rewirebio.iobenchmarks
Result

Ligand RMSD under 2a rate (ligand pose RMSD below 2 Angstrom, as reported in the cited literature; PoseBusters v2) of AutoDock Vina (LiPP evaluation) on PoseBusters v2 (308 protein-small molecule complexes)

60% Ligand RMSD under 2a rate (ligand pose RMSD below 2 Angstrom, as reported in the cited literature; PoseBusters v2)

Methods

Tested configuration
AutoDock Vina (LiPP evaluation)
Protocol
LiPP Table 2: lipid pose all-atom RMSD below 2 Angstrom, PoseBusters v2
Dataset
PoseBusters v2 (308 protein-small molecule complexes)
Procedure
LiPP Table 2: lipid pose all-atom RMSD below 2 Angstrom, PoseBusters v2
Evaluation
AutoDock Vina on PoseBusters v2 (lipid pose all-atom RMSD below 2 Angstrom)
Coverage
Not reported scored / Not reported eligible
Uncertainty
Not reported by the source
Evidence
Result quoted from another source · source checkedThe LiPP Benchmark Set for Modeling Lipid–Protein Complexes: Comparison of Co-Folding and Docking Methods · Table 2, row 'AutoDock Vina', column 'PoseBusters v2 (N = 308) % Success Rate'

A source-checked result verifies the numerical transcription, not every model or protocol detail. Evaluation metadata: source checked. Source checked does not mean independently reproduced.

Reproduction

Split
PoseBusters v2
Adaptation
None; tools run as released
Scoring implementation
lipid pose all-atom RMSD below 2 Angstrom

No execution recipe has been verified for this exact configuration and evaluation. A benchmark's general instructions may use different inputs, splits or model settings.

Reproducing this published result requires matching its model configuration, data, split and scorer. Source checking or a successful smoke test does not establish score reproduction.

Evidence

Source checking verifies the cited claim or transcription. It does not establish independent reproduction.

Evidence table

Inspect claims, sources and review details

Trace each statement to its source and review. A context-only reference supports the record generally; it does not verify an individual field. Source checking does not reproduce an experiment.

One row per statement and cited source. Multiple citations are not independent evaluations. Shared locators are labelled explicitly.

1 evidence row matching the loaded filters

Claims, original sources and review scope · Release 2026-10-22-1b7cf027e4f6
Property and statementOriginal source and locationReview and provenance
Reported result
60
Individual claims
The LiPP Benchmark Set for Modeling Lipid–Protein Complexes: Comparison of Co-Folding and Docking Methods

Original source ↗

Table 2, row 'AutoDock Vina', column 'PoseBusters v2 (N = 308) % Success Rate'

Version: PMC13292216.1
Retrieved: 2026-09-17T07:56:27.507412+00:00

source checked

["source-hash-verification","deterministic-table-parse","independent-cell-check"] · 2026-10-11

paper compilation

Audit details

Extraction: Parsed the pinned Europe PMC JATS XML with extract_lipp.py (table-wrap grid with rowspan and colspan expanded); row and column labels asserted. Table 2, row 'AutoDock Vina', column 'PoseBusters v2 (N = 308) % Success Rate' Independent review 2026-10-11: value, locator, metric, unit, direction and linked configuration and protocol checked; corrections from the review applied by the extractor as listed in review.md.

Field: attributes.printed_value

Source artifact SHA-256: 6ff34f2f709a14858a3753abf9f8f6efa1e7e3c351f15c70cf64264193a9414e

Hash scope: Exact retrieved primary paper artifact bytes.

Inspected artifact

Extraction artifact SHA-256: 6ff34f2f709a14858a3753abf9f8f6efa1e7e3c351f15c70cf64264193a9414e

Extraction artifact

Sources and history

Release 2026-10-22-1b7cf027e4f6 · Record review: source checked

1 source record and release historyDownload this release (gzip)
Technical metadata and extraction receipts

Stable ID: lit-structure-20261011-lipp-result-rmsd-posebusters-v2-308-autodock-vina

metric
ligand-rmsd-under-2a-rate
metric direction
higher
unit
percent
printed value
60
source locator
Table 2, row 'AutoDock Vina', column 'PoseBusters v2 (N = 308) % Success Rate'
review
method: source-hash-verification; deterministic-table-parse; independent-cell-check; method note: Reviewer re-retrieved the Europe PMC JATS XML and matched its SHA-256; an independent table-grid parse matched all 27 results and all 22 confidence intervals; a hand sample of all 27 values against the rendered PMC HTML matched.; reviewer: claude; reviewer note: Claude review agent reviewer-ps-2, independent of the extractor lit-protein-structure; no human review claimed; date: 2026-10-11; artifact sha256: 6ff34f2f709a14858a3753abf9f8f6efa1e7e3c351f15c70cf64264193a9414e; retrieval url: https://www.ebi.ac.uk/europepmc/webservices/rest/PMC13292216/fullTextXML; note: Extraction: Parsed the pinned Europe PMC JATS XML with extract_lipp.py (table-wrap grid with rowspan and colspan expanded); row and column labels asserted. Table 2, row 'AutoDock Vina', column 'PoseBusters v2 (N = 308) % Success Rate' Independent review 2026-10-11: value, locator, metric, unit, direction and linked configuration and protocol checked; corrections from the review applied by the extractor as listed in review.md.
numeric value
60
metric qualifier
ligand pose RMSD below 2 Angstrom, as reported in the cited literature; PoseBusters v2
missing metadata
uncertainty: reason: unreported
printed value basis
Percentage as printed
Related records

Suggest a correction