rewirebio.iobenchmarks
Result

MAE (non-centered, computed per assay and averaged across assays weighted by compound count) of Boltz-2 ipTM as an affinity score on Four-target subset of the public FEP benchmark

N/A MAE (non-centered, computed per assay and averaged across assays weighted by compound count)

Methods

Tested configuration
Boltz-2 ipTM as an affinity score
Protocol
FEP+ benchmark four-target subset, affinity ranking and cost
Dataset
Four-target subset of the public FEP benchmark
Procedure
FEP+ benchmark four-target subset, affinity ranking and cost
Evaluation
Boltz-2 iptm on the FEP+ benchmark four-target subset
Coverage
Not reported scored / Not reported eligible
Uncertainty
Not reported by the source
Evidence
Author-reported evaluation · source checkedBoltz-2: Towards Accurate and Efficient Binding Affinity Prediction, supplementary appendix · Table 12, row "Boltz-2 iptm", column "MAE", sub-column "non-cent." (text-layer line 1707)

A source-checked result verifies the numerical transcription, not every model or protocol detail. Evaluation metadata: source checked. Source checked does not mean independently reproduced.

Reproduction

Split
Held-out affinity test set
Adaptation
Published model applied without retraining; the interface confidence is read in place of an affinity
Scoring implementation
Appendix D.2.2 'Evaluation metrics': Pearson R, Kendall tau, pairwise MAE (PMAE), MAE and the fraction of predictions within 1 and 2 kcal/mol, each computed per assay and averaged across assays weighted by compound count, with predictions converted to kcal/mol first; the centered variants translate each assay's predictions to the ground-truth mean

No execution recipe has been verified for this exact configuration and evaluation. A benchmark's general instructions may use different inputs, splits or model settings.

Reproducing this published result requires matching its model configuration, data, split and scorer. Source checking or a successful smoke test does not establish score reproduction.

Evidence

Source checking verifies the cited claim or transcription. It does not establish independent reproduction.

Evidence table

Inspect claims, sources and review details

Trace each statement to its source and review. A context-only reference supports the record generally; it does not verify an individual field. Source checking does not reproduce an experiment.

One row per statement and cited source. Multiple citations are not independent evaluations. Shared locators are labelled explicitly.

1 evidence row matching the loaded filters

Claims, original sources and review scope · Release 2026-10-22-1b7cf027e4f6
Property and statementOriginal source and locationReview and provenance
Reported result
N/A
Individual claims
Boltz-2: Towards Accurate and Efficient Binding Affinity Prediction, supplementary appendix

Original source ↗

Table 12, row "Boltz-2 iptm", column "MAE", sub-column "non-cent." (text-layer line 1707)

Version: bioRxiv v1 posted 2025-06-18; supplement PDF as deposited in Europe PMC PMC12262699 (PPR1038344)
Retrieved: 2026-10-22T11:52:00Z

source checked

["source-hash-verification","pdf-text-parse","independent-cell-check","rendered-source-visual-check","ai-assisted-source-review"] · 2026-10-22T13:40:00Z

author reported

Audit details

Independent review 2026-10-22: the printed value was re-read from the pinned artifact with a parser written for this review and matches, together with the numeric value, metric concept, qualifier, direction, unit, uncertainty, locator and the configuration, protocol and dataset the result hangs off. Cells the source prints as N/A or '-' carry no numeric value and a recorded reason.

Field: attributes.printed_value

Source artifact SHA-256: be867a5d92add8b223d47d882a4213ad489741f3e4d5081a0901a54370342569

Hash scope: The recorded hash is of the supplement PDF itself, extracted from the Europe PMC supplementaryFiles ZIP (ZIP SHA-256 25050dabd9c66fdb955704095023037f1bbabc3a93b7b61f00344c75df8bdb70 on 2026-10-22; the ZIP is rebuilt per request and its hash is not stable).

Archive member: NIHPP2025.06.14.659707v1-supplement-1.pdf

Inspected artifact

Extraction artifact SHA-256: be867a5d92add8b223d47d882a4213ad489741f3e4d5081a0901a54370342569

Extraction artifact

Sources and history

Release 2026-10-22-1b7cf027e4f6 · Record review: source checked

1 source record and release historyDownload this release (gzip)
Technical metadata and extraction receipts

Stable ID: uc-leadopt-20261022-result-t12-boltz-2-iptm-mae-non-centered

metric
mean-absolute-error
metric direction
lower
unit
kilocalorie-per-mole
printed value
N/A
source locator
Table 12, row "Boltz-2 iptm", column "MAE", sub-column "non-cent." (text-layer line 1707)
review
method: source-hash-verification; pdf-text-parse; independent-cell-check; rendered-source-visual-check; ai-assisted-source-review; method note: Re-retrieved all three sources and matched each pinned SHA-256. Re-rendered the Boltz-2 supplement with pdftotext -layout (poppler 26.08.0) and matched the text layer's recorded SHA-256. Re-read all 256 cells with a parser written for this review that does not import the extraction script, matching each result to its cell through its own source_locator, and separately read appendix tables 11, 12 and 14 from PNG renderings of PDF pages 29 and 30 at 160 dpi, and Ross Table 3 from the pinned XML markup. Checked printed value, numeric value, locator, metric concept, qualifier, direction, unit, uncertainty and the linked configuration, protocol and dataset, and that every N/A or '-' cell is recorded as missing with a reason.; reviewer: claude; reviewer note: Claude review agent, independent of the extraction agent; no human review claimed; reviewed at: 2026-10-22T13:40:00Z; artifact sha256: be867a5d92add8b223d47d882a4213ad489741f3e4d5081a0901a54370342569; retrieval url: https://www.ebi.ac.uk/europepmc/webservices/rest/PMC12262699/supplementaryFiles; note: Independent review 2026-10-22: the printed value was re-read from the pinned artifact with a parser written for this review and matches, together with the numeric value, metric concept, qualifier, direction, unit, uncertainty, locator and the configuration, protocol and dataset the result hangs off. Cells the source prints as N/A or '-' carry no numeric value and a recorded reason.
numeric value
Not reported
metric qualifier
non-centered, computed per assay and averaged across assays weighted by compound count
unit detail
Unit not printed in the table header; appendix D.2.2 states that all predictions are converted to kcal/mol before the metrics are computed
missing metadata
uncertainty: reason: unreported; value: reason: inapplicable; note: Printed as N/A. The source prints no value for this metric on this arm and does not say why; the arm either produces a score rather than an affinity in kcal/mol, or predicts only relative affinities, so the non-centered columns do not apply
Related records

Suggest a correction