rewirebio.iobenchmarks
Result

Recall (Youden threshold from calibration set) of Evo2 (Youden) (Mathur and Sachidanandam 2026) on Mitochondrial variant test split, MITOMAP pathogenic and ClinGen/ClinVar benign (Mathur and Sachidanandam 2026)

0.867 Recall (Youden threshold from calibration set)

Methods

Tested configuration
Evo2 (Youden) (Mathur and Sachidanandam 2026)
Protocol
Mitochondrial variant pathogenicity classification (Mathur and Sachidanandam 2026 Table 2)
Dataset
Mitochondrial variant test split, MITOMAP pathogenic and ClinGen/ClinVar benign (Mathur and Sachidanandam 2026)
Procedure
Mitochondrial variant pathogenicity classification (Mathur and Sachidanandam 2026 Table 2)
Evaluation
Evo2 (Youden) on mtDNA pathogenicity test split
Coverage
Not reported scored / Not reported eligible
Uncertainty
Not reported by the source
Evidence
Independent external evaluation · source checkedBenchmarking DNA Foundation Models: Biological Blind Spots in Evo2 Variant-Effect Prediction · Table 2 (PDF page 10), row 'Evo2 (Youden)', column 'Sensitivity'

A source-checked result verifies the numerical transcription, not every model or protocol detail. Evaluation metadata: source checked. Source checked does not mean independently reproduced.

Reproduction

Split
30% test set
Adaptation
Zero-shot with calibrated threshold
Scoring implementation
Not reported

No execution recipe has been verified for this exact configuration and evaluation. A benchmark's general instructions may use different inputs, splits or model settings.

Reproducing this published result requires matching its model configuration, data, split and scorer. Source checking or a successful smoke test does not establish score reproduction.

Evidence

Source checking verifies the cited claim or transcription. It does not establish independent reproduction.

Evidence table

Inspect claims, sources and review details

Trace each statement to its source and review. A context-only reference supports the record generally; it does not verify an individual field. Source checking does not reproduce an experiment.

One row per statement and cited source. Multiple citations are not independent evaluations. Shared locators are labelled explicitly.

1 evidence row matching the loaded filters

Claims, original sources and review scope · Release 2026-11-21-c8bea25e5abb
Property and statementOriginal source and locationReview and provenance
Reported result
0.867
Individual claims
Benchmarking DNA Foundation Models: Biological Blind Spots in Evo2 Variant-Effect Prediction

Original source ↗

Table 2 (PDF page 10), row 'Evo2 (Youden)', column 'Sensitivity'

Version: bioRxiv preprint version 1, posted 2026-03-11
Retrieved: 2026-10-11T00:44:59Z

source checked

["source-hash-verification","pdf-text-parse","independent-cell-check"] · 2026-10-11

independent paper

Source has a recorded evidence concern. Consult its source page before using the claim.

Audit details

Extraction: Parsed the pdftotext -layout text of Table 2 (PDF page 10) with tools/extract_evo2mito.py; header and the eight row labels asserted. Independent review 2026-10-11: value, locator, metric, unit, direction and linked configuration and protocol checked; corrections from the review applied by the extractor as listed in review.md.

Field: attributes.printed_value

Source artifact SHA-256: 8fe2977a11335823be19474b350b65d6d436c7674e92e96f81c9086df0dacf7d

Hash scope: Hash scope not separately documented; inspect source record

Inspected artifact

Extraction artifact SHA-256: 8fe2977a11335823be19474b350b65d6d436c7674e92e96f81c9086df0dacf7d

Extraction artifact

Sources and history

Release 2026-11-21-c8bea25e5abb · Record review: source checked

1 source record and release historyDownload this release (gzip)
Technical metadata and extraction receipts

Stable ID: lit-genomics-20261011-evo2mito-result-evo2-youden-sensitivity

metric
recall
metric direction
higher
unit
fraction
printed value
0.867
source locator
Table 2 (PDF page 10), row 'Evo2 (Youden)', column 'Sensitivity'
review
method: source-hash-verification; pdf-text-parse; independent-cell-check; method note: Unpacked the archived PDF and matched its SHA-256; all values match Table 2 (PDF page 10) and the metric mapping is correct.; reviewer: claude; reviewer note: Claude review agent reviewer-gen-1, independent of the extractor lit-genomics; no human review claimed; date: 2026-10-11; artifact sha256: 8fe2977a11335823be19474b350b65d6d436c7674e92e96f81c9086df0dacf7d; retrieval url: https://www.biorxiv.org/content/10.64898/2026.03.10.710786v1.full.pdf; note: Extraction: Parsed the pdftotext -layout text of Table 2 (PDF page 10) with tools/extract_evo2mito.py; header and the eight row labels asserted. Independent review 2026-10-11: value, locator, metric, unit, direction and linked configuration and protocol checked; corrections from the review applied by the extractor as listed in review.md.
numeric value
0.867
metric qualifier
Youden threshold from calibration set
missing metadata
uncertainty: reason: unreported
Related records

Suggest a correction