (printed 'scPRINT' with superscript l, trained with cell-type labels), column 'Lung' (page 5 of 9)
Configuration: scPRINT (HyCell report)Protocol: Composite score S (HyCell report)
Dataset: scIB human pancreas atlas, integer-count part (HyCell report)
0.54 Weighted composite score (S = 0.3 Bio + 0.2 Batch + 0.25 LR + 0.25 kNN, the authors' weighting, which gives the scIB total (0.6 Bio + 0.4 Batch) and annotation transfer equal weight; per atlas or averaged over the seven atlases)
unitless · higher

Uncertainty: Not reported by the source: No uncertainty is printed anywhere in the report.

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

scPRINT on composite-score, pancreas (HyCell report)

hycell-20261106-protocol-composite-score

Aggregation: Not reported

HyCell: a Compact Embedding Model for Single-Cell Transcriptomes (Hyra Team, 2026-11-01) · Table 4, row 'scPRINTl' (printed 'scPRINT' with superscript l, trained with cell-type labels), column 'Pancreas' (page 5 of 9)
Configuration: scPRINT (HyCell report)Protocol: Composite score S (HyCell report)
Dataset: PBMC from two 10x Genomics runs (HyCell report)
0.772 Weighted composite score (S = 0.3 Bio + 0.2 Batch + 0.25 LR + 0.25 kNN, the authors' weighting, which gives the scIB total (0.6 Bio + 0.4 Batch) and annotation transfer equal weight; per atlas or averaged over the seven atlases)
unitless · higher

Uncertainty: Not reported by the source: No uncertainty is printed anywhere in the report.

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

scPRINT on composite-score, pbmc (HyCell report)

hycell-20261106-protocol-composite-score

Aggregation: Not reported

HyCell: a Compact Embedding Model for Single-Cell Transcriptomes (Hyra Team, 2026-11-01) · Table 4, row 'scPRINTl' (printed 'scPRINT' with superscript l, trained with cell-type labels), column 'PBMC' (page 5 of 9)
Configuration: scPRINT (HyCell report)Protocol: Composite score S (HyCell report)
Dataset: Seven held-out atlases of the HyCell report
0.607 Weighted composite score (S = 0.3 Bio + 0.2 Batch + 0.25 LR + 0.25 kNN, the authors' weighting, which gives the scIB total (0.6 Bio + 0.4 Batch) and annotation transfer equal weight; per atlas or averaged over the seven atlases)
unitless · higher

Uncertainty: Not reported by the source: No uncertainty is printed anywhere in the report.

Coverage: Not reported scored / Not reported eligible

Author-reported evaluation · Source checked
Methods, coverage and source

scPRINT on composite-score, seven-held-out-atlases (HyCell report)

hycell-20261106-protocol-composite-score

Aggregation: Not reported

HyCell: a Compact Embedding Model for Single-Cell Transcriptomes (Hyra Team, 2026-11-01) · Table 3, row 'scPRINTl' (printed 'scPRINT' with superscript l, trained with cell-type labels), column 'Score S' (page 5 of 9)

Source checking is not independent reproduction. Release 2026-11-21-c8bea25e5abb.

Use this configuration

How it works, versions and access

Additional methodological details, versions and access terms have not yet been extracted into a structured profile for this configuration. Consult the linked sources and evaluation records below.

Evidence

Source checking verifies the cited claim or transcription. It does not establish independent reproduction.

Evidence table

Inspect claims, sources and review details

Trace each statement to its source and review. A context-only reference supports the record generally; it does not verify an individual field. Source checking does not reproduce an experiment.

One row per statement and cited source. Multiple citations are not independent evaluations. Shared locators are labelled explicitly.

0 evidence rows matching the loaded filters

Claims, original sources and review scope · Release 2026-11-21-c8bea25e5abb
Property and statementOriginal source and locationReview and provenance

No evidence rows match these filters. Choose another scope or clear the search.

Sources and history

Release 2026-11-21-c8bea25e5abb · Record review: source checked

1 source record and release historyDownload this release (gzip)
Technical metadata and record identifiers

Technical metadata for this record is tracked under stable ID hycell-20261106-config-scprint.

Source locator: Section 3.1 'Models'; Table 3

Related records

How to cite

scPRINT (HyCell report). Rewire biological model benchmark database, release 2026-11-21-c8bea25e5abb. https://benchmarks.rewirebio.io/database/configuration/hycell-20261106-config-scprint/

Release 2026-11-21-c8bea25e5abb. Rankings and values change between releases, so keep the release id in the citation. Cite the original publication as well for any value you reuse: each result links its source.

The compilation and annotations made by Rewire in this release are offered under CC BY 4.0; values and text taken from cited sources stay under the terms of those sources and are not covered by this licence. Data licence

Suggest a correction